cs.AIAug 25, 2026

Neurosymbolic Alignment for Physiologically-Safe Clinical Language Models

Authors: Abdulhady Abas Abdullah, Erik Cambria, Milena Zivkovic

Organizations: Artificial Intelligence and Innovation Centre, University of Kurdistan Hewlêr, Erbil, Iraq · MIT Media Lab, Massachusetts Institute of Technology, Cambridge, MA 02139, USA · Department of Physics, Faculty of Science, University of Kragujevac, 34000 Kragujevac, Serbia

Abstract

Clinical LLMs can generate recommendations that are factually plausible yet physiologically unsafe. We investigate whether safety alignment can be improved by grounding preference optimization in structured physiological knowledge rather than text-only supervision. Methods: We propose Neurosymbolic Alignment, a training-time framework that couples a 7B clinical LLM with an HGNN-based Physiological World Model over an 847K-node biomedical knowledge graph. Candidate responses are scored using homeostatic constraints, multi-hop path plausibility, and drug-interaction penalties, and the resulting rankings drive iterative on-policy ORPO updates. Evaluation is performed on the Clinical Safety Benchmark (CSB), a 2,500-scenario benchmark for physiological constraint violations in generative clinical reasoning. Results: Relative to ORPO, the proposed method improves CSS from 69.5% to 90.8% (+21.3 pp), reduces physician-evaluated HR from 14.1% to 5.1% on the blinded subset, and improves DID from 72.8% to 91.6%. These gains are corroborated by an HGNN-independent Rule-Engine Safety Score (RSS: 86.4%, +21.2 pp over ORPO; r=0.97 concordance with CSS). The method also exceeds GPT-4 (5-shot) on all safety metrics despite a 10x parameter disadvantage, and outperforms an inference-time self-correction pipeline (SFT+SelfCorrect) by 11.4 pp CSS. Under synthetic EHR-style noise, 84.2% CSS is retained. Ablation analysis shows that HGNN scoring (-16.2 pp) and iterative training (-11.5 pp) are the dominant contributors. PhysioScore calibration against 200 clinician labels yielded ECE = 0.038 and kappa = 0.91. Conclusion: Training-time physiological grounding produces measurable and independently verifiable safety improvements in open-weight clinical LLMs under controlled evaluation. External validation on real clinical data is required to determine whether these gains transfer to deployment settings

Figures & tables

Appendix figures & tables22 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. When Medical Safety Alignment Fails: A Benchmark for Evaluating LLMs on High-Risk Medical Queries

    May 26, 2026Yige Li, Jun Sun, Wei Zhao +5LLM Safety BenchmarksHealthcare

  2. SafeMed-R1: Clinician-Audited Safety and Ethics Alignment for Medical Large Language Models

    May 27, 2026Chao Ding, Mouxiao Bian, Tianbin Li +12HealthcareLLM Auditing

  3. Alignment Plausibility: A New Standard for Assuring AI in Healthcare

    Jul 8, 2026Gwydion Williams, Sara Zannone, Bilal A MateenLLM AlignmentHealthcare