MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping Feedback
Organizations: Department of Mechanical Engineering, National University of Singapore, Singapore · Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, USA · Mechanical Engineering Department, City University of Hong Kong, Kowloon, Hong Kong SAR, and CAS-CityU Joint Laboratory for Robotic Research, City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
Abstract
Robotic grasping and surface exploration benefit from simultaneous measurement of normal and tangential forces and from surface information obtained through contact. Here, we present a compact magnetociliary tactile sensor (MagCilia) that combines a flexible magnetic-cilia structure with a Hall sensor for 3D force sensing. Quasi-static finite element analysis is used to investigate structural deformation and magnetic responses under multidirectional loading. To reconstruct forces from the coupled magnetic channels, we propose causal history fusion regression (CHFR), which combines current magnetic-field measurements with their recent changes. Five-fold cross-validation grouped by calibration record yields root-mean-square errors of 0.40, 0.57, and 0.69 N for Fx, Fy, and Fz, respectively, with corresponding coefficients of determination of 0.93, 0.90, and 0.92. Robotic experiments demonstrate tangential-force-guided gripper adjustment and multi-axis load monitoring under external perturbations. Frequency-domain features of the reconstructed forces distinguish six surface categories with 99.39% accuracy in three-fold cross-validation grouped by acquisition session. An online robotic demonstration additionally identifies all six tested surfaces. These results demonstrate 3D force reconstruction, grasping feedback, and surface recognition using a single compact tactile unit.
Figures & tables
| Sensor | Configuration | Capability | Quantitative performance |
|---|---|---|---|
| [ 17 ] | Magnetized film with Hall sensing | Normal and 1D tangential force | Sensitivity: 0.01 kPa -1 (normal), 0.10–0.27 kPa -1 (tangential) |
| [ 18 ] | Stacked magnetic films with a Hall array | 3D force sensing | Range: 28 N (normal), N (tangential) |
| [ 20 ] | Magnetic-cilia array with a sensor array | Tangential force and direction | Resolution: 0.2 mN |
| [ 21 ] | Soft-magnetic cilia with an induction coil | Weak tangential force sensing | Sensitivity: 10.03%/mN |
| [ 22 ] | Segmented magnetic cilia | Flow and texture sensing | Flow-direction error: |
| [ 23 ] | Magnetic cilia with a single Hall sensor | Normal force and tangential direction | Normal sensitivity: 0.02 N -1 ; |