cs.CRJul 7, 2026

REAN: Reconstruction-aware ECG Anonymization Based on Privacy--Utility Orthogonality

Authors: Taerin KiSunghwan ParkJunyoung ParkJaewoo Lee

Organizations: Chung-Ang University Seoul, South Korea

Abstract

A shared electrocardiogram (ECG) is itself a biometric fingerprint that can re-identify a patient and reveal personal information. Recent ECG anonymizers transform the signal before sharing to reduce privacy leakage. However, existing methods still face a privacy--utility trade-off, in which preserving privacy often compromises utility while preserving utility reveals personal information. We propose \emph{REAN} (\emph{RE}construction-aware ECG \emph{AN}onymizer), a raw ECG signal anonymizer, to address this privacy--utility trade-off. REAN reconstructs the signal using a 1-D U-Net trained with losses from frozen privacy and utility classifiers to reduce privacy leakage while preserving utility. The privacy and utility gradients are near-orthogonal (\approx93.8^\circ), so reducing privacy leakage leaves utility almost unchanged. On four public PhysioNet databases, REAN achieves the strongest privacy--utility balance among raw ECG signal baselines. It drives re-identification to chance (0.96\to0.00), keeps arrhythmia macro-AUROC at the clean level (Clean 0.9982 vs.\ REAN 0.9991), and maintains re-identification protection under unseen privacy-classifier architectures.

Explore similar work

Sep 11, 2026cs.CR

Differentially Private EEG Feature Anonymization: A Privacy-Utility Case Study in Clinical Neurophysiology

Clinical electroencephalography (EEG) data are valuable for healthcare research and for developing artificial intelligence (AI)-based clinical decision-support systems, but EEG recordings and derived features may contain sensitive patient-specific information. This creates privacy risks when data are reused, analyzed, or shared across clinical and research environments. Conventional anonymization methods are often insufficient for high-dimensional biomedical signals, since removing direct identifiers does not necessarily prevent re-identification, linkage, or inference risks. At the same time, strong privacy protection may distort clinically relevant signal characteristics and reduce data utility. This paper studies subject-level differential privacy for protecting clinical EEG-derived feature representations using Gaussian and Laplace perturbations. The proposed framework considers three deployment scenarios: client-side anonymization, centralized server-side anonymization, and decentralized local training. Following EEG preprocessing and feature extraction, Gaussian and Laplace perturbations are applied to the resulting patient-level EEG feature representations. The Laplace experiments evaluate the implemented noise scales, while the scales required for formal full-vector calibration are derived separately. The effects of both perturbations are assessed using statistical utility measures and a downstream machine-learning-based utility check. The results show that differentially private perturbation can be integrated into EEG processing workflows, but the selected mechanism, privacy parameters, and sensitivity calibration strongly influence data utility. The study highlights the practical privacy-utility trade-off in DP-based EEG feature anonymization and the challenges of preserving downstream utility in small and imbalanced clinical EEG datasets.
Noman Sadiq, Mohsen Toorani
Jun 10, 2026cs.CR

Privacy-Preserving Federated Autoencoder for ECG Anomaly Detection on Edge Devices

Continuous electrocardiography (ECG) monitoring could surface rhythm abnormalities before they escalate into cardiovascular events. However, a deployable system must satisfy three requirements simultaneously: legal-grade privacy (GDPR, HIPAA), real-time inference on constrained edge hardware, and detection quality under non-IID cross-hospital data. We design and evaluate an end-to-end federated system addressing all three for unsupervised 12-lead ECG anomaly detection on PTB-XL dataset, combining three autoencoder families (VanillaAE, ConvAE, VAE), Flower-based federated averaging (FedAvg) across ten simulated hospitals, client-side differentially private SGD (DP-SGD) with a Rényi-DP accountant, and 8-bit integer (INT8) post-training quantization with Raspberry Pi 4 benchmarking. Our main contributions are: an empirical characterization of how these mechanisms compose, practical DP-specific recommendations, and technical and security insights for a clinically sensitive setting. Federated learning matches or exceeds the centralized baseline across all architectures (ConvAE federated area under the ROC curve, AUROC, 0.7820.782), and an ε\varepsilon sweep identifies ε=4\varepsilon=4 as the recommended clinical operating point. INT8 quantization roughly halves model size and cuts Pi 4 latency by up to 4444% with <0.12<0.12% AUROC loss. Crucially, DP and quantization penalties are empirically independent, so practitioners need not trade a strong privacy guarantee for a compact edge footprint. To our knowledge, this is the first system combining federated learning, formal (ε,δ)(\varepsilon,δ)-DP, unsupervised reconstruction-based detection, and quantized AArch64 deployment.
Kaan Arda Akyol, Jakub Kacper Szeląg, Aydin Abadi +9
May 2, 2026cs.LG

ECG-biometrics-bench: A Unified Framework for Reproducible Benchmarking of ECG Biometrics

Electrocardiogram (ECG) biometrics have emerged as a promising modality for continuous, liveness-aware authentication in wearable systems. However, many prior studies report overly optimistic results due to data leakage (e.g., random splits within the same session). To address this issue, we introduce ECG-biometrics-bench, a modular, reproducible benchmarking framework that standardizes preprocessing, segmentation, and evaluation across seven widely used public ECG datasets spanning clinical, ambulatory, and large-scale cohort settings. The framework supports both closed-set and open-set (i.e., subject-disjoint generalization in this work) evaluation, as well as progressively realistic protocols including cross-session and long-term temporal separation. To facilitate reproducible research in the community, the ECG-biometrics-bench repository will be made publicly accessible on GitHub upon the acceptance of this manuscript. Through a comprehensive multi-dataset analysis, we expose the Random Split Fallacy, demonstrating that intra-session evaluation protocols artificially inflate performance while masking severe degradation caused by temporal drift and unseen identities. Furthermore, by evaluating multiple architectures, including DeepECG, ResNet1D, and CNN-LSTM, we show that these failures are not model-specific but are likely inherent to current supervised feature-learning paradigms. Finally, we demonstrate that performance degradation due to temporal aging can be partially mitigated through a heavy enrollment, lightweight authentication strategy based on dynamic multi-session template fusion. These findings establish a more realistic baseline for ECG biometrics and highlight critical challenges that must be addressed for reliable real-world deployment.
Milad Parvan