PAGS: Autofocusing Photoacoustic Tomography via Speed-of-Sound-Adaptive Gaussian Splatting

Authors: Jiarui Ge, Jintao Ma, Bangxu Fan, Jinyan Zhang, Xiaokang Yang, Shuai Na, Xiaoyun Yuan

Organizations: MoE Key Lab of Artificial Intelligence, Institute of AI, School of Computer Science, Shanghai Jiao Tong University, Shanghai, China. · National Biomedical Imaging Center, College of Future Technology, Peking University, Beijing, China. · Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China. · Key Laboratory of Machine Perception, Ministry of Education, Beijing, China. · PKU–Nanjing Institute of Translational Medicine, Nanjing, China.

Abstract

Photoacoustic computed tomography (PACT) combines optical absorption contrast with acoustic detection for high-resolution deep-tissue imaging. A persistent challenge is that unknown speed-of-sound (SoS) heterogeneity changes acoustic time-of-flight, causing defocusing artifacts when reconstruction assumes a uniform SoS. Existing SoS-adaptive methods either rely on calibrated acoustic priors or optimize dense physical medium models, which becomes expensive and difficult to scale in 3D. We propose PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting. PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and replaces explicit medium recovery with a compact anisotropic path-averaged SoS (ASoS) field parameterized by spherical harmonic probes. This latent propagation field directly controls source-to-transducer arrival-time alignment, while an analytic Gaussian acoustic projection maps the source representation to transducer signals efficiently. The resulting closed-loop signal-domain optimization jointly updates the Gaussian PA source parameters and the ASoS field from measured data, without calibrated SoS priors. Experiments on simulated and physical phantom data demonstrate improved reconstruction sharpness under heterogeneous acoustic media, robustness to sparse-view sampling, and computational benefits from the analytic Gaussian projection.

Figures & tables

Explore similar work

Apr 17, 2026

Self-Supervised Angular Deblurring in Photoacoustic Reconstruction via Noisier2Inverse

Photoacoustic tomography (PAT) is an emerging imaging modality that combines the complementary strengths of optical contrast and ultrasonic resolution. A central task is image reconstruction, where measured acoustic signals are used to recover the initial pressure distribution. For ideal point-like or line-like detectors, several efficient and fast reconstruction algorithms exist, including Fourier methods, filtered backprojection, and time reversal. However, when applied to data acquired with finite-size detectors, these methods yield systematically blurred images. Although sharper images can be obtained by compensating for finite-detector effects, supervised learning approaches typically require ground-truth images that may not be available in practice. We propose a self-supervised reconstruction method based on Noisier2Inverse that addresses finite-size detector effects without requiring ground-truth data. Our approach operates directly on noisy measurements and learns to recover high-quality PAT images in a ground-truth-free manner. Its key components are: (i) PAT-specific modeling that recasts the problem as angular deblurring; (ii) a Noisier2Inverse formulation in the polar domain that leverages the known angular point-spread function; and (iii) a novel, statistically grounded early-stopping rule. In experiments, the proposed method consistently outperforms alternative approaches that do not use supervised data and achieves performance close to supervised benchmarks, while remaining practical for real acquisitions with finite-size detectors.
Mar 23, 2026

PA-SFM: Tracker-free differentiable acoustic radiation for freehand 3D photoacoustic imaging

Three-dimensional (3D) handheld photoacoustic tomography typically relies on bulky and expensive external positioning sensors to correct motion artifacts, which severely limits its clinical flexibility and accessibility. To address this challenge, we present PA-SFM, a tracker-free framework that leverages exclusively single-modality photoacoustic data for both sensor pose recovery and high-fidelity 3D reconstruction via differentiable acoustic radiation modeling. Unlike traditional structure-from-motion (SFM) methods based on visual features, PA-SFM integrates the acoustic wave equation into a differentiable programming pipeline. By leveraging a high-performance, GPU-accelerated acoustic radiation kernel, the framework simultaneously optimizes the 3D photoacoustic source distribution and the sensor array pose via gradient descent. To ensure robust convergence in freehand scenarios, we introduce a coarse-to-fine optimization strategy that incorporates geometric consistency checks and rigid-body constraints to eliminate motion outliers. We validated the proposed method through both numerical simulations and in-vivo rat experiments. The results demonstrate that PA-SFM achieves sub-millimeter positioning accuracy and restores high-resolution 3D vascular structures comparable to ground-truth benchmarks, offering a low-cost, software-defined solution for clinical freehand photoacoustic imaging. The source code is publicly available at https://github.com/JaegerCQ/PA-SFM.
Jul 28, 2026

Matrix-Free Photoacoustic Image Reconstruction via Sensor-Token Self-Attention

Photoacoustic tomography (PAT) combines the optical absorption contrast of biological tissue with the spatial resolution of ultrasound, yet recovering the initial pressure distribution from sparse-view sensor measurements remains an ill-posed inverse problem. Iterative compressive-sensing solvers and unrolled deep networks both retain a dependence on the system matrix at inference, which leaves real-time clinical reconstruction computationally expensive. This paper proposes the Sensor Attention Network (SAN), a Transformer-based architecture that treats the full time series of each sensor as a token and maps raw measurements directly to the reconstructed image without invoking the system matrix at inference. For training and benchmarking, an analytical k-space H-matrix is constructed and validated against the k-Wave pseudo-spectral solver under matched geometry, achieving a mean per-sensor Pearson correlation of 0.919 +/- 0.049, with k-space apodization and Gaussian temporal damping acting synergistically to reduce the energy-normalized mismatch by 49%. Trained with a vessel-weighted loss on 488 augmented samples and evaluated on 46 held-out samples against ISTA, split-Bregman total variation (SBTV), and learned ISTA (LISTA), SAN attains the highest mean SSIM (0.522) and PSNR (22.09 dB) and the lowest NMSE (0.233). Paired t-tests and Wilcoxon signed-rank tests confirm the superiority of SAN over LISTA on PSNR, NMSE, and Pearson correlation at p < 1e-8, and over ISTA and SBTV on all fidelity metrics. By bypassing the H-matrix at inference, SAN reduces reconstruction time by at least an order of magnitude, supporting real-time PAT reconstruction.