Abstract

Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large language model judgement of factual entailment and 20% on lexical overlap, of which only the lexical fifth is visible during development. The grader's BLEU-4 and METEOR routines are reproduced in pure Python and match the reference to machine precision, and an offline entailment surrogate, which tells a report written for one patient from one written for another at an area under the curve of 0.987, makes the composite objective cheap enough to optimise directly. Over the 622-case public release, a report selected against the visible lexical ranking scores 0.2909, whereas one selected against the composite objective scores 0.4122, because pursuing n-gram overlap drives entailment precision from 0.522 down to 0.266. A 29 million parameter encoder fine-tuned on the release reaches a prevalence-weighted out-of-fold area under the curve of 0.486 over 985 statements, indistinguishable from the corpus prior, while nine numbers read from the image header reach 0.945 for mandible coverage and 0.872 for condyle coverage, and acquisition centre alone predicts sentence choice at 0.718 against 0.663 for the image-derived model, identifying dictation convention rather than anatomy as the quantity the lexical metrics reward. The delivered system emits eight unconditional statements and five gated on header geometry under polarity, laterality and tooth-level consistency constraints, and reaches METEOR 0.3542 over 50 held-out cases from an unseen centre. The dataset and code are available at https://github.com/GIND123/CBCT-Clinical-Reasoner

Figures & tables

Explore similar work

CardsList
  1. A multicenter benchmark and clinically structured metric for coronary CTA report generation

    Sep 1, 2026Zhiyu Ye, Yue Sun, Limiao Zou +7VLM EvaluationRadiology Report Generation

  2. CT-FineBench: A Diagnostic Fidelity Benchmark for Fine-Grained Evaluation of CT Report Generation

    Apr 27, 2026Ruifeng Yuan, Wanxing Chang, Weiwei Cao +4Radiology Report GenerationMedical Report Generation