Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment. Whether agreement with an institution's reference standard transfers across sites, findings, prediction directions and question formats is largely unmeasured. We evaluated three generative vision-language models on three institutional chest-radiograph corpora and six findings under two elicitation protocols, comprising more than 345,000 finding-level predictions, and estimated finding-by-direction reference agreement at a receiving institution from a small budget of local labels. Estimation strategies were then stress-tested under repeated strict institution-held-out evaluation. Under evaluation excluding the receiving institution from development entirely, adaptive selection among the seven estimators that design admits did not improve on simple fixed alternatives: it achieved a mean Brier score of 0.1083, against 0.0853 for always using a Beta-Binomial empirical-Bayes estimator and 0.0855 for a target-only logistic model. Those two differ by 0.0003, less than this family's own sensitivity to a change of solver version, and each leads in about half the settings, so no default can be recommended. Their advantage over estimators pooling across institutions was concentrated at one site and not confirmatory once clustered by institution, and a plug-in empirical-Bayes posterior-predictive count interval at a nominal 95% level covered 87.0%, less at the hardest institution. Reference agreement therefore has to be re-evaluated per site and per interface; these results concern agreement with institutional labels, not clinical correctness.
Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image. That inference is unsafe: a model exploiting finding-name priors scores like one that reads the scan, and no standard benchmark separates them. We introduce a causal audit that intervenes on the image, occluding the relevant region, occluding an irrelevant one, and swapping in another patient's same-label scan, and combines three behavioral metrics to test whether a correct answer depends on the image. Across nine systems, a text-only model with no image access reaches within 5.7 accuracy points of the best multimodal one, and a 119-billion-parameter multimodal model is statistically indistinguishable from a 7-billion text-only baseline. The audit splits the cohort into three models that ignore the image, one that is unstable, and five that use it selectively, for a subset of findings; the categories hold across a second dataset, resolution, and prompt phrasing. Against board-certified radiologists, a text-only model is statistically indistinguishable from a radiologist's accuracy while grounding at zero, whereas the image-using models ground at radiologist-comparable rates. Reported confidence flags ungrounded answers only when a model uses the image. Grounding audits, not accuracy, should gate clinical deployment.
Mahshad Lotfinia, Sebastian Ziegelmayer, Lisa Adams +3
A vision-language model can answer a question about a medical image fluently and confidently while barely using the image, leaning instead on language priors. In medicine this is the failure that matters most, because the answer looks trustworthy and is not, and the only protection is a confidence score reliable enough to tell the system when to abstain. We ask a deployment question rather than an accuracy one: how much imaging work a model can safely handle alone, and which confidence signal makes that possible. We evaluate seven confidence estimators across five open-weight LVLMs and three medical visual-question-answering datasets spanning broad clinical imaging, radiology, and pathology, with every probe trained only on natural images and applied without adaptation. Recast as bounded selective prediction (automate a case only when confidence clears a threshold, defer the rest), the comparison is cautionary. The standard metrics are poor guides: discrimination barely separates the methods, and the weak calibration of a cheap self-report is cheaply removed by off-domain temperature scaling without changing deployable yield. What distinguishes a usable estimator is the high-confidence region a clinician acts on: the weakest baselines are confidently wrong on 41 to 45 percent of their errors against 1 to 4 percent for the best probe, and no estimator is reliably best across domains or models. Safe handoff is governed at two levels: base-model competence sets a ceiling, so a well-calibrated score recovers roughly a third of radiology cases at a 20 percent error tolerance but almost none of pathology; the confidence layer then decides how much of that ceiling is reachable. The usable role today is calibrated triage, not autonomy: automate the cases a calibrated score marks safe, route the rest to a clinician. We release all outputs, correctness judgments, and confidence scores, with code.
Reza Khanmohammadi, Kundan Thind, Mohammad M. Ghassemi
Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment. However, commonly used report-derived labels for pathology classification or generic image quality metrics for reconstruction may not reliably reflect clinical judgment. We systematically investigate how evaluation-reference choices affect model performance and ranking in both pathology classification and image quality assessment (IQA). To enable controlled comparison across evaluation references, we collected paired expert image- and report-derived labels for thoracic findings from a clinical cohort at Cambridge University Hospitals (CUH) and curated a subset of the public MIMIC-CXR dataset, along with expert ratings of diagnostic image quality. We show that for supervised image classifiers (ResNet, DenseNet), several zero-shot and fine-tuned vision-language models (e.g., MedKLIP, GLoRIA, and ConVIRT), changing the label source leads to substantial differences not only in performance estimates but also in model rankings. In parallel, alignment of IQA measures with expert judgment depends heavily on the choice of measure, and commonly used IQA metrics such as SSIM and PSNR often fail to align with expert assessments of diagnostic usability. Our results demonstrate that evaluation choices are crucial: they can determine which models and methods appear best and are therefore selected for further development or deployment. The selection of evaluation references should therefore be treated as a central component of clinical validity in CXR machine learning, and justified with respect to the pathology, imaging task, and intended downstream clinical use.