cs.CVJul 7, 2026

MAC-XA: Multi-view Anatomy-Correspondence Fusion for Coronary Stenosis Reporting from X-ray Angiography

Authors: Chen JiaBaochang ZhangFatia Kusuma DewiAmir YousefiHeribert SchunkertReza GhotbiNassir Navab

Organizations: Computer Aided Medical Procedures, Technical University of Munich, Munich, Germany · relAI – Konrad Zuse School of Excellence in Reliable AI, Munich, Germany · German Heart Center Munich, Munich, Germany · Munich Center for Machine Learning, Munich, Germany · German Centre for Cardiovascular Research, Munich Heart Alliance, Munich, Germany · HELIOS Hospital West of Munich, Munich, Germany

Abstract

Multi-view reasoning in coronary X-ray angiography is inherently a cross-projection geometric problem, yet automated report generation in this setting remains largely unexplored. The 3D vascular topology leads to projection-dependent branch overlap and foreshortening, rendering single-view modeling fundamentally incomplete and unstable for lesion localization and stenosis grading. Although multi-view fusion appears promising, learning anatomically consistent fusion from real angiograms is impeded by a critical limitation: cross-view alignment is unobservable and cannot be explicitly supervised. Consequently, conventional fusion relies on implicit correlations rather than verified anatomical correspondence. We address this by reformulating multi-view stenosis reporting as an alignment-constrained aggregation problem. A controllable synthetic angiography generation strategy is introduced to expose geometry-derived patch-level correspondence supervision unavailable in real data. An anatomy-correspondence module learns cross-view correspondence matrices that explicitly align auxiliary features within the main-view coordinate space prior to fusion, thereby constraining evidence aggregation to anatomically consistent regions. Experiments on synthetic data and zero-shot transfer to real angiograms show that this alignment-constrained design improves correspondence consistency and structured stenosis reporting compared to single-view modeling and conventional multi-view fusion methods. The code will be publicly available upon publication.

Explore similar work

Jun 26, 2026eess.IV

Anatomy-Grounded Synthetic Coronary Angiography for Geometry-Informed Multi-View Matching

Accurate correspondence matching across multiple angiographic views is the prerequisite for 3D coronary reconstruction and interventional guidance. However, the development of robust deep learning models for this task has been stifled by a fundamental data bottleneck. Obtaining ground truth for matching tasks in angiography pairs is prohibitively expensive and hard to scale. To overcome this barrier, we introduce a physically-grounded data generation framework that synthesizes high-fidelity Digital Reconstructed Radiographs (DRRs) from 3D Coronary CT Angiography (CCTA) volumes. Our framework generates dense, highly accurate 3D-to-2D projection labels by simulating realistic C-arm acquisition geometry on patient anatomy at zero human cost. Leveraging this dense supervision, we propose a Geometry-Informed Matching Module (GIMM) that integrates global feature and anatomical structure into correspondence learning. Unlike real angiography where assessment relies on subjective human annotation, our dataset provides 2D correspondence labels with paired images, allowing human-free evaluation. We comprehensively evaluate our method on the proposed CT-derived DRR dataset and demonstrate improvements over other matching baseline models.
In Kyu Lee, Sumin Seo, Jaesik Min
Sep 20, 2026cs.CV

Modeling Clinical Workflow for SYNTAX Scoring from Coronary Angiography Videos

The SYNTAX score is a clinically established tool for assessing anatomical lesion complexity in coronary artery disease and guiding subsequent treatment. However, automated SYNTAX scoring is commonly formulated as a direct regression problem from coronary angiography videos to patient-level scores. In this work, we reformulate SYNTAX scoring as a vessel segment identity-preserving anatomical reasoning problem and propose a hierarchical modeling framework that explicitly aligns learning with the clinical workflow. Our approach maintains vessel segment identity across frames and views, estimates stenosis severity at the segment level, and aggregates evidence hierarchically according to coronary anatomy. Simultaneously, to address the scarcity of domain-specific data, we integrate and complete multiple public coronary angiography datasets, constructing a large-scale resource featuring completed vessel segmentation and derived structural annotations. Experiments demonstrate that vessel segment-level stenosis embedding enhances explanatory power and reduces prediction variability compared to baseline models, with the R^2 score improving by 0.201 and dev STD decreasing by 18.4%. These results highlight the necessity of structure-aligned modeling for reliable and stable automated SYNTAX scoring from multi-view coronary angiography videos. The GitHub link is https://github.com/VersaceSu7/SYNTAX_score_777.
Suzhong Fu, Jingqi Dong, Xuan Ding +4
Sep 14, 2026cs.CG

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.
Deyu Meng, Mojtaba Lashgari, Yiying Wang +1