cs.CVJun 30, 2026

Trust the Prior (or Not): Uncertainty-Aware Abdominal Aortic Aneurysm Segmentation

Authors: Erich RobbiDaniele RavanelliAndrea Passerini

Abstract

Robust segmentation of intraluminal thrombus is critical for risk assessment in Abdominal Aortic Aneurysm, yet it remains challenging due to heterogeneous thrombus features and low contrast with surrounding non-enhanced tissues. Domain shifts induced by different Computed Tomography Angiography (CTA) protocols further inhibit multi-center generalization of deep learning models. To address these challenges, we propose a patient-specific framework that integrates discriminative learning with anatomically informed priors. Our approach introduces two key components: (1) a patient-specific intensity normalization based on a Gaussian Mixture Model of local anatomy, and (2) an Uncertainty-Gated Anatomical Attention module that incorporates spatial priors while adaptively modulating their influence according to voxel-wise confidence. This design allows for anatomical guidance in ambiguous regions while suppressing unreliable priors. The proposed method achieves state-of-the-art performance on in-distribution test data and substantially outperforms existing alternatives in generalization to external multi-center CTA data, while remaining interpretable through an explicit separation of visual and anatomical evidence.

Explore similar work

Sep 2, 2026physics.med-ph

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.
Phillip Chlap, Mark Lee, Trevor Leong +11
Aug 12, 2026cs.CV

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.
Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou +6
Jul 6, 2026cs.CV

Shape Over Intensity: Directional Topological Encoding for False Positive Reduction in Intracranial Aneurysm Detection

Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates. Convolutional neural networks (CNNs) rely on local pixel intensities, causing systematic confusion between saccular aneurysms and vascular bifurcations - a problem especially acute for small lesions (<3 mm), where detection sensitivity falls below 60%. We propose a plug-and-play, topology-aware false-positive reduction framework evaluating the Smooth Euler Characteristic Transform (SECT) - a directional representation encoding global 3D vascular geometry independently of intensity - against persistence-based summaries (Persistence Images and Landscapes), tested on a stratified subset of the RSNA 2025 dataset. SECT achieves an AUC of 0.943, substantially outperforming direction-agnostic methods (AUC ~0.68), and exhibits a clinical performance inversion: it excels on the sub-3 mm cohort, maintaining 0.943 AUC and 78.5% sensitivity at 95% specificity. The representation is also scanner-agnostic, achieving 0.927 mean AUC under leave-one-scanner-out (LOGO) validation across four manufacturers. By capturing asymmetric geometric invariants rather than intensity profiles, SECT reliably resolves the primary structural confounder in IA detection, positioning it as a robust downstream filter for hybrid deep-learning diagnostic pipelines.
Akshay Gokhale, Mansi Dhamne