cs.CVSep 7, 2026

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

Authors: Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng, Wei-Chun Wang, Shih-Sheng Chang

Organizations: Artificial Intelligence and Robotics Innovation Center, China Medical University Hospital, Taichung, Taiwan · Division of Cardiovascular Medicine, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan · Department of Neurology, China Medical University Hospital, China Medical University, Taichung, Taiwan · Neuroscience and Brain Disease Center, China Medical University, Taichung, Taiwan · School of Medicine, China Medical University, Taichung, Taiwan

Abstract

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-F1F_1. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-F1F_1 (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 18, 2026

DeepCORO-CLIP: A Multi-View Foundation Model for Comprehensive Coronary Angiography Video-Text Analysis and External Validation

Coronary angiography is the reference standard for evaluating coronary artery disease, yet visual interpretation remains variable between readers. Existing artificial intelligence methods typically analyze single frames or projections and focus mainly on stenosis, limiting comprehensive coronary assessment. We present DeepCORO-CLIP, a multi-view foundation model trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute and externally validated on 4,249 studies from the University of California, San Francisco. DeepCORO-CLIP integrates multiple projections with attention-based pooling for study-level assessment across diagnostic, prognostic, and disease progression tasks. For significant stenosis detection, the model achieved an AUROC of 0.888 internally and 0.89 on external validation. Mean absolute error against core laboratory quantitative coronary angiography was 13.6%, lower than clinical reports at 19.0%. The model also performed strongly for chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning enabled prediction of one-year major adverse cardiovascular events with AUROC 0.79 and estimation of left ventricular ejection fraction with mean absolute error 7.3%. Embeddings also captured disease progression across serial examinations. With a mean inference time of 4.2 seconds in hospital deployment, DeepCORO-CLIP provides a foundation for automated coronary angiography interpretation at the point of care. Code, sample data, model weights, and deployment infrastructure are publicly released.
Mar 19, 2026

ARIADNE: A Perception-Reasoning Synergy Framework for Trustworthy Coronary Angiography Analysis

Conventional pixel-wise loss functions fail to enforce topological constraints in coronary vessel segmentation, producing fragmented vascular trees despite high pixel-level accuracy. We present ARIADNE, a two-stage framework coupling preference-aligned perception with RL-based diagnostic reasoning for topologically coherent stenosis detection. The perception module employs DPO to fine-tune the Sa2VA vision-language foundation model using Betti number constraints as preference signals, aligning the policy toward geometrically complete vessel structures rather than pixel-wise overlap metrics. The reasoning module formulates stenosis localization as a Markov Decision Process with an explicit rejection mechanism that autonomously defers ambiguous anatomical candidates such as bifurcations and vessel crossings, shifting from coverage maximization to reliability optimization. On 1,400 clinical angiograms, ARIADNE achieves state-of-the-art centerline Dice of 0.838, reduces false positives by 41% compared to geometric baselines. External validation on multi-center benchmarks ARCADE and XCAD confirms generalization across acquisition protocols. This represents the first application of DPO for topological alignment in medical imaging, demonstrating that preference-based learning over structural constraints mitigates topological violations while maintaining diagnostic sensitivity in interventional cardiology workflows.
Jul 24, 2026

CARDIAG: A Dense Segment Classification Benchmark of Deep Learning Architectures for Coronary Angiography

Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols. In this work we demonstrate a new benchmark for the assessment of deep learning models which densely classify pixels of coronary angiograms to one of SYNTAX classes (or background). The evaluation covers 24 distinct architectures starting with classic convnets to recent state-space-based vision algorithms. We release CARDIAG - a multi-center, multi-label dataset which we carefully split to reliably compute metrics, accounting for diameter error, overlap, centerline quality and calibration. The data contains SYNTAX labels, binary, uncertainty and segmentation masks as well as intermediate frames together with the selected non-sensitive DICOM metadata. From the multitude of algorithms, we nominate ConvNeXt V2 encoder with DeepLab V3 Plus decoder as the best performing, achieving macro F1=0.456F_1=0.456, which we then ensemble with Mamba U-Net and Feature Pyramid Network, for an increased F1=0.479F_1=0.479. We demonstrate all the architectures to be well calibrated and determine the generalization of the top 5 methods, together with the data efficiency of these architectures. We highlight the importance of both high-resolution and low-resolution features in encoding. We also demonstrate the model correctness in the context of patient demographic, vessel sides and projection angle configurations. Overall the released benchmark allows for future studies to robustly and rigorously assess the proposals, not only for SYNTAX segmentation, but lesion detection and many more.