eess.IVJul 9, 2026

Calibrated Hybrid CNN-Transformer for Retinal OCT Classification

Authors: Animesh Kumar

Organizations: School of Computing, Newcastle University, UK

Abstract

Deep models for retinal optical coherence tomography (OCT) classification report high accuracy but rarely report whether their confidence can be trusted -- a gap that matters when a wrong-but-confident reading delays sight-saving treatment. We pair a hybrid convolutional-Transformer encoder with a gradient-boosting (XGBoost) classification head and a three-part clinical safety layer: confidence calibration, out-of-distribution (OOD) rejection, and per-prediction uncertainty flagging. On four-class OCT (84,495 scans) the model reaches 95.4% accuracy while cutting calibration error twelve-fold (expected calibration error, ECE = 0.0024), so the confidence it reports tracks its true accuracy. To our knowledge this is the first OCT classifier to validate all three safety mechanisms jointly, with public weights and reproducible multi-seed evaluation.

Explore similar work

Jul 9, 2026eess.IV

Uncertainty-Aware Multi-Source Retinal Fluid Segmentation in OCT

Measuring retinal fluid from optical coherence tomography (OCT) drives treatment decisions in macular disease, but manual annotation is slow and segmentation models trained on one scanner degrade on another. We present an attention-guided TransUNet that segments three fluid types across four independent OCT sources, combining a domain-adaptive normalisation scheme with an uncertainty estimate that flags unreliable pixels. The model reaches a mean fluid Dice of 0.78, and -- most usefully for clinicians -- its uncertainty is 1.34x higher exactly where expert graders disagree (p<10^-4), turning a raw segmentation map into an actionable clinical triage signal.
Animesh Kumar
May 4, 2026cs.CV

Representation learning from OCT images

Optical Coherence Tomography (OCT) has become one of the most used imaging modality in ophthalmology. It provides high-resolution, non-invasive visualization of retinal microarchitecture. The automated analysis of OCT images through representation learning has emerged as a central research frontier. This has mainly been driven by the clinical need to process large acquisition volumes. The objective is to reduce the reliance on expert annotation, and improve diagnostic consistency across devices and populations. This survey provides a comprehensive and structured review of representation learning methods for retinal OCT image analysis. It covers the period from early deep learning approaches to the most recent developments in foundation models and vision-language systems. We organize the literature along a principled taxonomy of learning paradigms, encompassing supervised learning with CNN-based and transformer-based architectures, self-supervised and semi-supervised methods, generative approaches, as well as 3D volumetric modeling, multimodal representation learning, and large-scale pretrained foundation models. For each paradigm, we analyze the core methodological contributions, identify persistent limitations, and trace the connections between successive approaches. We further provide a structured overview of publicly available OCT datasets, discuss evaluation protocol considerations, and present a unified problem formulation that situates each learning paradigm within a common mathematical framework. Building on this analysis, we identify and discuss the most pressing open research directions emerging in the literature. This includes volumetric foundation model pretraining, uncertainty-aware representation learning, federated and privacy-preserving training, fairness and bias mitigation, concept-based interpretability,...
Hedi Tabia, Désiré Sidibé, Nawres Khlifa +6
Jul 4, 2026eess.IV

Cross-Modal Fusion of OCT and OCT angiography enface for Improved Diagnostics of Diabetic Retinopathy

Diabetic retinopathy (DR) is a leading cause of vision impairment worldwide, highlighting the need for accurate and accessible screening tools. Optical Coherence Tomography (OCT) provides high-resolution structural information of the retina, whereas OCT angiography (OCTA) offers complementary vascular information that is highly relevant for DR diagnosis. In this study, we propose a cross-modal fusion of OCT B-scans with single-channel en face OCTA using a bidirectional cross-modal attention network for automated DR classification. Two independent datasets, OCT500 and UIC, comprising 730 subjects in total, were utilized to evaluate performance under within-dataset, combined-dataset, and cross-dataset generalization settings. A ConvNeXt V2 model trained solely on OCT images served as the unimodal baseline. In addition to ground-truth (GT) OCTA, we explored the use of translated (TR) OCTA generated from OCT scans, eliminating the requirement for dedicated OCTA hardware. Experimental results demonstrate that cross-modal fusion consistently outperforms unimodal OCT classification across all evaluation scenarios. Fusion with GT OCTA improved classification accuracy and discriminative performance, while TR OCTA achieved comparable or superior results in most settings. Furthermore, TR OCTA improved sensitivity and cross-dataset generalization, indicating enhanced robustness to domain shifts. These findings demonstrate that attention-based OCT-OCTA en face fusion provides clinically meaningful improvements for DR detection and suggest that computationally generated OCTA can serve as a practical, low-cost alternative to hardware-acquired OCTA, enabling broader deployment of high-performance retinal screening systems in resource-limited clinical environments.
Rashadul Hasan Badhon, Atalie Carina Thompson, Jennifer I. Lim +2