EgoHumanoid-V2: Human-to-Humanoid Transfer of Coordinated Whole-Body Skills for Loco-Manipulation
Organizations: OpenDriveLab at The University of Hong Kong · Alibaba Group · Shanghai Innovation Institute · Fudan University · Beihang University · Sichuan University · Archon Robotics
Abstract
Human demonstrations capture diverse scenes and rich whole-body skills without requiring robot teleoperation. Prior work on egocentric transfer has emphasized scene generalization in loco-manipulation under decoupled control, leaving direct transfer of coordinated whole-body skills less explored. We present EgoHumanoid-V2, the first egocentric human-to-humanoid skill transfer framework for coordinated whole-body loco-manipulation. At its core, coarse-to-fine action alignment combines kinematic reference correction with dynamics-aware refinement. It improves end-effector pose accuracy while preserving whole-body coordination. We also use robot-arm rendering and training-time image augmentation to reduce the visual embodiment gap and improve viewpoint robustness. On four real-world tasks, vision-language-action (VLA) policies trained on aligned human data show zero-shot skill transfer without target-task robot demonstrations. Task scores are comparable to those of policies trained on teleoperation data at a lower collection cost. These results support human data as direct skill supervision.
Figures & tables
| End-effector Tracking Error ( ) | |||||
|---|---|---|---|---|---|
| Alignment | Close Laptop | Open Fridge | Pull Curtain | Close Drawer | Mean |
| Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) | Pos. (cm) / Ori. ( ∘ ) | |
| 14.08 / 29.43 | 13.27 / 19.37 | 10.31 / 14.86 | 7.17 | 11.21 / 21.22 | |
| 4.22 / 13.84 | 4.24 / 14.72 | 3.13 / 12.74 | 6.22 | 4.45 / 13.77 | |
| 3.04 / 9.50 | 2.76 / 5.77 | 2.02 / 4.85 | 5.80 | 3.41 / 6.71 | |
| Real-World Task Score (%, ) | |||||
| Endpoint Error | Whole-Body Motion Quality | |||||
|---|---|---|---|---|---|---|
| Motion initialization | Pos. (cm) | Ori. ( ∘ ) | Pelvis drop (cm) | Tilt ( ∘ ) | Joint step ( ∘ ) | Extra yaw ( ∘ ) |
| SONIC Rollout | 3.41 | 6.71 | 3.28 | 11.14 | 5.94 | 7.18 |
| Retargeting | 3.42 | 5.32 | 3.30 | 11.87 | 6.51 | 11.45 |
| Whole-Body IK | 3.82 | 6.35 | 5.25 | 12.77 | 7.75 | 23.67 |
| Response | Close Laptop | Open Fridge | Pull Curtain | Close Drawer | Mean |
|---|---|---|---|---|---|
| Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) / Ori. ( ∘ ) | Pos. (cm) | Pos. (cm) / Ori. ( ∘ ) | |
| Unit response | 3.18 / 9.74 | 2.89 / 5.88 | 2.19 / 5.06 | 9.18 | 4.36 / 6.89 |
| MLP response | 3.04 / 9.50 | 2.76 / 5.77 | 2.02 / 4.85 | 5.80 | 3.41 / 6.71 |
| Visual alignment | Task score (%) | Mean | ||||
|---|---|---|---|---|---|---|
| Image augmentation | Robot-arm rendering | Close Laptop | Open Fridge | Pull Curtain | Close Drawer | |
| 31.67 | 16.67 | 35.00 | 50.00 | 33.33 | ||
| 51.67 | 23.33 | 41.67 | — | 38.89 | ||
| 61.67 | 33.33 | 33.33 | 61.67 | 47.50 | ||
| 53.33 | 38.33 | 53.33 | — | 48.33 | ||
Appendix figures & tables12 assets
Supplementary material from the paper’s appendix.
Appendix
| Task | Stage 1 | Stage 2 | Stage 3 |
|---|---|---|---|
| Close Laptop | Right hand reaches a suitable position above the lid. | Right hand makes an effective downward press on the lid. | Lid is fully closed. |
| Open Fridge | Left hand approaches the door gap. | Left hand hooks into the gap. | Refrigerator door opens. |
| Pull Curtain | Right hand grasps the curtain. | Hand pulls the curtain. | Curtain is pulled open by one meter. |
| Close Drawer | Right foot lifts, with the toe in front of the lowest drawer’s outer face. | Right foot pushes the drawer inward. | Drawer is fully closed. |
| Task | SONIC Rollout | Retargeting | Whole-Body IK |
|---|---|---|---|
| Close Laptop | 3.04 / 9.50 | 2.67 / 6.33 | 2.75 / 6.19 |
| Open Fridge | 2.76 / 5.77 | 3.15 / 5.74 | 3.68 / 7.25 |
| Pull Curtain | 2.02 / 4.85 | 2.05 / 3.88 | 2.73 / 5.61 |
| Close Drawer | 5.80 / — | 5.80 / — | 6.11 / — |
| Task | Method | Pelvis drop (cm) | Tilt ( ∘ ) | Joint step ( ∘ ) | Extra yaw ( ∘ ) |
|---|---|---|---|---|---|
| Close Laptop | SONIC Rollout | 0.28 | 9.62 | 2.87 | 3.94 |
| Retargeting | 0.50 | 10.86 | 3.95 | 3.67 | |
| Whole-Body IK | 2.06 | 11.32 | 6.07 | 22.60 | |
| Open Fridge | SONIC Rollout | 3.51 | 10.39 | 7.79 | 7.39 |
| Retargeting | 3.35 | 11.62 | 8.28 | 13.96 | |
| Whole-Body IK | 8.08 | 13.04 | 8.42 | 16.70 |
| Configuration | Time (s/frame) | Pos. (cm) | Ori. ( ∘ ) |
|---|---|---|---|
| 0.65 | 4.86 | 16.46 | |
| 2.55 | 4.77 | 16.51 | |
| 1.27 | 8.40 | 16.40 | |
| 2.11 | 7.16 | 12.36 | |
| 1.80 | 4.04 | 7.90 | |
| 2.33 | 4.11 | 7.94 |
| Stage | Pos. (cm) | Ori. ( ∘ ) |
|---|---|---|
| 17.03 | 36.06 | |
| 5.22 | 21.81 | |
| 3.83 | 10.85 |
| Response | Pos. (cm) | Ori. ( ∘ ) |
|---|---|---|
| Unit response | 4.25 | 9.39 |
| MLP response | 4.10 | 9.21 |
| Variant | Three hand tasks | Foot-operated Close Drawer |
|---|---|---|
| A | IK controls arms and waist; SONIC controls legs. | IK controls both legs; SONIC controls remaining joints. |
| B | Same as A, with SONIC’s balance contribution added. | Same as A, with SONIC’s balance contribution added. |
| C | IK controls arms; SONIC controls waist and legs. | IK controls the right operating leg; SONIC controls remaining joints. |
| Variant | Task | Pos. (cm) | Ori. ( ∘ ) | Tilt ( ∘ ) | Init. falls | Events |
|---|---|---|---|---|---|---|
| A | Close Laptop | 4.45 | 10.43 | 16.97 | 0/5 | 0 |
| Open Fridge | 2.33 | 15.34 | 18.97 | 0/5 | 0 | |
| Pull Curtain | 1.58 | 10.17 | 7.03 | 0/5 | 0 | |
| Close Drawer | — | — | — | 5/5 | — | |
| B | Close Laptop | 2.43 | 8.28 | 13.30 | 0/5 | 0 |
| Open Fridge | 1.55 | 14.45 | 17.26 | 0/5 | 0 |