eess.IVSep 11, 2026

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Authors: Benjamin Jin, Maria del C. Valdés Hernández, Richard Bortsov, Joanna M. Wardlaw, Daniel Bos, Grant Mair

Organizations: Institute for Neuroscience and Cardiovascular Research, University of Edinburgh, United Kingdom · Department of Epidemiology, Erasmus MC, The Netherlands · UK Dementia Research Institute, University of Edinburgh, United Kingdom · Department of Radiology and Nuclear Medicine, Erasmus MC, The Netherlands · Department of Clinical Neurosciences, NHS Lothian, United Kingdom

Abstract

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean ±\pm SD) of up to 71.5 ±\pm 3.7 for a single artery and 59.8 ±\pm 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

Figures & tables

Explore similar work

Jul 10, 2025

ArteryX: A Reliable End-to-End Toolbox for Standardized Intracranial Artery Feature Extraction from 3D TOF-MRA

Cerebrovascular research heavily relies on quantitative analysis of intracranial arteries from time-of-flight magnetic resonance angiography, yet existing processing pipelines remain limited by inconsistent artery labeling and a high manual correction burden. We present ArteryX, a toolbox for extracting features that standardizes artery classification across proximal and distal vascular territories. It integrates segmentation handling, isotropic processing, vessel-fused graph construction, and constrained landmark-based classification within a unified artery-specific feature reporting and reproducible workflow. The toolbox extracts morphological, topological, and complexity features including total length, mean radius, volume, surface area, branch count, tortuosity, and fractal dimensionality for standardized artery-segments. Test-and-validation were performed using three complementary datasets: (1)TopBrain-Challenge benchmarking with annotated arteries, (2)synthetic known-reference validation, and (3)exploratory in-vivo cohort of cerebral small vessel disease. In TopBrain analyses, ArteryX with supervised nnUnet segmentation showed minimal bias, while iCafe showed the highest bias and a large limit-of-agreement. ArteryX consistently demonstrated robust downstream quantification performance across segmentation sources (unsupervised/supervised). Agreement analyses showed minimal bias for radius and good sensitivity of extent-dependent metrics throughout the noisier segmentations compared to the state-of-the-art iCafe-toolbox. Furthermore, a stage-wise human-in-the-loop protocol showed lower intervention time than iCafe. In an in-vivo-cohort (48CSVD+, 20CSVD-), ArteryX-derived distal and territory-level features showed group-level differences, not evident with iCafe. To facilitate adoption-and-reproducibility, ArteryX is designed with versioned builds, tutorials, and documentation.
Jul 6, 2026

Shape Over Intensity: Directional Topological Encoding for False Positive Reduction in Intracranial Aneurysm Detection

Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates. Convolutional neural networks (CNNs) rely on local pixel intensities, causing systematic confusion between saccular aneurysms and vascular bifurcations - a problem especially acute for small lesions (<3 mm), where detection sensitivity falls below 60%. We propose a plug-and-play, topology-aware false-positive reduction framework evaluating the Smooth Euler Characteristic Transform (SECT) - a directional representation encoding global 3D vascular geometry independently of intensity - against persistence-based summaries (Persistence Images and Landscapes), tested on a stratified subset of the RSNA 2025 dataset. SECT achieves an AUC of 0.943, substantially outperforming direction-agnostic methods (AUC ~0.68), and exhibits a clinical performance inversion: it excels on the sub-3 mm cohort, maintaining 0.943 AUC and 78.5% sensitivity at 95% specificity. The representation is also scanner-agnostic, achieving 0.927 mean AUC under leave-one-scanner-out (LOGO) validation across four manufacturers. By capturing asymmetric geometric invariants rather than intensity profiles, SECT reliably resolves the primary structural confounder in IA detection, positioning it as a robust downstream filter for hybrid deep-learning diagnostic pipelines.
Mar 11, 2026

DINOv3 with Test-Time Calibration for Automated Carotid Intima-Media Thickness Measurement on CUBS v1

Carotid intima-media thickness (CIMT) measured from B-mode ultrasound is an established vascular biomarker for atherosclerosis and cardiovascular risk stratification. Although a wide range of computerized methods have been proposed for carotid boundary delineation and CIMT estimation, robust and transferable deep models that jointly address segmentation and measurement remain underexplored, particularly in the era of vision foundation models. Motivated by recent advances in adapting DINOv3 to medical segmentation and exploiting DINOv3 in test-time optimization pipelines, we investigate a DINOv3-based framework for carotid intima-media complex segmentation and subsequent CIMT measurement on the Carotid Ultrasound Boundary Study (CUBS) v1 dataset. Our pipeline predicts the intima-media band at a fixed image resolution, extracts upper and lower boundaries column-wise, corrects for image resizing using the per-image calibration factor provided by CUBS, and reports CIMT in physical units. Across three patient-level test splits, our method achieved a mean test Dice of 0.7739 ±\pm 0.0037 and IoU of 0.6384 ±\pm 0.0044. The mean CIMT absolute error was 181.16 ±\pm 11.57 μμm, with a mean Pearson correlation of 0.480 ±\pm 0.259. In a held-out validation subset (n=28n=28), test-time threshold calibration reduced the mean absolute CIMT error from 141.0 μμm at the default threshold to 101.1 μμm at the measurement-optimized threshold, while simultaneously reducing systematic bias toward zero. Relative to the error ranges reported in the original CUBS benchmark for classical computerized methods, these results place a DINOv3-based approach within the clinically relevant ∼\sim0.1 mm measurement regime. Together, our findings support the feasibility of using vision foundation models for interpretable, calibration-aware CIMT measurement.