cs.CVAug 26, 2026

Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

Authors: Atle Bjørnerud, Till Schellhorn, Thor H. Skattør, Terje Nome, Jon André Ottesen, Anne Hege Aamodt, Bradley J MacIntosh

Organizations: Computational Radiology & Artificial Intelligence Unit, Department of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway · Center for Lifespan Changes in Brain and Cognition, Department of Psychology, University of Oslo, Oslo, Norway · Division of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway · Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway · Department of Neurology, Oslo University Hospital, Oslo, Norway · Department of Neuromedicine and Movement Science, The Norwegian University of Science and Technology, Trondheim, Norway · Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Canada · Hurvitz Brain Sciences, Sandra Black Centre for Brain Resilience & Recovery, Physical Sciences Platform, Sunnybrook Research Institute, Canada

Abstract

Objective: Diffusion-weighted MRI (DWI-MRI) is the gold standard for visualizing and quantifying acute ischaemic stroke (AIS). Although deep learning methods can accurately segment AIS lesions, the optimal image inputs and model architecture remain uncertain. We evaluated whether accurate AIS lesion segmentation can be achieved using a pragmatic deep learning approach with minimal preprocessing and clinically feasible inference times. Materials and Methods: Self-configured nnU-Net models were trained on 1,744 DWI cases from local, national, and open-access datasets and tested on 436 cases. Four experimental conditions were evaluated using five-fold cross-validation: with or without brain extraction and using either DWI alone or DWI plus apparent diffusion coefficient (ADC) images as inputs. Two architectures were compared: the baseline nnU-Net (base) and a residual encoder nnU-Net (ResEnc). Performance was benchmarked against the DeepISLES ensemble model from the 2022 ISLES challenge. Results: In the test set (n=436), the base model achieved a median (IQR) Dice similarity coefficient (DSC) of 0.84 (0.19). For the base model, only two of six pairwise comparisons between input configurations showed significant differences. ResEnc produced small but significant improvements in DSC compared with the base model for DWI, DWI+brain extraction, and DWI+ADC inputs (all p<0.02), but not for DWI+ADC+brain extraction (p>0.50). The base model significantly outperformed DeepISLES, particularly in patients with smaller infarct volumes (signed-rank test, p<0.01). Conclusions: A baseline nnU-Net trained on DWI alone, without preprocessing, enabled fast and accurate AIS lesion segmentation. This streamlined approach may facilitate clinical research and support acute stroke imaging workflows

Explore similar work

Jan 13, 2026

Automated Lesion Segmentation of Stroke MRI Using nnU-Net: A Comprehensive External Validation Across Acute and Chronic Lesions

Accurate and generalisable segmentation of stroke lesions from magnetic resonance imaging (MRI) is essential for advancing clinical research, prognostic modelling, and personalised interventions. Although deep learning has improved automated lesion delineation, many existing models are optimised for narrow imaging contexts and generalise poorly to independent datasets, modalities, and stroke stages. Here, we systematically evaluated stroke lesion segmentation using the nnU-Net framework across multiple heterogeneous, publicly available MRI datasets spanning acute and chronic stroke. Models were trained and tested on diffusion-weighted imaging (DWI), fluid-attenuated inversion recovery (FLAIR), and T1-weighted MRI, and evaluated on independent datasets. Across stroke stages, models showed robust generalisation, with segmentation accuracy approaching reported inter-rater reliability. Performance varied with imaging modality and training data characteristics. In acute stroke, DWI-trained models consistently outperformed FLAIR-based models, with only modest gains from multimodal combinations. In chronic stroke, increasing training set size improved performance, with diminishing returns beyond several hundred cases. Lesion volume was a key determinant of accuracy: smaller lesions were harder to segment, and models trained on restricted volume ranges generalised poorly. MRI image quality further constrained generalisability: models trained on lower-quality scans transferred poorly, whereas those trained on higher-quality data generalised well to noisier images. Discrepancies between predictions and reference masks were often attributable to limitations in manual annotations. Together, these findings show that automated lesion segmentation can approach human-level performance while identifying key factors governing generalisability and informing the development of lesion segmentation tools.
Jul 3, 2026

EPRA U-Net: An Efficient Pyramid Residual Attention Framework for Accurate Infarct Segmentation in Diffusion-Weighted MRI

Objective: Accurate identification of acute ischemic infarcts on diffusion-weighted magnetic resonance imaging (DWI) is a critical prerequisite for reliable lesion quantification and effective clinical decision support in the management of cerebrovascular events. Methods: This study presents EPRA U-Net (Efficient Pyramid Residual Attention U-Net), a task-specific integrated architecture for efficient and accurate infarct segmentation of DWI images. In the proposed architecture, an EfficientNet-based encoder was used as a hierarchical feature extractor with a minimized parameterization. In addition, a Residual-Recurrent (R2) block (recurrent unrolling step t = 2, following the original formulation) and Atrous Spatial Pyramid Pooling (ASPP) were integrated to enhance the performance of spatial dependency modeling. Additionally, a dual attention mechanism was incorporated to highlight lesion-related activations while concurrently enabling the suppression of extraneous background responses. To prioritize lesion detection consistent with clinical imperative, a Tversky loss function was adopted, emphasizing the sensitivity of detection over its specificity during the optimization process. Results: Experimental evaluations were conducted utilizing an in-house dataset comprising 167 patients with 4,895 DWI slices; subsequently, the performance of the proposed EPRA U-Net was assessed in comparison with state-of-the-art models, specifically UNet++, DeepLabV3+, and TransUNet. The experimental results suggest that EPRA U-Net attained superior performance, evidenced by a pixel-aggregated Dice of 0.8984, a per-sample Dice of 0.9469, an IoU of 0.8155, a Recall of 0.8887, a Lesion F1 of 0.9378, and an HD95 of 11.62 px. Furthermore, a clear reduction in the rate of missed lesions, specifically by 16%, 25%, and 29%, was observed when compared with UNet++, DeepLabV3+, and TransUNet, respectively.
Aug 24, 2026

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions (≤7\le 7 days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L (k=5k=5) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)