Organizations: University of British Columbia, Vancouver, Canada · Hangzhou Dianzi University, Hangzhou, China · ShanghaiTech University, Shanghai, China · Griffith University, Gold Coast, Australia
High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr
Figures & tables
Figure 1: MedGSSR introduces a paradigm shift for Medical 3D Super-Resolution. Left: Existing self-supervised methods (relying on isolated optimization) and neural implicit networks (relying on coordinate querying) fail to simultaneously achieve fast inference, robust generalization, and high-quality reconstruction. MedGSSR introduces a generalized feed-forward 3DGS paradigm that explicitly satisfies all three clinical requirements. Right: Cross-dataset Visual comparisons (trained on MSD, tested on HCP) at 2× and 4× upsampling scales. Compared to baselines that produce geometric artifacts or over-smoothed textures, MedGSSR accurately restores high-frequency anatomical structures with the lowest error (dark blue in difference maps) while accelerating inference by an order of magnitude.
Figure 2: Overview of MedGSSR. Given an LR input volume, the Pyramid Anatomical Encoder (PAE) built on a 3D U-Net extracts a coarse feature map and a 2× upsampled fine feature map via input-residual connection and PixelShuffle. The Hierarchical Gaussian Projector (HGP) performs sub-voxel Gaussian decomposition by predicting multiple Gaussian primitives per voxel with lightweight MLP heads, producing structural Gaussians from the coarse stream and textural Gaussians from the fine stream. These primitives are then aggregated by the Differentiable Gaussian Voxelizer (DGV) through differentiable rasterization to form a continuous volumetric intensity field, from which the HR volume is rendered.
Paradigm
Methods
2×
3×
4×
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
Traditional
Trilinear
33.31
0.9670
0.1134
30.77
0.9377
0.2026
29.08
0.9100
0.2558
Cubic
33.99
0.9725
0.0981
31.13
0.9422
0.2083
29.27
0.9118
0.2711
Self-supervised
CuNeRF [ 6 ]
32.60
0.9715
0.0513
30.07
0.9524
0.0878
28.26
0.9309
0.1271
Neural Implicit
ArSSR [ 29 ]
32.87
0.9742
0.0581
29.56
0.9442
0.0730
28.51
0.9315
0.0853
FF-3DGS
MedGSSR
35.91
0.9821
0.0337
33.97
0.9700
0.0706
32.10
0.9541
0.1246
Table 1: Comparison of intra-domain 3D super-resolution performance on the MSD (MRI) dataset. Models are both trained and evaluated on the MSD dataset.
Paradigms
Methods
2×
3×
4×
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
Traditional
Trilinear
37.51
0.9530
0.1561
34.83
0.9166
0.2302
33.84
0.8843
0.3291
Cubic
37.64
0.9636
0.1179
35.14
0.9237
0.2325
34.09
0.8888
0.3263
Self-supervised
CuNeRF [ 6 ]
37.12
0.9654
0.1201
35.42
0.9235
0.1863
33.94
0.8957
0.2456
NAB-GS [ 20 ]
-
-
-
-
-
-
34.13
0.9518
-
Neural Implicit
ArSSR [ 29 ]
38.53
0.9644
0.0914
36.02
0.9413
0.1576
34.63
0.9244
0.2261
Table 2: Comparison of intra-domain 3D super-resolution performance on the MELA (CT) dataset. Models are both trained and evaluated on the MELA dataset.
Figure 3: Qualitative comparison of intra-domain 3DSR on MELA (CT) and MSD (MRI). Axial views are shown at 2× , 3× and 4× scales. MedGSSR better recovers fine-grained skeletal and vascular structures, avoiding the smoothing artifacts of ArSSR and the noise commonly observed in other methods.
Paradigms
Methods
2×
3×
4×
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
Traditional
Trilinear
36.45
0.9425
0.1048
33.75
0.9221
0.1634
30.76
0.9026
0.2675
Cubic
36.47
0.9588
0.0885
34.01
0.9289
0.1454
31.86
0.9125
0.2483
Self-supervised
CuNeRF [ 6 ]
36.91
0.9716
0.0724
34.48
0.9547
0.1362
33.12
0.9382
0.1587
Neural Implicit
ArSSR [ 29 ]
36.07
0.9655
0.0615
33.56
0.9429
0.0892
31.87
0.9220
0.1141
FF-3DGS
MedGSSR
40.81
0.9849
0.0674
37.94
0.9702
0.0945
35.84
0.9533
0.1253
Table 3: Comparison of cross-domain 3D super-resolution performance on the HCP (MRI). Models are trained on the MSD dataset and evaluated on the HCP dataset.
