cs.ROOct 1, 2026

Ex vivo breach detection using electrical conductivity during robotic pedicle drilling in the spine

Authors: Jorge Andrés Pérez Velásquez, François Teyssere, Thibault Chandanson, Quentin Grimal, Brahim Tamadazte

Organizations: ISIR, Sorbonne Université, CNRS UMR 7222, Inserm U1150, Place de Jussieu, Paris, 75005, France. · SpineGuard SA, 10 cours Louis Lumière, Vincennes, 94300, France. · LIB, Sorbonne Université, CNRS UMR 7371, Inserm U1146, 15 rue de l’Ecole de Médecine, Paris, 75006, France.

Abstract

Purpose: Pedicle screw placement is technically demanding in scoliosis treatment. High precision is required due to limited visibility, anatomical variability, and the risk of complications. Although robotic systems assist CT-based planning and execution, they still rely on ionizing intraoperative imaging and complex registration. This study proposes robotic pedicle drilling with real-time preventive breach detection using electrical bioimpedance sensing. Methods: We developed a robotic approach combined with a pedicle-drilling tool equipped with a proprioceptive electrical bioimpedance sensor developed by SpineGuard. A real-time detection algorithm was designed to analyze the electrical bioimpedance signal during drilling and identify abrupt changes in conductivity associated with potential breaches towards the spinal canal. The method operates without external devices or sensors. Results: The ex vivo experiments showed that the proposed method prevented breaches in 100 of the 51 drilling cases. These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before. The ex vivo experiments demonstrated that the proposed method prevented breaches in all 51 drilling cases. Conclusions: This work demonstrates the feasibility of robotic pedicle drilling with electrical bioimpedance sensing for real-time breach prevention. Using only the tool signal, the method eliminates the need for external sensing systems and supports safer pedicle screw placement.

Figures & tables

Explore similar work

CardsList
  1. Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space

    Jul 21, 2026Zicong Wu, Panagiotis Kalozoumis, S. M. Hadi Sadati +8Robotic SystemsColonoscopy

  2. Human-Inspired Framework for Robotic Craniotomy: Integrating Multimodal Fusion and Adaptive Trajectory Adjustment

    Jul 23, 2026Renzhen Le, Xiao Zhang, Di Wu +5Surgical RobotsMultimodal Fusion

  3. Automated Screw Planning for Reduced Pelvic Fractures Based on Statistical Shape Models and Deep Learning

    Sep 29, 2026Yang Gao, Sutuke Yibulayimu, Yanzhen Liu +2Statistical Shape ModelDeep Learning