Information-seeking failures of large language models in agentic clinical reasoning
Authors: Krischan Braitsch, Laura K. Schmalbrock, Theresa Weltermann, Andrew F. Berdel, Isabella Miller, Kai Tran, Michael Heider, Sabrina Kraus, +6 more
Large language models achieve high scores on medical knowledge assessments, yet clinical reasoning requires actively deciding what to investigate under uncertainty. We developed an agentic evaluation framework in hematologic oncology in which models must proactively request clinical data across three sequential rounds before committing to a diagnosis and treatment plan. Across 32 frontier models, the best achieved only 68% overall accuracy. Information utilization, the fraction of available data actually requested, was the strongest predictor of diagnostic accuracy (R = 0.69, P < 0.001), yet utilization collapsed from 57% to 26% in the final round, leaving molecular and cytogenetic data critical for treatment selection unexamined. Reasoning traces scored high on a clinical reasoning rubric (91% above threshold) but decorrelated from accuracy, revealing a gap between locally coherent rationales and globally correct conclusions. Error analysis identified search satisficing, anchoring and premature closure as the dominant failure modes, the same cognitive biases that characterize novice clinicians under dual-process models of diagnostic reasoning. These findings demonstrate that the primary limitation of current models in clinical oncology is not insufficient medical knowledge but a systematic failure of information-seeking under uncertainty.
Large language models perform well on static medical examinations, yet clinical diagnosis often requires iterative evidence gathering under uncertainty. Building on prior interactive evaluation efforts, we introduce an OSCE-inspired standardized patient simulator and a controlled, reproducible benchmark for active diagnostic inquiry. Across 468 cases and 15 models in our protocol, we observe that multi-turn evidence seeking reduces diagnostic accuracy by 12.75% and lowers supporting-evidence quality by 24.36% relative to full-context evaluation; error analyses associate these drops with premature diagnostic closure and inefficient questioning. Together, these results suggest that static full-context benchmarks may overestimate performance in interactive evidence-seeking settings, motivating complementary interactive assessment for safer clinical decision support.
Large Language Models (LLMs) achieve strong results on many medical benchmarks, but their clinical reasoning remains difficult to evaluate reliably. A central risk is an evaluation illusion: fluent and well-structured explanations can appear clinically convincing even when the final diagnosis is incorrect. We introduce CLExEval, a human-in-the-loop framework for evaluating LLM clinical reasoning under progressive information masking. CLExEval combines 5,600 expert-physician annotations with 200 clinical reasoning traces derived from 40 rare diagnostic cases. Our analysis identifies three recurring failure patterns: (i) verbosity bias, where GPT-4o-mini's diagnostic accuracy drops from 95.0% to 32.5% under information scarcity; (ii) a hidden knowledge paradox, where a specialist model reaches 92.5% maximum diagnostic potential but fails to retrieve that knowledge reliably in verbose contexts; and (iii) a 68.6% reasoning-to-output mismatch, where correct diagnoses appear in reasoning traces but are not reflected in final answers. We further evaluate the LLM-as-a-Judge paradigm on a human-verified failure set (n = 142). GPT-4o-mini approved 47.9% of clinically incorrect outputs, while HuatuoGPT-o1 approved all validly scored failures and showed a positive self-preference bias. These results suggest that standalone automated clinical evaluations can substantially overestimate clinical reliability without expert-grounded validation.
Large language models (LLMs) are increasingly being explored for clinical decision support, but their reliability in complex oncology treatment planning remains unclear. We evaluated agentic LLM systems for breast cancer treatment recommendation generation using 72 real clinical cases across stages I to IV and 1,147 case-specific rubrics generated through Asymmetric Information Rubric Generation (AIRG), in which the rubric generator had access to real clinical decisions unavailable to the evaluated models. Seven pipelines were compared, including single-LLM baselines, tool-augmented systems, and multi-agent architectures with fact checking and autonomous subagent spawning. The best-performing configuration, Claude Opus 4.8 with the D&C+SA pipeline, achieved a global score of 0.594 ± 0.025. Tool use and increased agent autonomy had mixed effects, improving performance in some settings but degrading it in others. Performance varied by clinical domain and disease stage, and oncologist-led error analysis revealed persistent clinically relevant failures, including incorrect or missing recommendations, flawed justifications, citation errors, outdated claims, and overconfidence. These findings suggest that agentic LLM systems can generate clinically relevant breast cancer recommendations, but remain insufficient for unsupervised clinical use.
Vinicius Anjos de Almeida, Nícolas Henrique Borges, Leonardo Vicenzi +5