Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening
Authors: Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant, Davood Karimi
Organizations: Department of Radiology, Boston Children’s Hospital, and Harvard Medical School, Boston, USA · Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, China · Centre for Artificial Intelligence and Robotics, Hong Kong Institute of Science & Innovation, Chinese Academy of Sciences, Hong Kong, China · Shenzhen Luohu People’s Hospital, Shenzhen, China · School of Artificial Intelligence, Shenzhen University, Shenzhen, China · School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, China
Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement. Fetal brain MRI provides more reliable volumetric information but is costly and less accessible for routine use. To address these limitations, we propose VIFBA, an ultrasound video-based framework for fetal brain assessment that predicts MRI-derived lateral ventricular volume, classifies VM severity, and identifies potential non-VM fetal brain abnormalities. Our contribution is three-fold. First, we introduce a joint-embedding predictive architecture (JEPA)-inspired tube latent prediction objective that leverages spatio-temporal coherence in ultrasound videos to enhance representation learning. Second, we develop a contrastive cross-modal alignment strategy that transfers structural information from MRI to ultrasound during training, while requiring ultrasound alone at inference. Third, we augment VIFBA with a training-free vision-language model and retrieval augmentation to verify uncertain predictions and identify potential non-VM fetal brain abnormalities. We validated VIFBA on a large dataset comprising 857 cases (3,196 videos) with paired fetal brain ultrasound and MRI examinations. On held-out test data, VIFBA achieved an MAE of 0.5909 mL and Pearson correlation coefficient of 0.9907 for ventricular volume regression, 0.9400 accuracy for VM severity classification, and an F1 score of 0.7764 for multi-abnormality classification, substantially outperforming single-task baselines, video-based strong competitors, and state-of-the-art foundation models. By enabling MRI-informed volumetric assessment from routine ultrasound alone, VIFBA offers a practical and potentially broadly deployable pathway toward accurate and affordable prenatal brain screening.
Figures & tables
Fig. 1: Overview of the training pipeline of our proposed method.
Fig. 2: Testing pipeline of our proposed method, including case-level testing, and VLM verification and non-VM brain abnormality alerting.
Fig. 3: Volume calculation overview in our data preprocessing stage.
Fig. 4: Details of our dataset. (a) bilateral ventricle volume between fetal subjects in the Developing Human Connection Project [ 69 ] (segmentation results generated using DrawEM [ 70 , 71 ] and quality-controlled by the dHCP team) and ours (segmented by deep models [ 31 , 33 ] ). Together, the scatter plot analysis and expert visual inspection provide further validation of the accuracy of the automatic segmentation method. (b) Statistical distribution of bilateral ventricle volume in non-VM and mild, moderate, and severe VMs across different gestational age groups (weeks). (c) Distribution of case counts across six abnormality categories (A1–A6, details refer to Section IV-A ) among different groups, including non-VM abnormal brain and mild, moderate, and severe VMs. (d) The UpSet plot illustrates the set size of each category (VM and A1–A6) and the quantitative distribution of their complex intersections.
Level
Group
MSE ↓
RMSE ↓
MAE ↓
Pearson ↑
Spearman ↑
Video
G1
0.2531
0.5031
0.4390
0.9535
0.9295
G2
0.7298
0.8543
0.7338
0.9618
0.8809
G3
2.5167
1.5864
1.4416
0.9208
0.8684
G4
7.0826
2.6613
2.2956
0.9611
1.0000
G5
7.6917
2.7734
2.5630
0.9479
1.0000
Overall
1.6476
1.2836
0.9364
0.9793
0.9403
TABLE I: Regression performance across different groups using video-level output aggregation and case-level feature aggregation. Red subscripts denote the absolute performance gains of case-level feature aggregation over video-level output aggregation. G1: Healthy brain, G2: Non-VM abnormal brain, G3: Mild VM, G4: Moderate VM, and G5: Severe VM.
MSE
RMSE
MAE
Pearson
Spearman
I3D
12.6789
3.5607
2.7929
0.8470
0.6547
R(2+1)D
13.0733
3.6157
2.5684
0.8243
0.6678
TimeSformer
11.8981
3.4494
2.6758
0.8906
0.7331
InternVideo2
11.4605
3.3853
2.5386
0.9510
0.8318
VideoMamba
12.0456
3.4707
2.6615
0.8752
0.7496
V-JEPA2
10.8888
3.2998
2.6546
0.8821
0.6937
TABLE II: Method Comparison on the regression task.
Acc
Pre
Rec
F1
AUC
I3D
0.7000
0.6361
0.7611
0.6610
0.8899
R(2+1)D
0.7000
0.6264
0.7086
0.6450
0.8659
TimeSformer
0.7300
0.6462
0.7196
0.6666
0.9006
InternVideo2
0.7500
0.6605
0.7545
0.6762
0.9030
VideoMamba
0.7300
0.6498
0.7424
0.6670
0.8996
V-JEPA2
0.7700
0.7247
0.7604
0.7208
0.9199
TABLE III: Method Comparison on the classification task.
