cs.CLJul 21, 2026

MIRA-Ev:A Benchmark for Granular Evidence Detection and Relational Reasoning in Clinical Exams

Authors: Iker De la IglesiaJohanna Ramirez-RomeroJose Maria Villa-GonzalezIrune Urroz GarcíaAnder BarrenaAitziber Atutxa

Organizations: HiTZ Center, University of the Basque Country (EHU) · Hospital Universitario de Cruces

Abstract

Clinical NLP evaluation remains dominated by multiple-choice question answering (MCQA), which scores only final-answer accuracy and cannot detect when a model reaches the correct diagnosis while grounding it in irrelevant, absent, or contradictory evidence. We introduce MIRA-Ev, a clinical argument mining benchmark built on Spanish Médico Interno Residente (MIR) licensing-exam cases, re-annotated by expert clinicians with span-level premises, claims, and directed support/attack relations, and released in parallel Spanish (native), English, and Basque versions, the first clinical argumentation resource in Basque. MIRA-Ev organizes evaluation into a three-tier task hierarchy: evidence sentence retrieval, argumentative component extraction, and relation classification.

Explore similar work

May 11, 2026cs.CL

ClinicalBench: Stress-Testing Assertion-Aware Retrieval for Cross-Admission Clinical QA on MIMIC-IV

Reasoning benchmarks measure clinical performance on clean inputs. We evaluate the step before reasoning: retrieval over real EHR notes, where negation, temporality, and family-versus-patient attribution can flip a correct answer to a wrong one. EpiKG carries an assertion label and a temporality tag with every fact in a patient knowledge graph, then routes retrieval by question intent. ClinicalBench is a 400-question test over 43 MIMIC-IV patients across 9 assertion-sensitive categories. A 7-condition ablation tests each piece of EpiKG across six LLMs (Claude Opus 4.6, GPT-OSS 20B, MedGemma 27B, Gemma 4 31B, MedGemma 1.5 4B, Qwen 3.5 35B). Three physicians blindly adjudicated 100 paired items. The author-blind primary endpoint, leave-author-out paired exact McNemar on 50 unanimous-strict items rated by two external physicians, yields +22.0 percentage points (95 percent Newcombe CI [+5.1, +31.5], p=0.0192). The architectural novelty, intent-aware KG-RAG over a Contriever dense-RAG baseline (C2b to C4g_kw on the change-excluded n=362 endpoint), is +8.84 percentage points (paired McNemar p=1.79e-3); +12.43 percentage points under oracle intent. Sensitivities agree directionally: three-rater physician majority +24.0 percentage points (subject to single-author circularity); deterministic keyword reproducibility proxy +39.5 percentage points. Across the six models, the gain shrinks as the LLM-alone baseline rises (beta=-1.123, r=-0.921, p=0.009). With n=6 this looks more like regression to the mean than encoding substituting for model size. Physician adjudication identified 56 percent of auto-generated reference answers as defective, a methodological finding indicating that NLP-pipeline clinical-QA benchmarks require physician adjudication to be usable. ClinicalBench, the frozen evaluator, three-rater adjudication data, and the EpiKG output stack are publicly released.
Alex Stinard
Aug 7, 2026cs.AI

CliniCARE-Bench: Clinical Calibrated Audit of Medical Reasoning in EHR

Large language models perform strongly on medical knowledge benchmarks, but reliable clinical deployment requires agents to conduct defensible investigations over heterogeneous, longitudinal records: determining what evidence is needed, retrieving and reconciling structured and free-text data, grounding conclusions in verifiable evidence, and deferring cases that cannot be resolved reliably. We introduce CliniCARE-Bench (Clinical Calibrated Audit of Medical Reasoning in EHR), a benchmark for retrospective clinical audit: 25 clinician-validated scenarios instantiated as 750 patient-specific cases over real-patient-derived MIMIC-IV data. Systems investigate each case through a governed, logged tool environment for record retrieval, computation, and policy access, and return one of four verdicts---Yes, No, Indeterminate: Lack of Data, or Indeterminate: Medically Ambiguous---the last two separating missing evidence from residual medical ambiguity. Beyond verdict accuracy, we score patient-evidence and policy grounding, process adherence, calibrated abstention, reliability, and efficiency against case-level reference verdicts produced by independent multi-model adjudication and calibrated against Clinical Board review. Every retrieval, computation, and report is replayable, so the investigation trace is inspectable and scorable. To our knowledge, CliniCARE-Bench is the first deployment-oriented clinical-agent benchmark to jointly evaluate real longitudinal EHR investigation, claim-level evidence grounding, governing-policy use, process adherence, and calibrated abstention within a common patient-level adjudication framework. Across 16 agentic systems, four-way accuracy spans 65.3-76.1%, but raw accuracy overstates investigation quality. Defect-free accuracy, which credits a verdict only when correct and free of prohibited shortcuts, is 4.8-14.8 points lower and reorders the leaderboard.
Veronica Chatrath, Bryan Zhu, George Pu +16
May 20, 2026cs.CL

When Cases Get Rare: A Retrieval Benchmark for Off-Guideline Clinical Question Answering

Across medical specialties, clinical practice is anchored in evidence-based guidelines that codify best studied diagnostic and treatment pathways. These pathways routinely fall short for the long tail of real-world care not covered by guidelines. Most medical large language models (LLMs), however, are trained to encode common, guideline-focused medical knowledge in their parameters. Current evaluations test models primarily on recalling and reasoning with this memorized content, often in multiple-choice settings. Given the fundamental importance of evidence-based reasoning in medicine, it is neither feasible nor reliable to depend on memorization in practice. To address this gap, we introduce OGCaReBench, a free-form retrieval-focused benchmark aimed at evaluating LLMs at answering clinical questions that require going beyond typical guidelines. Extracted from published medical case reports and validated by medical experts, OGCaReBench contains long-form clinical questions requiring free-text answers, providing a systematic framework for assessing open-ended medical reasoning in rare, case-based scenarios. Our experiments reveal that even the best-performing baseline (GPT-5.2) correctly answers only 56% of our benchmark with specialized models only reaching 42%. Augmenting models with retrieved medical articles improves this performance to up to 82% (using GPT-5.2) highlighting the importance of evidence-grounding for real-world medical reasoning tasks. This work thus establishes a foundation for benchmarking and advancing both general-purpose and medical LLMs to produce reliable answers in challenging clinical contexts.
Doeun Lee, Muge Zhang, Yi Yu +11