cs.CVSep 22, 2026

Lessons learned from deploying imaging AI with the open PACS-AI platform

Authors: Samuel Kadoury, Julie G. Hussin, Pascal Thériault-Lauzier, Laurent Létourneau-Guillon, Rob Lewis, Adam McArthur, Gordon J. Harris, Houda Bahig, +6 more

Abstract

We describe deploying imaging AI at six hospitals through PACS-AI, an open self-hosted platform. The binding constraint is not model accuracy but infrastructure to route studies, display results, capture feedback, and audit what runs. At one center, angiography models completed 515 of 607 jobs (84.8%); failures reflected absent diagnostic views, and 78.1% of 638 clinician ratings were positive. Publishing honest readiness levels for every model is itself a governance practice.

Explore similar work

CardsList
  1. When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

    Aug 10, 2026Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez +9Chest X-RayMedical Imaging Datasets