Paradigms
Methods
4×
6×
8×
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
Traditional
Trilinear
31.96
0.9404
0.1051
26.73
0.9027
0.1706
23.96
0.8436
0.2605
Cubic
32.88
0.9407
0.0898
28.51
0.9189
0.1654
26.07
0.8579
0.2517
Self-supervised
CuNeRF [ 6 ]
38.03
0.9628
0.1252
33.76
0.9164
0.2465
30.50
0.8690
0.3510
Neural Implicit
ArSSR [ 29 ]
35.92
0.9471
0.0918
32.88
0.9332
0.1191
29.38
0.8994
0.2145
FF-3DGS
MedGSSR
41.20
0.9818
0.0468
37.74
0.9698
0.0765
35.24
0.9233
0.1253
Table 4: Comparison of cross-domain 3D super-resolution performance on the UHRCT (CT). Models are trained on the MELA dataset and evaluated on the UHRCT dataset.
Figure 4: Qualitative comparison of cross-domain 3DSR on the HCP (MRI). All models are trained on the MSD and evaluated on the unseen HCP. The error maps (dark blue indicates lower error) highlight that MedGSSR produces the sharpest anatomical details with minimal reconstruction deviation compared to the baselines.
Methods
CSF
GM
WM
dGM
BS+CB
Average
Trilinear
0.4937
0.7265
0.8617
0.8098
0.6701
0.7124
Cubic
0.5410
0.7616
0.8860
0.8616
0.8518
0.7804
CuNeRF [ 6 ]
0.3668
0.5330
0.7347
0.1285
0.0458
0.3618
ArSSR [ 29 ]
0.6782
0.8318
0.9187
0.9140
0.5612
0.7908
Ours (MedGSSR)
0.5779
0.8406
0.9295
0.9407
0.8006
0.8178
Table 5: Comparison of Dice scores. The segmentation is performed using a pre-trained nnUNet on 4× super-resolved MRI volumes (HCP). Best results are highlighted in bold.
Figure 5: Downstream brain tissue segmentation on the HCP dataset ( 4× SR). The structural fidelity provided by MedGSSR translates to precise automated boundary delineation, avoiding the tissue-bleeding artifacts observed in the others.
Figure 6: Ablation on Structure-Texture Decoupling on the HCP dataset ( 4× SR). The coarse branch captures global anatomy, and adding the fine branch restores high-frequency textures, improving sharpness and quantitative metrics.
Settings
PSNR ↑
SSIM ↑
LPIPS ↓
m=1
35.98
0.9760
0.0423
m=2
36.06
0.9771
0.0388
m=4 (Default)
36.60
0.9870
0.0363
m=8
36.52
0.9862
0.0365
Table 6: Ablation on sub-voxel count m under intra-domain setting on the HCP dataset (4 × SR). Setting m=4 delivers the best balance between accuracy and computational cost. Best results are highlighted in bold.
Variants
PSNR ↑
SSIM ↑
LPIPS ↓
Ours
35.84
0.9533
0.1253
Ours + FFT Loss
35.72
0.9472
0.1078
Ours w/ 1σ truncation
31.05
0.9142
0.1608
Ours w/ 50% training data
34.26
0.9405
0.1452
Ours w/ 75% training data
35.49
0.9512
0.1283
Table 7: Ablation study on effects of frequency-domain supervision, Gaussian truncation radius, and training data under the cross-domain setting on the HCP dataset ( 4× SR). Best results are highlighted in bold.
Figure 7: Additional visual comparisons for intra-domain 3D super-resolution on the MSD (MRI) dataset. Results are shown across axial, coronal, and sagittal views at 2 × , 3 × , and 4 × upsampling scales, with zoomed-in regions for detailed inspection. From left to right: Trilinear, Cubic, CuNeRF, ArSSR, Ours, and GT. MedGSSR better preserves cortical folds, tissue boundaries, and local anatomical details than competing methods.
