eess.SPSep 9, 2026

Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

Authors: Ian C. GuzmánRadu BabiceanuBerker Peköz

Abstract

More Electric Aircraft require fast and reliable monitoring of high-frequency electrical networks, yet most power quality disturbance and fault diagnosis methods are developed for conventional 50 or 60 Hz grids. This work presents a hardware-aware deep learning framework for multiclass detection of electrical faults and power quality disturbances in a 400 Hz aerospace power system. A high-fidelity simulation model inspired by the Boeing 787 electrical architecture generates voltage and current waveforms for 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two datasets, each containing 73,500 samples, are formed from one-dimensional time-series signals and short-time Fourier transform time-frequency representations. Signal-processing augmentation, domain randomization, and class-specific generative adversarial networks increase waveform diversity, and the time-series dataset is released through IEEE DataPort. We compare 1D and 2D convolutional neural networks, long short-term memory networks, CNN-LSTM hybrids, ResNet, MobileNet, and VGG models under common training conditions. A compact ResNet provides the best accuracy-complexity tradeoff, achieving 96.94 percent software test accuracy with 175,685 parameters. After 8-bit quantization and deployment on a Xilinx Zynq UltraScale Plus MPSoC ZCU102, the model achieves 95.87 percent accuracy and a measured mean neural-network accelerator latency of 6.90 ms per input record. The results establish simulation-based, accelerator-level feasibility for embedded edge AI in aircraft electrical health monitoring and motivate future end-to-end data acquisition and experimental validation.

Explore similar work

May 17, 2026eess.SY

Latency-Aware Deep Learning Benchmark for Real-Time Cyber-Physical Attack and Fault Classification in Inverter-Dominated Power Grids

This work introduces a latency-aware benchmarking framework for evaluating deep learning models in power system anomaly detection using high-fidelity, time-domain signals generated from an industry-grade electromagnetic transient simulator. Eight neural network architectures, ranging from MLPs to Transformers, were systematically evaluated on streaming datasets representing both physical faults and cyber-attacks in inverter-dominated networks. All models successfully classified two representative multi-event sequences in real time with sub-cycle response times below 15 ms. However, although classification decisions occurred within one cycle, the end-to-end inference latency consistently exceeded three cycles, ranging from 50 to 90 ms. These results highlight a critical gap between algorithmic capability and protection-grade deployment, pointing to the need for further optimization and hardware acceleration. The findings establish a reproducible benchmark for sub-cycle anomaly detection and provide guidance for transitioning machine learning methods from research prototypes to real-world protection applications.
Emad Abukhousa, Saman Zonouz, A. P. Sakis Meliopoulos
May 21, 2026cs.CR

Characterizing the Fault Response of the Intel Neural Compute Stick 2 Under Single-Pulse Electromagnetic Fault Injection

Vision processing units and other commercial neural-network inference accelerators are increasingly deployed in safety-relevant edge applications, but their fault response under transient hardware disturbances remains poorly characterized in the open literature. For the Intel Movidius Myriad X, packaged as the Intel Neural Compute Stick 2 (NCS2), only a single feasibility study has been published. We report a systematic single-pulse electromagnetic fault injection (EMFI) campaign on the NCS2 running three ImageNet-trained convolutional neural networks (ResNet-18, ResNet-50, VGG-11) on the OpenVINO runtime. Across 1,536 spot-test trials at characterized hotspots and approximately 16,000 parameter-search trials, single pulses produce four reproducible outcome classes: no measured accuracy change, minor silent data corruption, major persistent degradation that survives across subsequent inferences until model reload, and device hangs requiring USB power-cycling; these outcomes are respectively interpreted as no-effect, SDC with possible SET-like or small persistent-state mechanisms, SEU-like persistent corruption, and SEFI-like loss of functionality. Two findings are central. First, the major-degradation class can be induced at 18-31% of trials at characterized hotspots, with post-collapse top-1 accuracy below five percent and persistence across all subsequent inferences until explicit model reload - a regime that no inference-API-level mechanism detects. Second, this regime is also inducible by pulses delivered to an idle device with the model already loaded, demonstrating that load-time integrity checks alone are insufficient. We discuss mitigation strategies graded by class, focusing on mechanisms implementable at the application level without modification to the device firmware or the OpenVINO runtime.
Štefan Kučerák, Jakub Breier, Xiaolu Hou
Jun 23, 2026cs.LG

Lightweight Transformer Models for On-Device Fault Detection: A Benchmark Study on Resource-Constrained Deployment

On-device fault detection enables real-time diagnostics without cloud dependency, but deploying machine learning models on resource-constrained hardware demands careful tradeoffs between accuracy, latency, and model size. We present a benchmark comparing traditional ML methods (Random Forest, XGBoost, SVM, Logistic Regression) against lightweight transformer architectures (DistilBERT, TinyBERT-6L, TinyBERT-4L, MobileBERT) for binary fault detection across three public datasets: NASA C-MAPSS turbofan degradation, SECOM semiconductor manufacturing, and UCI AI4I 2020 predictive maintenance. We evaluate classification performance (F1-score, AUC), model size, and CPU inference latency, and further assess INT8 dynamic quantization and a two-stage adaptive inference pipeline. Our results reveal that on well-separated sensor data (C-MAPSS), lightweight transformers match traditional ML at 87.8% F1 but at 100x the model size and 9000x the latency. TinyBERT-4L emerges as the most deployment-friendly transformer at 55 MB and 18 ms CPU latency. INT8 quantization reduces size by 25% while preserving 86.9% F1. Our adaptive pipeline, routing 97.9% of predictions through a quantized triage model and only 2.1% to a larger expert, achieves 87.6% F1 at 19.5 ms average latency. On severely imbalanced datasets (SECOM, UCI-PM), both traditional and transformer methods struggle significantly, highlighting fundamental limitations of current approaches for extreme class imbalance in fault detection. All code is publicly available.
Disha Patel