cs.CVJul 29, 2026

PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation

Authors: Yehui YangBo ZhaoJunzhe CaoHui MaYue SunWenjin WangZitong Yu

Organizations: 1Great Bay University · 2Shenzhen University of Advanced Technology · 3Macao Polytechnic University · 4Southern University of Science and Technology

Abstract

Remote photoplethysmography (rPPG) enables non-contact heart-rate estimation from facial videos, but its weak physiological signal is easily corrupted by motion, illumination changes, occlusion, skin-appearance variation, and device noise. Existing rPPG methods typically rely on a single model to directly predict heart rate or recover pulse waveforms, while different strong estimators may produce conflicting yet individually plausible candidates for the same video. To resolve these conflicts, we propose PhysAgent, an inference-time multi-agent candidate-verification framework. Unlike direct prediction approaches, PhysAgent neither trains a new base rPPG model nor asks Multimodal Large Language Models (MLLMs) to output heart rate directly. In contrast, it treats outputs from multiple base estimators as physiological hypotheses to be verified and uses a lightweight 4B MLLM, Qwen3-VL-4B, to drive multi-agent reasoning over video conditions, signal reliability, and candidate disagreement. A deterministic physiological verifier checks the fusion proposal, and a reproducible numerical fusion process produces the final heart rate. Experimental results on multiple public rPPG benchmarks show that PhysAgent improves fusion stability and reliability across different datasets and source-domain settings, while avoiding the irreproducibility and physiological inconsistency of direct MLLM prediction or unconstrained ensemble fusion. The code will be released soon.

Explore similar work

Jun 10, 2026cs.CV

Illumination-Robust Camera-Based Heart-Rate Estimation for Physiological Sensing in Robots

Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight (β\mathbfβ) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that β=5\mathbfβ=5 provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Zhi Wei Xu, Torbjörn E. M. Nordling
Aug 30, 2026cs.CV

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.
Zixu Li, Jianjun Qian, Hang Shao +3
Jul 17, 2026cs.CV

CanonicalPhys: Pose-Robust Remote Photoplethysmography via Canonical-Space Priors

Deep remote photoplethysmography (rPPG) attains sub-bpm heart-rate error on frontal, stationary faces yet degrades sharply under head pose: on MMPD, the state-of-the-art FactorizePhys backbone's MAE grows 1.60×1.60\times from frontal (yaw<15|\text{yaw}|{<}15^\circ) to large-yaw (yaw45|\text{yaw}|{\geq}45^\circ) frames. We argue that pose is a \emph{coordinate-structural} nuisance rather than a data-augmentation problem: in image coordinates the same pixel maps to different anatomy at different poses, blocking three priors otherwise natural for rPPG, namely the dichromatic reflection model, pulse-phase invariance across skin regions, and the POS/CHROM chromaticity projection, each of which presumes a stable anatomy-to-pixel mapping. We introduce \textbf{CanonicalPhys}, which prepends a differentiable four-point homography that fixes four facial anchors at canonical positions; in this canonical frame the three priors become expressible as a per-pixel Lambertian weight, a cross-ROI temporal consistency loss, and knowledge distillation from windowed POS, none of which adds trainable parameters over the backbone. At an identical parameter count, CanonicalPhys reduces MMPD's frontal-to-large-yaw MAE degradation from 1.60×1.60\times to 1.33×1.33\times and flattens the mild-yaw bin from 1.32×1.32\times to 1.07×1.07\times (across CanonicalPhys variants), with matched cross-dataset MAE reductions of up to 32%32\% on pose-rich targets. Code: https://github.com/infraface/CanonicalPhys
Hui Wei, Seyedata Jodeiri Seyedian, Xiaobai Li +1