eess.IVAug 14, 2026

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

Authors: Yuanchao Bai, Yifan Zhao, Kai Wang, Yuanbo Du, Jie Cheng, Teng Fang, Xianming Liu, Wen Gao

Organizations: Faculty of Computing, Harbin Institute of Technology, Harbin, 150001, China · Huawei Tech. Company, Ltd. · School of Electronics Engineering and Computer Science, Peking University, Beijing, 100871, China, and Pengcheng Laboratory, Shenzhen, 518055, China

Abstract

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

Figures & tables

Explore similar work

Mar 12, 2026

MedPruner: Training-Free Hierarchical Token Pruning for Efficient 3D Medical Image Understanding in Vision-Language Models

While specialized Medical Vision-Language Models (VLMs) have achieved remarkable success in interpreting 2D and 3D medical modalities, their deployment for 3D volumetric data remains constrained by significant computational inefficiencies. Current architectures typically suffer from massive anatomical redundancy due to the direct concatenation of consecutive 2D slices and lack the flexibility to handle heterogeneous information densities across different slices using fixed pruning ratios. To address these challenges, we propose MedPruner, a training-free and model-agnostic hierarchical token pruning framework specifically designed for efficient 3D medical image understanding. MedPruner introduces a two-stage mechanism: an Inter-slice Anchor-based Filtering module to eliminate slice-level temporal redundancy, followed by a Dynamic Information Nucleus Selection strategy that achieves adaptive token-level compression by quantifying cumulative attention weights. Extensive experiments on three 3D medical benchmarks and across three diverse medical VLMs reveal massive token redundancy in existing architectures. Notably, MedPruner enables models such as MedGemma-1.5 to maintain or even exceed their original performance while retaining fewer than 5% of visual tokens, thereby reducing visual-token overhead and validating the necessity of dynamic token selection for practical clinical deployment. Our code is available at https://github.com/CUHK-AIM-Group/MedPruner.
May 1, 2026

Learning from Compressed CT: Feature Attention Style Transfer and Structured Factorized Projections for Resource-Efficient Medical Image Analysis

The deployment of artificial intelligence in medical imaging is hindered by high computational complexity and resource-intensive processing of volumetric data. Although chest computed tomography (CT) volumes offer richer diagnostic information than projection radiography, their use in AI-based diagnosis remains limited due to the computational burden of processing uncompressed volumetric images (typically stored in NIfTI or DICOM format). Addressing the growing need for low-resource deployment and efficient electronic data transfer, we investigate the utilization of JPEG-compressed chest CT volumes for thoracic abnormality detection. We propose Feature Attention Style Transfer (FAST), a novel distillation framework that transfers both activation patterns and structural relationships from high-fidelity CT representations to a spatiotemporal visual encoder operating on compressed inputs. By combining Gram-matrix-based attention style preservation with dual-attention feature alignment, FAST enables robust feature extraction from degraded volumes. Furthermore, we introduce Structured Factorized Projection (SFP), leveraging Block Tensor Train decomposition as a parameter-efficient alternative to dense projection layers, reducing projection-head parameters by almost half. Our contrastive learning pipeline, CT-Lite, integrates these components with a SigLIP-based multimodal alignment objective. Experiments on CT-RATE, NIDCH, and Rad-ChestCT demonstrate that CT-Lite achieves AUROC within 5-7% of the uncompressed-input baseline across all three datasets, despite operating on compressed inputs with significantly fewer parameters, paving the way for AI-based clinical evaluation under resource constraints.
Jul 29, 2026

MedARC: Training-Free Adaptive Redundancy Compression of Visual Tokens for 3D Medical Vision-Language Models

Integrating 3D medical images with vision-language models (VLMs) holds substantial promise for computer-aided diagnosis. However, volumetric images generate prohibitively long visual-token sequences with considerable spatial and inter-slice redundancy. Existing token compression methods typically apply uniform reduction or rely on a single importance signal, increasing the risk of removing regions that are clinically relevant to the query or structurally distinctive. To address this limitation, we propose MedARC, a unified, training-free framework for Adaptive Redundancy Compression of visual tokens in 3D medical VLMs. MedARC estimates token importance by integrating three complementary cues: self-attention from the VLM vision encoder, which reflects the model's intrinsic visual focus; similarity between projected visual tokens and text embeddings, which identifies query-relevant regions; and deviations of local visual foundation model features from the volume-level feature center, which highlight structurally distinctive anatomy. The resulting importance distribution guides a saliency-aware merging strategy that preserves informative tokens while consolidating redundant ones rather than simply discarding them. Experiments on CT-RATE and MR-RATE show that MedARC reduces visual-token overhead and inference time while preserving or improving diagnostic performance. Its multi-cue scoring cost is outweighed by the savings from processing fewer tokens, with greater benefits expected for larger language models.