eess.IVSep 18, 2026

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

Authors: Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan, Kristen W Yeom, Qiyong Gong, Nan-Jie Gong

Organizations: Shanghai Key Laboratory of Magnetic Resonance, School of Physics, East China Normal University, Shanghai 200041, China · Institute of Magnetic Resonance and Molecular Imaging in Medicine, East China Normal University, Shanghai 200062, China · Department of Radiology, Affiliated Hospital of Guizhou Medical University, Guiyang, China · Department of Radiology and Huaxi MR Research Center (HMRRC), Institution of Radiology and Medical Imaging, West China Hospital, Sichuan University, Chengdu, China · Research Unit of Psychoradiology, Chinese Academy of Medical Sciences, Chengdu, China · RadioDynamic Medical, Shanghai 200031, China · Department of Radiology, Lucile Packard Children’s Hospital, Stanford, California 94304, USA · Department of Radiology, West China Xiamen Hospital of Sichuan University, Xiamen, China

Abstract

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

Figures & tables

Explore similar work

Oct 2, 2026

Learning Subject-Specific Anatomical Representations via Manifold Expansion: Application to Accelerated Multi-Contrast MRI

Clinical MRI routinely acquires multiple contrast-weighted images of the same anatomy for complementary tissue characterization. However, current accelerated MRI methods typically reconstruct each contrast independently, without fully exploiting shared anatomical information. This work aims to learn anatomical representations invariant to contrast-dependent appearance for reconstruction of accelerated multi-contrast MRI. We propose MAX (MAnifold eXpansion), a subject-specific framework that learns anatomical representations from a single fully sampled reference contrast. To address the under-constrained separation of shared anatomy and contrast-dependent components from a single image, MAX expands the multi-contrast manifold using anatomy-preserving intensity augmentations. A disentangled implicit neural representation models augmented samples using shared spatial coordinates for anatomy and spatially invariant coordinates for contrast appearance. The learned anatomical representation is then fixed, with the contrast representation adapted to the undersampled target data, followed by unrolled refinement. Theoretical analyses further provide insight into the disentangled representation learning and explain how the learned anatomical representation improves the target contrast reconstruction. At R = 8 for brain MRI and R = 6 for knee MRI, MAX achieves the highest mean PSNR and SSIM across all tasks, improving PSNR by more than 1 dB over the strongest baseline for both brain contrasts. MAX more faithfully recovers subtle anatomical and pathological structures and remains robust to inter-contrast motion, structural heterogeneity between reference and target contrasts, and measurement noise. Therefore, MAX provides a general strategy for leveraging high-quality reference scans in accelerated MRI and has the potential to be extended to other reference-assisted MRI inverse problems.
Jul 2, 2026

Self-Auditing Residual Drifting for Pathology-Preserving Accelerated Knee MRI

Accelerated magnetic resonance imaging reduces acquisition time, but reconstruction from undersampled k-space can blur diagnostically relevant structures or introduce failures that are not captured by global image metrics. We propose SA-RDM-DC, a Self-Auditing Residual generative Drifting Model with Data Consistency for accelerated knee MRI. The method adapts the newly proposed generative drifting paradigm to accelerated MRI by training a physics-conditioned drift field from the zero-filled reconstruction toward the fully sampled residual correction. It predicts image- and missing-k-space residual corrections, enforces data consistency with acquired k-space, uses frequency-aware and residual drifting supervision to recover fine detail, and produces dense error maps and slice-level risk scores in the same inference pass. We evaluate SA-RDM-DC on multi-coil fastMRI knee data at acceleration factors of 4, 8, and 12, with fastMRI+ pathology annotations for region-level and classifier-based task preservation, and on SKM-TEA for zero-shot and fine-tuned protocol-shift evaluation. Compared with zero-filled reconstruction, UNet-image-SENSE, DC-UNet, Score-Diffusion, ELF-Diff, SENSE-VarNet, and MoDL baselines, SA-RDM-DC achieves the highest SSIM across fastMRI acceleration factors while retaining subsecond per-slice inference and avoiding the long sampling time of iterative diffusion baselines. In pathology-aware analysis, SA-RDM-DC preserves lesion-region structural fidelity and reduces meniscus prediction instability. Its self-auditing scores strongly identify high-error reconstructions on fastMRI and partially transfer as a selective-review signal under SKM-TEA protocol shift. These results support reconstruction evaluation that jointly considers image fidelity, pathology preservation, runtime, and case-specific reliability.
Sep 3, 2026

Sharpening the Ensemble: An SSIM-Aligned Residual Refiner for Brain-MRI Inpainting Post-Processing

Brain-MRI inpainting replaces a masked region of a scan with synthesized, anatomically plausible healthy tissue, so that analysis tools built for healthy brains can be applied to images they would otherwise reject. On the BraTS local-synthesis benchmark, which ranks submissions on the structural similarity index (SSIM), the peak signal-to-noise ratio, and the mean squared error (MSE) jointly, the strongest recent models are accurate, but several report blurry synthesized regions and attribute this to the mean-seeking behavior of the ℓ1\ell_1 and MSE terms in their training losses. We address this in post-processing, forming a deep ensemble of the two co-first-place 2025 models and training a lightweight residual refiner on the ensemble's own outputs under an ℓ1\ell_1 loss augmented with a structural-similarity term whose weight λλ we vary. At a moderate λλ the refiner improves SSIM over the ensemble, from 0.87670.8767 to 0.87800.8780 on a held-out reproduction of the official scorer and from 0.85550.8555 to 0.85720.8572 on the official validation leaderboard, with essentially no change in MSE. The gain is small but consistent, improving 62.6%62.6\% of the held-out cases with a signed-rank p=2.2×10−7p=2.2\times10^{-7}, whereas over-weighting the structural term reverses it. Two ablations bound the effect. Adding any third model to the two-model ensemble degrades it, and classical unsharp masking fails to improve SSIM at any strength (best 0.87650.8765 against 0.87670.8767), so the gain reflects learned rather than indiscriminate sharpening. The result is a cheap, reproducible post-processing stage that improves an already strong ensemble without any large-scale retraining.