cs.CVOct 7, 2026

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

Authors: Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu, Dosik Hwang

Organizations: Yonsei University · Microsoft Research Asia · Korea Institute of Science and Technology

Abstract

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

Figures & tables

Explore similar work

Jun 16, 2026cs.CV

Recover Semantics First, Generate Better: Improved Latent Modeling for 3D MRI Reconstruction and Cross-Contrast Synthesis

Multi-contrast magnetic resonance imaging (MRI) provides complementary information for clinical diagnosis. However, acquiring all MRI sequences is often time-consuming and costly. Recent generative models perform cross-contrast synthesis to address this issue by inferring absent contrasts from the available ones. Nevertheless, synthesizing 3D MRI presents significant challenges. Due to the massive volume sizes, operating directly in the pixel space is computationally prohibitive; therefore, a common approach is to first compress the 3D volumes into a latent space and subsequently train generative models in that space. We observe that existing compression architectures face several critical issues: they under-preserve long-range anatomical coherence, discard clinically meaningful semantics, and rely on optimization objectives that lead to over-smoothed reconstructions. Ultimately, these shortcomings compromise the performance of subsequent generative models. In this work, we propose a semantics-first latent modeling framework for 3D MRI reconstruction and cross-contrast synthesis. Specifically, we introduce a Latent Harmonization Encoder (LHE) to capture global anatomical dependencies, ensuring coherent volumetric representations. To mitigate semantic degradation during latent compression, we further design a Semantic Recovery Block (SRB) that injects high-level priors from a self-supervised semantic teacher, enhancing contrast-aware separability in the latent space. Additionally, we propose an Anatomy-aware Frequency Loss (AFL) to adaptively preserve diagnostically relevant high-frequency structures. Extensive experiments on two public multi-contrast MRI datasets demonstrate consistent improvements in reconstruction fidelity and cross-contrast synthesis quality. Our code is available at https://github.com/script-Yang/RSF.
Aug 5, 2026cs.CV

VoxStruct3D: Structure-Leading Flow Matching for Voxel-Space 3D MRI Synthesis

High-fidelity 3D MRI synthesis requires both globally coherent anatomy and fine-grained voxel-level detail. Although latent diffusion makes volumetric generation tractable, its image autoencoder introduces a reconstruction bottleneck that can limit the fine detail recoverable in the final volume. We present VoxStruct3D, a voxel-space flow-matching framework that directly models full-resolution MRI volumes using a clean-data prediction objective. Its Volumetric Voxel Generator (VVG) combines factorized 3D patch embedding with overlapping upsampling, time-modulated residual refinement, and skip fusion, enabling neighboring tokens to jointly reconstruct shared voxel regions and suppress patch-boundary artifacts. To complement direct voxel-space modeling with an explicit anatomical prior, we further introduce a Structure-First, Image-Follows (SFIF) strategy. A frozen pretrained 3D medical encoder and a StructVAE extract compact structure tokens that preserve dominant anatomy, while a structure-leading schedule keeps their trajectory ahead of the image trajectory. Patch-Aligned RoPE spatially aligns the unequal token grids, and asymmetric attention enforces one-way guidance from structure to image. Experiments on pathological and healthy T1-weighted brain MRI datasets show that VoxStruct3D achieves the strongest overall performance across feature-distribution alignment, sample diversity, and perceptual quality, producing anatomically coherent and visually realistic volumes.
Apr 22, 2026cs.CV

WFM: 3D Wavelet Flow Matching for Ultrafast Multi-Modal MRI Synthesis

Diffusion models have achieved remarkable quality in multi-modal MRI synthesis, but their computational cost (hundreds of sampling steps and separate models per modality) limits clinical deployment. We observe that this inefficiency stems from an unnecessary starting point: diffusion begins from pure noise, discarding the structural information already present in available MRI sequences. We propose WFM (Wavelet Flow Matching), which instead learns a direct flow from an informed prior, the mean of conditioning modalities in wavelet space, to the target distribution. Because the source and target share underlying anatomy and differ primarily in contrast, this formulation enables accurate synthesis in just 1-2 integration steps. A single 82M-parameter model with class conditioning synthesizes all four BraTS modalities (T1, T1c, T2, FLAIR), replacing four separate diffusion models totaling 326M parameters. On BraTS 2024, WFM achieves 26.8 dB PSNR and 0.94 SSIM, within 1-2 dB of diffusion baselines, while running 250-1000x faster (0.16-0.64s vs. 160s per volume). This speed-quality trade-off makes real-time MRI synthesis practical for clinical workflows. Code is available at https://github.com/yalcintur/WFM.