cs.CLAug 25, 2026

MC-CXR: A Multi-Context Chest X-ray Benchmark for Context-Induced Disruption in Vision-Language Models

Authors: Junhyeok Lee, Songsoo Kim, Kyu Sung Choi

Organizations: Interdisciplinary Program in Cancer Biology, Seoul National University College of Medicine · Department of Radiology, Seoul National University Hospital · Department of Radiology, Seoul National University College of Medicine · Healthcare AI Research Institute, Seoul National University Hospital

Abstract

Vision-language models (VLMs) are increasingly used in clinical pipelines where a chest X-ray is interpreted alongside retrieved reports, preliminary notes, or prior imaging. Existing benchmarks measure whether models answer correctly in isolation, but not whether they preserve a correct image-only decision when plausible context conflicts with the image. We introduce Multi-Context Chest X-ray (MC-CXR), a benchmark of 240 cases expanded into 2,522 instances that isolates context-induced disruption through paired perturbation. Each case fixes the current image and target finding while presenting matched reliable and misleading context across text and prior CXR, with visual overlays where available. MC-CXR defines three task families and two paired metrics, the switch-to-wrong rate and the context-aligned error rate. We evaluate ten VLMs spanning open-source general, medical-domain, and closed-source systems. Image-only accuracy is necessary but insufficient. Mean switch rates range from 45.6-78.1% across misleading textual sources and 35.7-61.7% across misleading visual sources. Among switched predictions, 74.6% align with the misleading label for text versus 17.6% for visual context, a 57.0-point gap (95% CI 50.9-62.8). This text-visual asymmetry is observed under the standardized direct-answer protocol. The dataset is available on PhysioNet.

Figures & tables

Appendix figures & tables1 asset

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 17, 2026

Medical Context Distorts Decisions in Clinical Vision Language Models

Vision-language models (VLMs) are increasingly proposed for clinical decision support, yet their reliability in real-world scenarios that require integrating both visual and textual context from medical records remains poorly characterized. This paper identifies three failure modes: (1) modality over-reliance on text over images, (2) spurious reliance on irrelevant clinical history, and (3) prompt sensitivity across semantically equivalent inputs. We evaluate a diverse set of general-domain and medically-tuned open and closed VLMs on chest x-ray tasks using MIMIC-CXR. By systematically manipulating image-text alignment, clinical history, and prompt formulations, we found that VLM decisions are dominated by the text modality, even when visual evidence is available. Moreover, we observed that VLMs are heavily influenced by irrelevant reports, while minor prompt changes can reverse correct image-based predictions. Our findings underscore the need for explicit safeguards and stress-testing before considering the use of these models in clinical practice.
Jun 19, 2026

CheXpercept: A Benchmark for Evaluating Expert-Level Lesion Perception in Chest X-rays

The evaluation of vision-language models (VLMs) for chest X-ray (CXR) analysis has largely been limited to disease-presence classification without visual grounding. Such evaluations fail to verify the expert-level lesion perception necessary to ensure the clinical reliability of VLMs. To address these limitations, we introduce CheXpercept, a sequential, multi-level perception benchmark that mirrors a radiologist's cognitive workflow across coarse-level detection, fine-level contour evaluation and revision, and semantic-level attribute extraction. To ensure high clinical fidelity at scale, we construct the dataset using a semi-automated generation pipeline paired with a review by six medical experts. CheXpercept contains 10,400 QA items derived from 2,100 CXRs, covering seven clinically critical pulmonary and cardiac lesions. To demonstrate the current landscape of VLM perception, we benchmark 14 general and medical VLMs on CheXpercept. The models achieve adequate performance only at the coarse level, with accuracy degrading precipitously on deeper visual tasks. Notably, medical VLMs show almost no perceptual advantage over their general-domain counterparts, highlighting a systemic flaw in current domain adaptation. The code and dataset will be publicly available.
May 7, 2026

CXR-ContraBench: Benchmarking Negated-Option Attraction in Medical VLMs

When a chest X-ray shows consolidation but the question asks which finding is present, a medical vision-language model may answer "No consolidation." This is more than an incorrect choice: it is a polarity reversal that emits a clinical statement contradicting the image. We study this failure as negated-option attraction, where a model is drawn to a negated answer option even when it conflicts with both the visual evidence and the question. We introduce CXR-ContraBench (Chest X-Ray Contradiction Benchmark), a diagnostic benchmark spanning internal ReXVQA slices and external OpenI and CheXpert protocols. The benchmark centers on present-finding questions, where selecting "No X" despite visible X creates the main clinical risk, and uses absent-finding questions as secondary tests of whether models copy negated wording. Across CheXpert protocols, the failure is substantial and persistent. On a strict direct presence probe, MedGemma and Qwen2.5-VL reach only 31.49% and 30.21% accuracy, respectively; on a matched 135,754-record CheXpert training-split protocol, both models select negated options on over 62% of presence questions. Chain-of-thought prompting reduces some presence-side reversals but does not eliminate them and can amplify absence-side contradictions. Finally, QCCV-Neg (Question-Conditioned Consistency Verifier for Negation) deterministically repairs the measured polarity-confused subset without retraining, raising MedGemma and Qwen2.5-VL to 96.60% and 95.32% accuracy on the direct presence probe. These results show that standard accuracy can hide a clinically meaningful inference-time polarity failure. Source code and benchmark construction scripts are available at https://github.com/fangzr/cxr-contrabench-code.