cs.CVAug 19, 2026

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

Authors: Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze, Ezequiel De la Rosa

Organizations: Friedrich-Alexander-Universität, Erlangen-Nürnberg, Germany · University Hospital Zurich, Zurich, Switzerland · University of Zurich, Zurich, Switzerland

Abstract

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

Figures & tables

Explore similar work

Jun 12, 2026

Leptomeningeal Collateral Detection on DSA via Vessel-Graph Neural Networks

Leptomeningeal collaterals (LMCs) are an important prognostic factor in acute ischemic stroke. Existing automated methods rely on CT angiography (CTA), but individual LMCs are often too small to be resolved on CTA, limiting these methods to coarse collateral scoring. Digital subtraction angiography (DSA) visualizes individual collaterals at superior resolution, yet current assessment remains subjective, relying on manual grading scales that suffer from poor inter-rater agreement. We present a framework that formulates collateral detection as the classification of individual vessel segments on a graph derived from DSA. A hybrid graph-pixel architecture combines a topology-aware graph branch with a dense pixel branch, fused in a shared node-probability space. In a five-fold cross-validation setting, the fused model achieves a PR-AUC of 0.434, outperforming the graph-only (0.403) and pixel-only (0.362) baselines. To our knowledge, this is the first method to enable the individualization of LMCs in DSA, allowing for precise per-vessel quantitative assessment. This integration shifts DSA assessment toward objective evaluation, supporting future biomarker and pattern discovery for individual LMCs.
Feb 27, 2026

Clinically-aligned ischemic stroke segmentation and ASPECTS scoring on NCCT imaging using a slice-gated loss on foundation representations

Rapid infarct assessment on non-contrast CT (NCCT) is essential for acute ischemic stroke management. Most deep learning methods perform pixel-wise segmentation without modeling the structured anatomical reasoning underlying ASPECTS scoring, where basal ganglia (BG) and supraganglionic (SG) levels are clinically interpreted in a coupled manner. We propose a clinically aligned framework that combines a frozen DINOv3 backbone with a lightweight decoder and introduce a Territory-Aware Gated Loss (TAGL) to enforce BG-SG consistency during training. This anatomically informed supervision adds no inference-time complexity. Our method achieves a Dice score of 0.6385 on AISD, outperforming prior CNN and foundation-model baselines. On a proprietary ASPECTS dataset, TAGL improves mean Dice from 0.698 to 0.767. These results demonstrate that integrating foundation representations with structured clinical priors improves NCCT stroke segmentation and ASPECTS delineation.
Apr 19, 2026

CDSA-Net:Collaborative Decoupling of Vascular Structure and Background for High-Fidelity Coronary Digital Subtraction Angiography

Digital subtraction angiography (DSA) in coronary imaging is fundamentally challenged by physiological motion, forcing reliance on raw angiograms cluttered with anatomical noise. Existing deep learning methods often produced images with two critical clinically unacceptable flaws: persistent boundary artifacts and a loss of native tissue grayscale fidelity that undermined diagnostic confidence. We propose a novel framework termed as CDSA-Net that for the first time explicitly decouples and jointly optimizes vascular structure preservation and realistic background restoration. CDSA-Net introduces two core innovations: (i) A hierarchical geometric prior guidance (HGPG) mechanism, embedded in our coronary structure extraction network (CSENet). It synergistically combines integrated geometric prior (IGP) with gated spatial modulation (GSM) and centerline-aware topology (CAT) loss supervision, ensuring structural continuity. (ii) An adaptive noise module (ANM) within our coronary background restoration network (CBResNet). Unlike standard restoration, ANM uniquely models the stochastic nature of clinical X-ray noise, bridging the domain gap to enable seamless background intensity estimation and the complete elimination of boundary artifacts. The final subtraction is obtained by removing the restored background from the raw angiogram. Quantitatively, it significantly outperformed state-of-the-art methods in vascular intensity correlation and perceptual quality. A 25.6% improvement in morphology assessment efficiency and a 42.9% gain in hemodynamic evaluation speed set a new benchmark for utility in interventional cardiology, while maintaining diagnostic results consistent with raw angiograms. The project code is available at https://github.com/DrThink-ai/CDSA-Net.