cs.CVSep 27, 2026

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

Authors: Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera

Organizations: Faculty of Engineering, University of Peradeniya, Sri Lanka · School of Computing Technologies, RMIT University, Melbourne, Australia · School of Engineering & Digital Technologies, University of Southern Queensland, Brisbane, Australia · School of Engineering & Technologies, UNSW, Canberra, Australia

Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD2^2 at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their kk-nearest-neighbor radius at 33% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman ρ=1.00ρ= 1.00), and a subject-disjoint real set yielded MMD2=0\mathrm{MMD}^2 = 0 (permutation p=1p = 1). An unconditional denoising diffusion probabilistic model achieved MMD2=0.073\mathrm{MMD}^2 = 0.073 (95% confidence interval [0.071,0.080][0.071, 0.080]) but covered only 38% of the real distribution. Under progressive mode dropping, kk-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically (ρ=−1.00ρ= -1.00). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

Figures & tables

Explore similar work

Oct 29, 2025eess.IV

MedForj: An open, large-scale foundational generative prior for high-resolution 3D brain MRI

This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on 72,65972{,}659 1~mm isotropic 3D T1T_1-weighted MRI human brain image volumes from 38,17438{,}174 subjects, drawn from a curated corpus of 80,67580{,}675 volumes from 42,50642{,}506 subjects spanning 3838 publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at 28.8028.80~dB PSNR and 0.8740.874 SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at 72.6%72.6\%, and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at https://github.com/piksl-research/medforj.
Aug 7, 2026cs.CV

Tokenizer-Generator Coupling in Medical Image Generation

Latent medical image generators usually treat the tokenizer as fixed preprocessing. We test whether this separation holds in a controlled ChestMNIST study at 64×6464\times64 that crosses discrete tokenizers, generator families, and sampler settings under a shared latent grid, with continuous-latent reference cells. The rankings depend jointly on the tokenizer, generator, and sampler. The best quantizer changes with the generator, and validation-based sampler selection changes the apparent generator ranking. We interpret this through a rate-distortion-modelability framing in which modelability is conditional on the generator, sampler, and inference budget. The interaction persists when the vocabulary-1024 block is retrained at three seeds, with 4 of 9 pairwise quantizer comparisons exceeding three seed standard deviations, including a reversal between LFQ and FSQ from MaskGIT to D3PM; the rest of the grid was trained at a single seed and is correspondingly less certain. Reconstruction PSNR alone is not a reliable selection criterion. On LFQ-1024, retuning the D3PM and SEDD samplers on a held-out validation split reduces FID-192 from 0.44/0.41 at the default budget to 0.09/0.10 at lower NFE, replicated across seeds, although the continuous references were not given an equivalent sampler sweep. FID-192, our internal ranking metric, ranks consistently with standard FID-2048 (Spearman 0.89) and with a label-free classifier two-sample test (0.86). All experiments are unconditional, use low-resolution 64×6464\times64 medical-style images and are evaluated with non-clinical FID-based metrics, and our claims are limited to that setting. Implementations are released at https://github.com/liamchalcroft/medtokenizers and https://github.com/liamchalcroft/medlatents.
Jun 17, 2026cs.CV

Scaling Generative Foundation Models for Chest Radiography with Rectified Flow Transformers

We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale. Existing radiographic AI models often suffer from poor generalisation across patient subpopulations, institutions, and acquisition settings, resulting in limited real-world clinical utility. Controlled, high-fidelity synthesis of chest radiographs is a promising path toward diversifying clinical datasets and evaluating the robustness of diagnostic models. Therefore, we present the largest specialist generative foundation model for chest radiographs to date, with over 1.3B parameters, trained for 1.6T tokens on a curated, heterogeneous dataset comprising 1.2M radiographs and clinical expert-guided metadata. Our model supports controllable radiograph generation and editing across multiple demographic subgroups, acquisition views, and a dozen pathologies. Moreover, we significantly advance the state of the art in radiograph synthesis fidelity, producing images that are indistinguishable from real radiographs to clinical experts.