cs.CVSep 15, 2026

One Evaluation, Any Operating Point: Hypernetwork-Amortized MeanFlow for 3D MRI Reconstruction

Authors: Ruibo Wang

Organizations: Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, 2600 AA Delft, Netherlands

Abstract

Generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment: tens of network evaluations per volume, and protocol-specific hyperparameter tuning. A third hidden cost is the scanner's fixed sampling pattern. We treat the whole operating point as an input. A 3D MeanFlow patch network (a one-step flow model) is fine-tuned end-to-end through a warm-started, five-iteration differentiable conjugate-gradient projection. A small hypernetwork maps the operating point (data-consistency weight, acceleration, and the Cartesian sampling pattern itself) to the network's per-channel modulation. Three findings follow. (i) Learning the acquisition is worth more than any other operating point: on clinical knee data, the learned mask gains up to +2.34 dB over the protocol's variable-density mask. This gain requires the solver: with a feed-forward reconstructor the same learned mask hurts at 4x (-1.7 dB), but with the data-consistency projection it adds +4.6 dB. (ii) One evaluation is highly effective: it beats a 20-step patch-diffusion prior by up to +3.1 dB on brain and +2.9 dB on knee. Three to five evaluations extend the front to +6 dB while using a quarter of the prior's network calls. (iii) Fully sampled targets are optional: trained self-supervised on a split of acquired samples, the reconstructor matches its supervised twin at 4x on real data. Finally, we report what failed and why: subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight.

Figures & tables

Appendix figures & tables16 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 26, 2026

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors (10×10\times to 50×50\times). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.
Mar 4, 2026

MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI Reconstruction

Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness. In many clinical workflows, complementary MRI acquisitions (e.g. high-quality structural scans) are routinely available, yet existing reconstruction methods lack mechanisms to leverage this additional information. We propose MPFlow, a zero-shot multi-modal reconstruction framework built on rectified flow that incorporates auxiliary MRI modalities at inference time without retraining the generative prior to improve anatomical fidelity. Cross-modal guidance is enabled by our proposed self-supervised pretraining strategy, Patch-level Multi-modal MR Image Pretraining (PAMRI), which learns shared representations across modalities. Sampling is jointly guided by data consistency and cross-modal feature alignment using pre-trained PAMRI, systematically suppressing intrinsic and extrinsic hallucinations. Extensive experiments on HCP and BraTS show that MPFlow matches diffusion baselines on image quality using only 20% of sampling steps while reducing tumor hallucinations by more than 15% (segmentation dice score). This demonstrates that cross-modal guidance enables more reliable and efficient zero-shot MRI reconstruction.
Sep 29, 2026

Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction

4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the phase difference between velocity encodings, not by image magnitude. Recent work has developed a per-encoding variational network to address image reconstruction in this field. In this work, we incorporate a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision. At the same time, we add multiple acquisition-robust and conditioning strategies based on the acceleration factors. On the CMRx4DFlow~2026 aortic dataset (1.5 and 3T), our model lowers RelErr by 3838--50%50\% and AngErr by 7.07.0--8.7∘8.7^\circ against a training-matched baseline across R=10R{=}10--5050, improving on every held-out subject at every acceleration. Our model also shows strong generalization ability to transfer on out-of-distribution data by employing the joint training scheme, with an increase of 7.2%7.2\% in SSIM and decrease of 38%38\% and 31%31\% in AngErr and RelErr respectively.