Projection-Domain Sensitivity Analysis of Vertebral DRRs Under Intrinsic Calibration Perturbation

Authors: Lin LiChaochao ZhouBenjamin AubertJunlin GuoJunchao Zhu

Organizations: Department of Mathematics, Tulane University · Department of Computer Science, University of Illinois Urbana-Champaign · EOS, EOS Imaging Inc. · Department of Electrical and Computer Engineering, Vanderbilt University · Department of Computer Science, Vanderbilt University

Abstract

Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration. Although calibration quality is typically evaluated using reconstruction-based metrics such as reprojection error, its influence on projection-domain consistency remains poorly understood. This study presents a synthetic framework for evaluating how intrinsic calibration perturbations affect vertebral fluoroscopic projections and downstream registration performance. CT-derived vertebral models and controlled cone-beam imaging geometry were used to generate DRRs with both ground-truth and perturbed intrinsic calibration parameters while maintaining identical anatomy and acquisition pose. Projection-domain changes were quantified using anatomical landmark displacement, contour distance, silhouette overlap, image similarity, and landmark-based 2D--3D registration accuracy in anterior--posterior (AP) and lateral (LAT) views. Results show that even small intrinsic calibration perturbations produce measurable changes in vertebral projection geometry, contour morphology, landmark localization, and DRR appearance. Sensitivity is strongly view dependent, with LAT projections exhibiting substantially greater deformation and anatomical displacement than AP projections. These projection inconsistencies also degrade downstream 2D--3D registration, particularly rotational alignment accuracy. The findings demonstrate that projection-domain consistency complements conventional reconstruction-based calibration metrics and provides a practical framework for assessing calibration robustness. This approach may improve the reliability of DRR generation and fluoroscopy-guided vertebral registration in image-guided spinal applications.

Explore similar work

Jun 15, 2026cs.CV

Transformation-driven generation of comparable projection images from multimodal anatomical scenes

This work addresses the computational problem of generating reproducible projection-space observations from heterogeneous anatomical scenes whose components may undergo independent spatial transformations. We propose a transformation-driven framework for synthetic projection imaging from multimodal anatomical data and demonstrate it on mandibular-motion scenarios. In contrast to conventional Digitally Reconstructed Radiograph (DRR) approaches primarily designed for registration, projection realism, or rendering efficiency, the proposed formulation treats projection imaging as an observation process operating on an explicitly represented anatomical scene. Independently transformable volumetric and surface-based anatomical objects are embedded within a shared scene representation and propagated directly into projection space through explicit transformations. Projection geometry, acquisition modelling, material interpretation, and image presentation remain explicitly separated, enabling controlled exploration of methodological assumptions while preserving reproducibility and direct comparability between generated projections. Particular emphasis is placed on transformation-driven anatomical scenarios relevant to craniofacial analysis, including mandibular motion and therapeutic repositioning. Using a shared anatomical reference scene composed of CT/CBCT volumes, segmented structures, surface models, and auxiliary anatomical or therapeutic objects, the framework enables generation of directly comparable VirtualRTG projections from multiple anatomical configurations while preserving identical imaging assumptions. Rather than aiming at fully physically faithful radiographic simulation, the proposed approach provides a controllable and reproducible methodological environment for studying anatomy--projection relationships, motion observability, and transformation-aware imaging workflows.
Dariusz Pojda, Krzysztof Domino, Michał Tarnawski +1
Jun 10, 2026cs.CV

Spatially Coupled Phase-to-Depth Calibration for Fringe Projection Profilometry

In fringe projection profilometry (FPP), depth is commonly recovered by fitting a phase-to-depth relation independently at each camera pixel. Although such pixel-wise calibration achieves high local accuracy, neighboring pixels can acquire markedly different calibration functions even when they observe the same smooth surface, producing spatially inconsistent geometry and structured surface artifacts. We propose a spatially coupled phase-depth transformation in which all pixels share a single low-dimensional mapping-global phase scalars combined with affine spatial terms on the undistorted reference-camera grid-rather than independent per-pixel fits, optionally augmented by a bounded, spatially smooth correction field. We further introduce a native-grid pairing scheme that constructs phase-depth calibration pairs directly on the reference-camera grid: when depth supervision comes from a rectified active-stereo pipeline, planes are fitted in stereo 3D and sampled back onto the camera grid along native rays, so the phase maps are never rectified. On a dental target with high-resolution scanner ground truth, the proposed model attains point-to-surface RMSE comparable to an active-stereo reference (about 12μm aggregate) while substantially improving spatial coherence over pixel-wise polynomial and rational calibration, and reduces the runtime mapping to a few element-wise operations per pixel with negligible parameter storage.
Sehoon Tak, Jae-Sang Hyun
Jul 14, 2026eess.IV

Exact and Calibrated Diffusion Reconstruction for Digital Breast Tomosynthesis

Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, 2525^{\circ} protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge. Conditional diffusion priors achieve strong perceptual quality here but leave three clinical obstacles: inexact data consistency, unlocalized hallucination, and uncalibrated uncertainty. We enforce measurements exactly by replacing the per-step proximal update of a conditional diffusion sampler with exact Euclidean projection onto the data-consistent set, computed via an mm-dimensional dual system with a one-time Gram matrix AAAA^{\top} factorization. This projection costs 4.5 ms per step (a 248×248\times speedup) and drives the data residual to the double-precision floor (2.4×10132.4\times10^{-13}). We prove it is the ρ0ρ\to0 limit of the proximal step, provide a no-harm theorem, and show that exactly consistent sample ensembles have variance supported on null(AA). Thus, the mean's entire error lies in the unmeasured subspace covered by the uncertainty map. On patient-derived breast phantoms, this improves fidelity at no depth-resolution cost. Conversely, a proximal step applied post-update degrades quality, isolating the consistency step's placement as decisive. Isotonic recalibration brings the ensemble spread to a calibrated error scale (expected calibration error 0.0290.0080.029\to0.008; standardized error 4.70.964.7\to0.96), ranking errors better than the pure prior. We also repair a 20.3% adjoint mismatch in a deployed projector via a materialized operator of record. This is the first data-consistent, uncertainty-calibrated learned reconstruction for limited-angle DBT. The solver naturally relaxes to discrepancy-ball and maximum-a-posteriori modes for noisy measurements.
Imade Bouftini