cs.LGOct 8, 2026

Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathy

Authors: John M. O'Toole, Sean R. Mathieson, Aurel Luca, