cs.CVSep 3, 2026

ARCOS: Zero-shot Boundary Localization for Corneal Layer Segmentation Across Optical Coherence Tomography Devices

Authors: Nuno Vivas BrásBenjamin MemmiMaëlle BouhassaneCristina GeorgeonVincent BorderieKarsten PlamannAnatole Chessel

Organizations: Laboratoire d’Optique et Biosciences, CNRS, INSERM, ´Ecole polytechnique, Institut Polytechnique de Paris, Palaiseau, France · GRC 32, Transplantation et Th´erapies Innovantes de la Corn´ee, Sorbonne Universit´e, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France

Abstract

Accurate segmentation of corneal layers in optical coherence tomography (OCT) is essential for quantitative assessment of corneal morphology, including layer thickness and structural changes associated with disease or surgery. However, automatic segmentation remains challenging because corneal interfaces are thin, affected by speckle noise, and variable across acquisition devices. In this work, we propose ARCOS, a patch-based zero-shot boundary localization framework for corneal layer segmentation in clinical anterior-segment OCT images. Rather than performing conventional region classification, the method predicts boundary heatmaps for the main corneal interfaces from overlapping native-resolution patches. Patch-level predictions are stitched across the full B-scan and converted into boundary locations to obtain continuous, anatomically ordered layer segmentations. The network combines multi-scale feature fusion with a self-conditioned refinement module that uses intermediate boundary information to improve local heatmap predictions while preserving spatial detail. The method was evaluated on clinical OCT images acquired from multiple devices and compared with representative segmentation baselines using boundary localization and derived thickness metrics. The proposed method achieved an off-by-one boundary localization accuracy of 95.1% and a mean absolute boundary error of 0.514 pixels on the matched-device test set. In zero-shot cross-device evaluation, it maintained an average off-by-one accuracy of 84.3% and a mean absolute boundary error of 0.855 pixels across unseen acquisition devices, outperforming the baseline models. Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the method's use for quantitative corneal OCT analysis.

Explore similar work

Jul 17, 2026cs.CV

Spatial Normalization for Cross-Domain Retinal Layer Segmentation in Optical Coherence Tomography

Retinal layer segmentation in Optical Coherence Tomography (OCT) is a fundamental step for extracting quantitative biomarkers of retinal structure. Indeed, there is a growing interest in the analysis of OCTs in the context of neurodegenerative diseases. However, segmentation remains challenging due to speckle noise, shadowing artifacts, low contrast between adjacent layers, anatomical variability across subjects, and domain shifts arising from different acquisition protocols and clinical populations. While deep learning methods have achieved remarkable performance, their robustness and generalization across heterogeneous datasets remain limited. In this work, we investigate the role of spatial normalization as a preprocessing strategy to mitigate geometric domain shifts and improve the consistency of retinal layer segmentation. Inspired by standard practices in neuroimaging, we introduce a fovea-centered normalization framework that aligns OCT volumes into a common anatomical reference. We perform a comprehensive evaluation of state-of-the-art deep learning architectures. To provide a comprehensive assessment of segmentation quality, we combine conventional overlap-based metrics at B-scan level with topology-aware metrics at A-scan level and thickness-based measures at the en-face level. In cases where a ground truth is not available, we propose topology violation quantitative metrics that do not require ground truth annotations and a thickness-based qualitative assessment that captures structural consistency and clinically relevant patterns at the en-face level. The results demonstrate the importance of spatial normalization in OCT segmentation pipelines toward the development of robust and clinically meaningful retinal analysis tools, enabling reliable biomarker extraction and downstream computational analysis in neurodegenerative research.
Iker Moran-Cavero, Monica Hernandez, Elvira Mayordomo +4
Jun 30, 2026cs.CV

Fully Automated High-Precision Segmentation of Retinal Atrophy and Ellipsoid Zone Thickness in OCT: A Reliable Tool for Real-World GA Monitoring

Geographic atrophy (GA) secondary to age-related macular degeneration (AMD) requires precise monitoring of relevant structural biomarkers to assess disease stage, progression, and treatment response. This paper presents a fully automated, deep learning-based framework for the high-precision, pixel-wise segmentation of key biomarkers in optical coherence tomography (OCT) imaging: retinal pigment epithelium (RPE) loss, ellipsoid zone (EZ) loss, and EZ thinning. The proposed pipeline uses three specialized semantic segmentation models to delineate RPE loss, EZ boundaries (including interruptions), and Bruch's membrane. To ensure robustness and generalizability, the models were developed on a diverse dataset of 298 SD-OCT volumes representing the full phenotypic spectrum of AMD (GA:222, intermediate AMD: 40, neovascular AMD: 17, healthy: 19) and validated on an independent external dataset (n=43). The comprehensive evaluation was further strengthened using additional datasets to assess repeatability, inter-reader reliability, the impact of B-scan density on measurement accuracy, and subgroup performance stratified by lesion size. Results demonstrated high segmentation accuracy (Dice RPE loss: 0.88, Dice EZ loss: 0.87, Pearson's r > 0.99). Total EZ thickness measurements exhibited a sub-pixel average deviation of 2.15 μmμm, and segmentation reliability was confirmed by a strong reproducibility score (ICC > 0.98). By accurately and consistently quantifying outer photoreceptor degeneration and RPE loss, this fully automated framework provides a highly reliable tool for GA assessment in both clinical trials and routine real-world ophthalmic care.
Wolf-Dieter Vogl, Hlynur Skulason, Oliver Leingang +3
Jul 20, 2026cs.CV

PC-Seg: Progressive Cross-View Consistency for 3D OCT Segmentation from Sparse 2D Annotations

Volumetric segmentation of optical coherence tomography (OCT) images is essential for diagnosing ocular diseases but requires labor-intensive voxel-wise annotations. While semi-supervised learning (SSL) can reduce annotation costs, most existing methods process data slice by slice and fail to exploit the inherent 3D spatial context. We propose PC-Seg, a progressive cross-view consistency framework that learns high-accuracy 3D segmentation models from sparse 2D annotations. Unlike conventional multi-view approaches, PC-Seg uses a single 2D model to learn cross-view consistency from standard B-scans and orthogonal slices, thereby generating reliable volumetric pseudo-labels. These pseudo-labels are then distilled into a 3D model, followed by a co-training stage in which the 2D and 3D models mutually refine each other through ensemble pseudo-labeling. Experiments on the MSHC and Duke DME datasets demonstrate that PC-Seg achieves accuracy comparable to fully supervised learning while using labels for only about 0.7% of the training data, outperforming state-of-the-art semi-supervised and retinal layer segmentation methods. Our code is publicly available at https://github.com/gsisaoki/pc-seg-official.
Tsubasa Konno, Takahiro Ninomiya, Yukun Zhou +6