Fig. 5: Comparisons with statistical significance analysis between VIFBA and competitors on (a) regression and (b) classification tasks. Each cell reports the p -value and the mean gain Δ of VIFBA.
Fig. 6: Group-wise detailed regression performance, including normal brain (n=45), non-VM abnormal brain (n=24), mild VM (n=19), moderate VM (n=7), and severe VM (n=5). Y-axis represents lateral ventricular volume (mL). For each group, cases are sorted by the ground-truth lateral ventricular volume ( green circles ). The blue circles indicate the video-level predictions, while the red circles show the case-level output.
Method & Module
Regression
Classification
MSE
RMSE
MAE
Pearson
Spearman
Acc
Pre
Rec
F1
AUC
Baseline (Reg)
9.9199
3.1496
2.6122
0.9033
0.7648
/
/
/
/
/
Baseline (Cls)
/
/
/
/
/
0.7900
0.7387
0.8256
0.7568
0.9186
Baseline (Reg+Cls)
6.3064
2.5112
2.0827
0.9707
0.9304
0.8200
0.7310
0.8423
0.7569
0.9495
TLP
CMTA
VLM
MSE
RMSE
MAE
Pearson
Spearman
Acc
Pre
Rec
F1
AUC
✓
✗
✗
2.1778
1.4757
1.0739
0.9882
0.9179
0.8800
0.8002
0.8890
0.8302
0.9601
TABLE IV: Ablation study on our VIFBA framework.
VIFBA
Regression
Classification
MSE
RMSE
MAE
Pearson
Spearman
Acc
Pre
Rec
F1
AUC
PMC-CLIP
1.1804
1.0864
0.8970
0.9893
0.9239
0.8900
0.8398
0.8917
0.8537
0.9296
BiomedCLIP
1.0475
1.0234
0.8300
0.9915
0.9466
0.9100
0.8652
0.9122
0.8849
0.9572
USFM
0.8702
0.9329
0.7904
0.9965
0.9704
0.9400
0.8878
0.9300
0.9053
0.9717
EchoCare
0.9217
0.9600
0.8049
0.9905
0.9400
0.9300
0.8793
0.8523
0.8580
0.9399
Ultrasound-CLIP
0.9013
0.9494
0.7994
0.9942
0.9376
0.9300
0.8747
0.9550
0.9048
0.9717
TABLE V: Comparison of VIFBA with different foundation model-based encoders.
Fig. 7: Pairwise statistical results among ablation variants on (a) regression and (b) classification metrics. Each cell reports the p -value for testing whether the row method significantly outperforms the column method. Boxes with black borders indicate statistically significant improvements ( p<0.05 ). M1: Baseline (Reg)/(Cls), M2: Baseline (Reg+Cls), M3: TLP, M4: CMTA, M5: VLM, M6: TLP+CMTA, M7: TLP+VLM, M8: CMTA+VLM, M9: VIFBA.
Fig. 8: Performance variation with different numbers of selected videos per case. Full denotes using all available videos for case-level feature aggregation.
Method
Pre
Rec
F1
HL
EMR
VIFBA-CLS-S1
0.4243
0.6299
0.4575
0.1250
0.3200
VIFBA-CLS-S2
0.4762
0.7036
0.5084
0.1110
0.4100
VIFBA
Claude-Haiku-4.5
0.6129
0.7836
0.6673
0.0630
0.6900
Gemini-3.1-Pro
0.6517
0.8027
0.7053
0.0530
0.7000
Qwen3.5-Plus
0.6485
0.7847
0.6861
0.0590
0.7100
GPT-5.4
0.6333
0.8346
0.6941
0.0610
0.7100
TABLE VI: Comparison of VIFBA with baselines and different VLMs on the multi-label classification task. S1: one-stage classification over 10 categories (normal brain, mild/moderate/severe VM, and A1–A6); S2: two-stage classification that first identifies abnormal brains and then determines their specific diseases.
Fig. 9: Multi-seed performance comparison of VIFBA with different foundation encoders. E1–E6 represent PMC-CLIP, BiomedCLIP, USFM, EchoCare, Ultrasound-CLIP, and FetalCLIP, respectively. Statistical significance is denoted as * ( p<0.05 ), ** ( p<0.01 ), *** ( p<0.001 ), and ns (not significant).
Fig. 10: Visualization of selected test cases. For each case, the figure shows example frames from the input ultrasound videos, an axial slice from the reconstructed MRI volume, and ventricular segmentation results obtained from the MRI based on BOUNTI and FeTA segmentors. Note that, to facilitate visualization of the ventricular shape, we have arbitrarily rotated the ventricular segmentation masks for each case. In addition, we show the ground-truth (GT, based on the segmentations/reports and checked by an expert) and VIFBA-predicted (pred) ventricular volumes and diagnostic labels.
Fig. 11: Two typical examples showing the VM verification and multi-abnormality alerting process.
Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia · University Medical Centre Ljubljana, Ljubljana, Slovenia · Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia