cs.CVAug 4, 2026

When Oracle Conditioning Misleads Deployment: Conditioning-Availability Bias in Echocardiographic Segmentation

Authors: Dang P. M. CaoHieu D. PhamHieu Pham

Organizations: College of Engineering and Computer Science, VinUniversity, Hanoi, Vietnam · VinUni-Illinois Smart Health Center, VinUniversity, Hanoi, Vietnam · Center for Innovations in Health Sciences, VinUniversity, Hanoi, Vietnam

Abstract

Conditional segmentation models may be trained and evaluated with auxiliary signals cleaner than those available at deployment. We study this protocol-level manifestation of shortcut learning and auxiliary-variable shift in phase-conditioned echocardiographic segmentation. The complementary gap pair measures loss on the deployable oracle-estimated pathway and probes sensitivity on the oracle-random pathway. On held-out CAMUS data, one strong-cyclic, oracle-selected run fails severely with estimated phase, while sensitivity to incorrect phase persists across three runs. On EchoNet-Dynamic, the current estimator remains usable, but random-phase testing reveals strong latent sensitivity. Deployment-aware checkpoint selection and phase perturbation reduce both gaps with little change in mean Dice. Exploratory subgroup analyses quantify variation across measured strata, and a downstream ejection fraction (EF) audit shows that recovering segmentation does not necessarily recover EF error or signed bias. Together, the gaps test whether oracle-conditioned performance survives the inference pathway actually available at deployment.

Explore similar work

Aug 11, 2026cs.CV

VIDS-Seg: Towards Reliable Uncertainty Quantification in Pediatric Cardiac Ultrasound Segmentation

Reliable clinical deployment of machine learning requires models that know when they are likely to fail, particularly for subgroups underrepresented in training data. A common case is pediatric care, where models trained on adult cohorts can silently under-perform on children with no indication that something has gone wrong. As retraining with labeled pediatric data is often infeasible, detecting such failures at inference time is a critical clinical need. Building on the VIDS (Variational Inference under Distribution Shifts) framework, we introduce VIDS-Seg, which applies amortized variational inference over a lightweight prediction head to make this adaptive, OOD-aware prior tractable for dense image segmentation. We evaluate VIDS-Seg on left ventricular segmentation in echocardiography, a setting where pediatric anatomy differs systematically from the adult population most segmentation models are trained on, training on an adult cohort (EchoNet-Dynamic) and evaluating zero-shot on a pediatric cohort (EchoNet-Pediatric). Across all age strata, VIDS-Seg matches competitive baselines in segmentation accuracy while producing substantially higher spatial correspondence between predicted uncertainty and segmentation error, an advantage that persists even after applying temperature scaling to all baselines. Downstream, it yields more accurate and stable ejection fraction estimates and more reliable detection of cardiac malfunction in the infant subgroup. Our results indicate that OOD-aware uncertainty quantification can serve as a practical safety layer for deployed segmentation models, enabling detection of silent failures in underrepresented subgroups without retraining or additional labeled data.
Paul Fischer, Ece Ozkan
Date pendingcs.CV

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/
John Bonnici, Matthew Baugh, Aleksandra Kulbaka +3
Jul 22, 2026cs.CV

Domain Shift in Echocardiography: Interpretable Quantification and Prediction of Cross-Dataset Left Ventricular Segmentation

Cross-dataset generalisation remains a major barrier to clinical deployment of echocardiographic left ventricular segmentation, yet the sources of this shift are rarely disentangled. We examined whether transfer degradation could be estimated before deployment using handcrafted ultrasound descriptors, VAE latent features, and segmentation-derived latent features across six echocardiographic datasets. Geometry-aware preprocessing substantially improved several poor transfer cases, suggesting that much of the apparent domain shift reflects field-of-view and framing inconsistencies rather than intrinsic acoustic differences alone. Intensity z-normalisation changed dataset separability by less than 0.005, indicating that brightness and contrast are not the dominant shift axis. Absolute Dice drop on held-out source-target pairs was predicted with an R-squared value of 0.612, an MAE of 0.082, and a Spearman rho of 0.681. The variant without LV and fan-shaped features retained approximately 70% of this explanatory power, supporting mask-free transfer-risk monitoring. The most informative discrepancy measure depended on the representation, with CMD strongest in z-normalised handcrafted features, with an absolute r of approximately 0.86 and an R-squared value of approximately 0.70; log-Wasserstein strongest in VAE space, with an r of approximately -0.90 and an R-squared value of approximately 0.81; and log-MMD strongest in LV-segmentation latent features, with an r of approximately -0.92 and an R-squared value of approximately 0.84. Apparent vendor effects were largely dataset-confounded. Echocardiographic domain shift is therefore structured and measurable, and its impact on segmentation can be partly reduced through geometry-aware preprocessing and anticipated using representation-specific transfer-risk estimation.
Soroush Elyasi, Nasim Dadashi Serej, Julie Wall +1