cs.CLSep 2, 2026

Clinical Reasoning Under a Partially Observed Objective in Cone Beam CT Report Generation

Authors: Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan

Organizations: DiceMed, Cuttack, Odisha, India · University of Maryland, College Park, Maryland, USA · Indira Gandhi National Open University, New Delhi, India · Indian Institute of Technology Jammu, India

Abstract

Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large language model judgement of factual entailment and 20% on lexical overlap, of which only the lexical fifth is visible during development. The grader's BLEU-4 and METEOR routines are reproduced in pure Python and match the reference to machine precision, and an offline entailment surrogate, which tells a report written for one patient from one written for another at an area under the curve of 0.987, makes the composite objective cheap enough to optimise directly. Over the 622-case public release, a report selected against the visible lexical ranking scores 0.2909, whereas one selected against the composite objective scores 0.4122, because pursuing n-gram overlap drives entailment precision from 0.522 down to 0.266. A 29 million parameter encoder fine-tuned on the release reaches a prevalence-weighted out-of-fold area under the curve of 0.486 over 985 statements, indistinguishable from the corpus prior, while nine numbers read from the image header reach 0.945 for mandible coverage and 0.872 for condyle coverage, and acquisition centre alone predicts sentence choice at 0.718 against 0.663 for the image-derived model, identifying dictation convention rather than anatomy as the quantity the lexical metrics reward. The delivered system emits eight unconditional statements and five gated on header geometry under polarity, laterality and tooth-level consistency constraints, and reaches METEOR 0.3542 over 50 held-out cases from an unseen centre. The dataset and code are available at https://github.com/GIND123/CBCT-Clinical-Reasoner

Figures & tables

Explore similar work

Oct 1, 2026cs.CV

EviDent-CBCT: Evidence-Bottlenecked Report Generation from Dental CBCT under Non-Exhaustive Report Supervision

Dento-maxillofacial cone-beam CT (CBCT) reports may contain dozens of tooth-specific, anatomical, and spatial findings from a single 3D scan. Learning to generate such reports from limited clinical data is challenging because routine reports may not exhaustively document image findings, and a non-mention may reflect either absence or non-reporting. We present EviDent-CBCT, an evidence-bottlenecked framework designed for this incomplete supervision. An anatomy-aware network maps each CBCT scan to a discrete record of tooth-level, global, and tooth-IAC evidence. A dental-logic consistency projection reconciles incompatible evidence before a deterministic renderer and an image-blind local language model generate the report using only this record. For tooth-level evidence, reliability-aware training uses eligible non-mentions as reduced-weight negatives, while unreported global and tooth-IAC labels remain unknown. A metal-sensitive input channel preserves intensity cues from dental materials. Across three validation runs, EviDent-CBCT achieves 0.666±0.0060.666\pm0.006 merged evidence set-F1 and 0.402±0.0030.402\pm0.003 RadFact-Lite-Dental logical-F1, versus 0.371±0.0180.371\pm0.018 for the strongest controlled direct baseline. In the ODIN 2026 challenge, it ranked second in automated evaluation and third in blinded clinical Arena comparison on the hidden test set. These results support the discrete evidence record as an effective and auditable interface for CBCT report generation.
Sep 1, 2026cs.CV

A multicenter benchmark and clinically structured metric for coronary CTA report generation

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSMCCTA_{\text{CCTA}}, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSMCCTA_{\text{CCTA}} showed a strong correlation with radiologist scores (Pearson's r=0.97r=0.97, p<0.001p<0.001), exceeding the next-best metric, FORTE (r=0.70r=0.70), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9%). Under controlled perturbations, CSMCCTA_{\text{CCTA}} remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSMCCTA_{\text{CCTA}} scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSMCCTA_{\text{CCTA}} enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.
Apr 27, 2026cs.AI

CT-FineBench: A Diagnostic Fidelity Benchmark for Fine-Grained Evaluation of CT Report Generation

The evaluation of generated reports remains a critical challenge in Computed Tomography (CT) report generation, due to the large volume of text, the diversity and complexity of findings, and the presence of fine-grained, disease-oriented attributes. Conventional evaluation metrics offer only coarse measures of lexical overlap or entity matching and fail to reflect the granular diagnostic accuracy required for clinical use. To address this gap, we propose CT-FineBench, a benchmark built from CT-RATE and Merlin to evaluate the fine-grained factual consistency of CT reports, constructed from CT-RATE and Merlin. Our benchmark is constructed through a meticulous, Question-Answering (QA) based process: first, we identify and structure key, finding-specific clinical attributes (like location, size, margin). Second, we systematically transform these attributes into a QA dataset, where questions probe for specific clinical details grounded in gold-standard reports. The evaluation protocol for CT-FineBench involves using this QA dataset to query a machine-generated report and scoring the correctness of the answers. This allows for a comprehensive, interpretable, and clinically-relevant assessment, moving beyond superficial lexical overlap to pinpoint specific clinical errors. Experiments show that CT-FineBench correlates better with expert clinical assessment and is substantially more sensitive to fine-grained factual errors than prior metrics.