SynthRCT: Scalable Conditional Deformation Synthesis for Synthetic Repeat CT Generation

Authors: Tomas Guija-ValienteBlanca Rodriguez-GonzalezNorberto Malpica

Organizations: Medical Image Analysis and Biometry Lab, Universidad Rey Juan Carlos, Madrid, Spain

Abstract

In proton therapy, plans are typically optimized on a single planning CT, making robustness evaluation essential under anatomical changes. However, current scenarios often rely on simplified perturbations that poorly capture complex, patient-specific variability. We propose SynthRCT, a scalable conditional generative framework for 3D anatomical deformation synthesis. Based on a conditional variational autoencoder, SynthRCT learns a latent deformation space and decodes sampled latent codes into local stationary velocity fields conditioned on an input anatomy. Local fields are assembled into coherent full-volume transformations, enabling memory-scalable generation for large field-of-view CT data. We validate the approach on respiratory 4DCT data with multiple breathing-phase anatomies per subject. SynthRCT enables patient-specific sampling of plausible anatomical transformations beyond predefined robustness scenarios. Code available at: https://github.com/TomasGuija/SynthRCT.

Explore similar work

Jul 3, 2026cs.CV

CONFLUX: A Latent Diffusion Model for 3D Chest-CT Synthesis with RL Post-Training

Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning. We present CONFLUX, a latent diffusion model for chest computed tomography (CT): a 3D variational autoencoder compresses each volume, and a rectified-flow transformer generates in the latent space. Generation is conditioned on structured radiological metadata (18 abnormality findings, sex, age, and reconstruction kernel) through adaptive layer normalization. The model leads strong volumetric baselines on tri-planar Frechet distance (FID 32.3 vs. 74.6 for MAISI) while exposing direct control over clinical attributes. To strengthen that control we add an online reinforcement-learning post-training stage (group-relative policy optimization) that rewards how reliably a classifier recovers the requested findings from each generated volume. Judged by a separate, independent classifier, post-training removes 47% of the shortfall relative to real-scan reliability. We release the model and a ~200k synthetic chest-CT dataset with conditioning metadata spanning a wide variety of clinical findings.
Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge +1
May 13, 2026physics.med-ph

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8±21.364.8\pm21.3 HU, PSNR \sim30 dB, MS-SSIM \sim0.936, Dice 0.79, photon γ2%/2mm>98%γ_{2\%/2\text{mm}}>98\%, proton γ85%γ\approx85\%. Task 2 improved: MAE 48.3±13.448.3\pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%γ>99\%, proton γ89%γ\approx89\%. Strong image--segmentation correlations (ρ=0.78ρ=0.78--0.790.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Viktor Rogowski, Maarten L. Terpstra, Niklas Wahl +30
May 19, 2026cs.CV

EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis

Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows. The open source code for EPC-3D-Diff is available at https://github.com/ALZAHRAALTALIB/EPC-3D-Diff.
Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat +3