eess.SYOct 2, 2026

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

Authors: Emad Abukhousa, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos

Organizations: School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA · Electrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia · Interdisciplinary Research Center for Sustainable Energy Systems (IRC-SES), KFUPM, Dhahran 31261, Saudi Arabia

Abstract

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

Figures & tables

Explore similar work

Jun 23, 2026

PROTECT-90: A Fault Dataset for Power System Protection

The increasing interest in data-driven methods for power system protection is accompanied by a lack of standardized, publicly available high-voltage waveform datasets that enable transparent and reproducible evaluation. To address this gap, this paper introduces the PROTECT-90 dataset, an open electromagnetic transient (EMT)-simulated reference benchmark for high-voltage fault studies with consistent digital-fault-recorder-like measurements, publicly released with this work. The dataset comprises 9,022 physically consistent short-circuit simulation episodes generated on a standardized 90 kV double-line topology with systematically documented domain randomization of grid operating points, line parameters, and fault conditions. For each episode, synchronized three-phase voltage and current waveforms are recorded at eight measurement locations and released together with structured, machine-readable metadata describing fault type, fault location, inception time, and operating conditions. All modeling assumptions, parameter ranges, and data-generation procedures are explicitly documented to ensure transparency and cross-study comparability. By combining physically grounded EMT simulation, balanced scenario coverage, and open accessibility, PROTECT-90 establishes a standardized foundation for reproducible benchmarking of protection-oriented signal processing and learning-based methods.
Aug 20, 2026

A Standardized Framework for Machine Learning in Power System Protection

Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.
May 17, 2026

Latency-Aware Deep Learning Benchmark for Real-Time Cyber-Physical Attack and Fault Classification in Inverter-Dominated Power Grids

This work introduces a latency-aware benchmarking framework for evaluating deep learning models in power system anomaly detection using high-fidelity, time-domain signals generated from an industry-grade electromagnetic transient simulator. Eight neural network architectures, ranging from MLPs to Transformers, were systematically evaluated on streaming datasets representing both physical faults and cyber-attacks in inverter-dominated networks. All models successfully classified two representative multi-event sequences in real time with sub-cycle response times below 15 ms. However, although classification decisions occurred within one cycle, the end-to-end inference latency consistently exceeded three cycles, ranging from 50 to 90 ms. These results highlight a critical gap between algorithmic capability and protection-grade deployment, pointing to the need for further optimization and hardware acceleration. The findings establish a reproducible benchmark for sub-cycle anomaly detection and provide guidance for transitioning machine learning methods from research prototypes to real-world protection applications.