Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings

Authors: Jack ConsoliniEric A. BognerMeghan SahrMatthew F. KoffKevin M. KochHollis G. Potter

Organizations: Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA

Abstract

Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement. Zero echo time (ZTE) MRI visualizes cortical bone and yields FAI angles that agree with CT, but automated angle extraction remains limited. We developed and validated automated FAI angle computation from ZTE MRI and assessed agreement with expert manual measurements in a cross-sectional study (level of evidence, 3). Pelvic ZTE MRI was acquired in 73 participants (mean age 36.8 +/- 18.5 years; 51 women, 22 men), yielding 135 hips. nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks. Custom geometric algorithms computed alpha, femoral neck-shaft, Tonnis, coronal and sagittal center-edge, and acetabular version angles from inferred segmentations. Measurements on 35 test hips were compared with the mean of two radiologists' manual measures using intraclass correlation (ICC) and Bland-Altman analysis. Dice exceeded 0.96 for bone and ranged from 0.65 to 0.83 for landmarks. Median landmark error was 0.38 mm (femoral head), 0.82 mm (lateral acetabulum), and <2.5 mm (medial acetabulum, greater trochanter). Interrater ICC was excellent for acetabular version, coronal center-edge, and Tonnis (>=0.82) but poor for alpha and femoral neck-shaft. Model versus rater-mean agreement was excellent for acetabular version, coronal center-edge, and Tonnis (0.92-0.96), good for mid-acetabular sagittal center-edge (0.74), and fair for alpha (0.45) and femoral neck-shaft (0.55). Model Bland-Altman limits of agreement were narrower than interrater limits for most angles. Fully automated morphometric assessment from ZTE MRI is feasible and performs comparably to expert readers for most coverage and version angles.

Explore similar work

Sep 9, 2026cs.CV

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6^\circ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.
Michael Wehrli, Leo Widmer, Edwin Li +5
May 9, 2026cs.CV

Reducing Annotation Burden for Femoral Cartilage Segmentation in Knee MRI via Cross-Sequence Transfer Learning

Purpose: To develop and evaluate cross-sequence transfer learning for automatic femoral cartilage segmentation, testing bidirectional transfer between dual-echo steady-state (DESS) and sagittal proton density-weighted 3D fast spin-echo (Cube) sequences. Materials and Methods: We optimized a modified 2D U-Net on 507 DESS images from the Osteoarthritis Initiative (OAI). We then established same-sequence baselines using subject-level cross-validation on a subset of 44 OAI DESS images and 44 Cube images acquired at the Istituto Ortopedico Rizzoli, Bologna, Italy. Each subset included 22 non-lesioned and 22 lesioned subjects. Finally, we performed transfer learning across sequences by fine-tuning the pretrained models on the target sequence with increasing training set sizes to study convergence, while keeping validation and test sets fixed. Segmentations were evaluated using Dice similarity coefficient (DSC) and average surface distance (ASD). Lesion effects were assessed with two-sided Mann-Whitney U tests with Bonferroni correction. Results: Same-sequence training yielded higher accuracy on DESS than Cube (DSC, 0.9000.900 vs 0.8300.830; P<.001P < .001). Cube-to-DESS transfer matched DESS performance (DSC, 0.903±0.0320.903 \pm 0.032 vs 0.900±0.0270.900 \pm 0.027), reaching a performance plateau at 9 training subjects. DESS-to-Cube yielded a lower combined DSC (0.802±0.0490.802 \pm 0.049 vs 0.830±0.0420.830 \pm 0.042), reaching a plateau at 24 training subjects. Lesions did not affect DESS (P.39P \ge .39) but reduced Cube accuracy (DSC, 0.8050.805 vs 0.8560.856; P<.001P < .001). Conclusion: Transfer learning across sequences can substantially reduce target-sequence annotation requirements for femoral cartilage segmentation, but performance is direction- and sequence-dependent, and the effects of lesions on segmentation may vary across MRI sequences.
Francesco Chiumento, Gianluigi Crimi, Elisa Moretta +7
Jun 3, 2026cs.CV

A New Angle on Bones: Robust Pose Estimation in X-Ray and Ultrasound

Measuring the angle between bone structures is a routine task in medical image analysis and provides a key quantitative parameter for diagnosis and treatment planning. Automated methods can reduce time and cost while improving reproducibility. In this work, we address automatic bone pose estimation using a learning-based point candidate proposal followed by a line model to extract axis parameters. Since conventional line models such as least squares are sensitive to outliers, we incorporate false-positive reduction strategies and robust fitting techniques, such as RANSAC and Hough transforms, to improve robustness. We evaluate our method on three clinically relevant paediatric angle estimation tasks: fracture fragment assessment in radiographs and ultrasound and developmental dysplasia of the hip evaluation in ultrasound using the Graf method. Our approach achieves mean errors of 4.14.1^\circ, 5.45.4^\circ, and 5.515.51^\circ, respectively, not only remaining within the expected clinical observer variability, but also significantly outperforming landmark-based methods. Our code and annotations for fracture angle assessment in radiographs are publicly available on GitHub.
Ron Keuth, Christoph Großbröhmer, Franziska Halm +5