cs.CLAug 18, 2026

Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation

Authors: Iryna Hartsock, Cesar Lam, Christopher Otteni, Aliya Qayyum, Robert Gatenby, Cyrillo Araujo, Ghulam Rasool

Organizations: Department of Machine Learning, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, USA · Department of Diagnostic Imaging and Interventional Radiology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, USA · Department of Neuro-Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, USA · Department of Translational Pathology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, USA

Abstract

Purpose: To develop and evaluate a locally deployed multi-agent AI system for radiology report structuring and quality assurance. Materials and Methods: This retrospective study included 638 radiology reports from CT examinations of the chest, abdomen, and pelvis dictated by 15 board-certified radiologists in 2023 and 2024. A multi-agent AI pipeline was developed to perform report structuring and quality assurance (QA). The system structured the report into standardized anatomical sections at the sentence level using regex rules and local large language models. It also detected mismatches between the Findings and Impression sections, or within sections; gender-anatomy conflicts; and undocumented communication of critical findings. Two board-certified radiologists independently evaluated a 45-report subset. Results: The multi-agent system structured the Findings sections of all reports (22,270 sentences) into a predefined anatomical format while retaining the original report content. The system flagged 90 (14.1%) reports, most commonly for section mismatches (80 reports, 12.5%). In the radiologist evaluation, both reviewers agreed that 31 (69%) were correctly restructured, 2 reports (4%) were incorrectly restructured, and disagreed on the remaining 12 reports (27%). Both reviewers agreed that no clinically important information was omitted and no fabricated content was introduced. Overall QA performance was rated as "excellent" or "good" in 84% of the evaluated reports, with the remaining reports rated as "fair". Conclusion: A locally deployed multi-agent AI system combined radiology report structuring and quality assurance within a single workflow. The system demonstrated favorable performance in radiologist evaluation. Such systems may support standardization of reporting and quality assurance in radiology practice.

Figures & tables

Explore similar work

Oct 15, 2026

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.
Jun 13, 2026

ReportQA: QA-Based Radiology Report Evaluation

Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.
Feb 17, 2026

Multi-Modal Multi-Agent Reinforcement Learning for Radiology Report Generation

We propose MARL-Rad, a multi-modal multi-agent reinforcement learning framework for radiology report generation that trains the entire agentic system on policy within its deployed radiology workflow. MARL-Rad addresses the limitation of post-hoc agentization, where fixed LLMs are organized into hand-designed agentic workflows without being optimized for their assigned roles. Our framework decomposes chest X-ray interpretation into region-specific agents and a global integrating agent, and jointly optimizes them using clinically verifiable rewards. Experiments on the MIMIC-CXR and IU X-ray datasets show that MARL-Rad consistently improves clinical efficacy metrics such as RadGraph, CheXbert, and GREEN scores, achieving state-of-the-art clinical efficacy performance. Further analyses show that MARL-Rad improves laterality consistency and produces more accurate and detailed reports. A blinded clinician evaluation further suggests that MARL-Rad produces reports clinically comparable to ground-truth reports.