Organizations: The Hong Kong University of Science and Technology (Guangzhou)
Abstract
Text-conditioned chest X-ray generation aims to synthesize realistic radiographs that faithfully depict specified findings. Existing work has primarily improved quality by updating image generators, implicitly treating prompts as fixed after CXR-domain adaptation. We show that this generator-centric view leaves a substantial optimization dimension underexplored. With a CXR-adapted Sana generator frozen, one-pass reformulation by an unmodified LLM reduces RadDINO-FID from 54.225 to 27.572. Prompt analysis shows that the LLM suppresses temporal comparisons, uncertainty, and other non-renderable report content while emphasizing visible radiographic findings. However, unconstrained reformulation reduces BioViL-T alignment with source prompts from 0.695 to 0.609. We therefore introduce JustLLMGRPO, which applies standard Group Relative Policy Optimization (GRPO) only to the LLM prompt policy while keeping Sana frozen. Group-relative radiology-aware image feedback retains visual focus while preserving source-prompt alignment. On CheXGenBench, JustLLMGRPO reduces RadDINO-FID to 26.780, a 50.6% improvement over direct prompting, while maintaining alignment (0.696 versus 0.695). It also achieves state-of-the-art distribution coverage and downstream classification utility. These results show that substantial performance can remain latent in how radiographic information is expressed to an adapted generator. Code is publicly available at https://github.com/pxcai/JustLLMGRPO.
Medical imaging is a cornerstone of diagnostics, yet automated chest X-ray report generation struggles with structural adherence, anatomical completeness, and semantic faithfulness. We introduce DobicVLM, a vision-language model combining supervised fine-tuning on MedGemma-4B with Group Relative Policy Optimization (GRPO) and clinically-grounded programmatic rewards. Our approach uses interpretable, rule-based reward components; structural verification, anatomical checklist, semantic similarity, and length constraints to enforce clinical standards without neural reward models. Trained on 1,000 de-identified image-report pairs from a private clinical dataset (with ethics approval and compliance to local regulations), DobicVLM is evaluated via blinded expert review on 69 held-out cases. DobicVLM outperforms Gemini 2.5 Flash across the majority of criteria, achieving the highest impression accuracy (27.2%) and medical terminology (86.5%) compared to both Gemini 2.5 Flash and MedGemma 4B baselines, with minor trade-offs in completeness and referrals. This demonstrates GRPO's value for transparent alignment in resource-limited settings. Keywords: Vision-Language Models, Radiology Report Generation, Reinforcement Learning, Medical AI, GRPO
We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale. Existing radiographic AI models often suffer from poor generalisation across patient subpopulations, institutions, and acquisition settings, resulting in limited real-world clinical utility. Controlled, high-fidelity synthesis of chest radiographs is a promising path toward diversifying clinical datasets and evaluating the robustness of diagnostic models. Therefore, we present the largest specialist generative foundation model for chest radiographs to date, with over 1.3B parameters, trained for 1.6T tokens on a curated, heterogeneous dataset comprising 1.2M radiographs and clinical expert-guided metadata. Our model supports controllable radiograph generation and editing across multiple demographic subgroups, acquisition views, and a dozen pathologies. Moreover, we significantly advance the state of the art in radiograph synthesis fidelity, producing images that are indistinguishable from real radiographs to clinical experts.
Fabio De Sousa Ribeiro, Emma A. M. Stanley, Charles Jones +7
A clinically useful chest X-ray system must go beyond fluent report generation: it should classify findings with tunable decision thresholds, localize them spatially, and derive the anatomical measurements upon which many diagnoses depend. Today's Vision-Language Models (VLMs) treat these as separate problems, if they address them at all, leaving a gap between what radiologists need and what generative models provide. We introduce CARE-X, a chest X-ray VLM that narrows this gap by unifying auxiliary discriminative supervision with reward-aligned generation. CARE-X augments its generative backbone with focal-loss classification and composite-loss grounding heads, co-trained alongside the language-modeling objective. This auxiliary supervision produces discriminative diagnostic predictions with tunable decision thresholds and precise spatial localization while also improving report quality, providing evidence that structured prediction and generation reinforce one another. Building on this foundation, Decoupled Clip and Dynamic Sampling Policy Optimization (DAPO) leverages task-specific reward signals for report generation, visual question answering (VQA), and spatial grounding, directly optimizing the clinical quality metrics that matter in practice. The result is state-of-the-art performance on the majority of metrics across four report-generation benchmarks, 94.0% VQA accuracy on ReXVQA (+6.0 pp over the next-best baseline), and generative spatial decoding that reaches near parity with dedicated detection heads. Separately, to address measurement-dependent diagnoses, we couple Qwen3-VL-4B-Instruct with native tool-calling capabilities for invoking deterministic measurement tools, while retaining full visual access to the image. This hybrid inference yields +43.6 pp average F1 over perception-only baselines across five measurement-dependent conditions.
Mercy Prasanna Ranjit, Anirban Porya, Sathvik Joel +8