Figure 8: Additional visual comparisons for intra-domain 3D super-resolution on the MELA (CT) dataset. Results are shown across axial, coronal, and sagittal views at 2 × , 3 × , and 4 × upsampling scales, with zoomed-in regions for detailed inspection. From left to right: Trilinear, Cubic, CuNeRF, ArSSR, Ours, and GT. Compared with the baselines, MedGSSR produces clearer boundaries and more faithful recovery of fine anatomical structures across all super-resolution.
Figure 9: Additional visual comparisons for cross-domain 3D super-resolution on the unseen HCP (MRI) dataset [ 26 ] . Models are trained exclusively on the MSD dataset and evaluated at 2 × , 3 × , and 4 × upsampling scales. Results are shown across axial, coronal, and sagittal views, with zoomed-in regions for detailed inspection. Compared with competing methods, MedGSSR better preserves tissue boundaries, cortical structures, and local anatomical details under dataset shift.
Figure 10: Additional visual comparisons for cross-dataset 3D super-resolution on the unseen UHRCT (CT) dataset [ 7 ] . Models are trained on MELA and evaluated at 4 × , 6 × , and 8 × upsampling scales. Following the benchmark protocol, results are shown on the axial plane, with zoomed-in regions for detailed inspection. MedGSSR remains more robust than competing methods as the resolution gap increases, preserving clearer anatomical boundaries and finer local structures.
Methods
PSNR ↑
SSIM ↑
LPIPS ↓
FLOPs (G)
Peak Mem. (GB)
Params (M)
Inference Time (ms)
MTVNet
34.16±2.86
0.9246±0.0267
0.1368±0.0416
1359.50
1.75
22.61
1083.18
SuperFormer
33.87±3.02
0.9142±0.0273
0.1446±0.0435
1888.20
2.06
19.66
1592.91
CuNeRF
33.12±3.56
0.9382±0.0365
0.1587±0.0557
2061.58
0.12
0.98
259.76
ArSSR
31.87±3.37
0.9220±0.0324
0.1141±0.0513
955.15
8.15
6.28
105.98
MedGSSR(Ours)
35.84±2.73
0.9533±0.0224
0.1253±0.0378
385.87
1.29
18.13
56.52
Table 8: Extended quantitative and computational comparison under cross-domain 4× 3D SR on the HCP dataset. In addition to the baselines reported in the main paper, MTVNet and SuperFormer are included as transformer-based baselines. Computational cost is reported for all methods. Best and second-best results are bolded and underlined, respectively.
Figure 11: Additional visual comparisons for downstream brain tissue segmentation under cross-domain on the unseen HCP dataset based on 4 × super-resolved MRI volumes. Results are shown across axial, coronal, and sagittal views, with zoomed-in regions for detailed inspection. Compared with competing methods, MedGSSR yields segmentation masks that are more consistent with the ground truth, with clearer boundaries and more faithful anatomical structures.
Figure 12: Additional visual comparisons for downstream brain tissue segmentation under cross-domain on the unseen HCP dataset based on 8 × super-resolved MRI volumes. Results are shown across axial, coronal, and sagittal views. This more challenging setting serves as an additional stress test beyond the main experiments. As the upsampling factor increases, the competing methods exhibit substantial degradation in structural consistency, whereas MedGSSR still preserves more faithful anatomical regions and produces segmentation masks that remain noticeably closer to the ground truth.
Variants
PSNR ↑
SSIM ↑
LPIPS ↓
Ours
37.31
0.9362
0.1472
Ours w/ m=1
36.42
0.9234
0.1564
Ours w/ 1σ truncation
33.47
0.8971
0.1827
Ours w/ 75% training data
37.04
0.9338
0.1502
Table 9: Additional CT ablation on the MELA dataset under the intra-domain 4× 3D SR setting. The results show trends consistent with the MRI ablations and evaluate sub-voxel decomposition, Gaussian truncation radius, and reduced training data. Best results are highlighted in bold.
Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA · Department of Medicine, University of Florida, Gainesville, FL, USA · Department of Biomedical Engineering, University of Florida, Gainesville, FL +2
Knight Foundation School of Computing and Information Sciences Florida International University Miami, FL 33199, USA · University of Florida Gainesville, FL 32611, USA · Department of Computer Science California State University, East Bay Hayward, CA 94542, USA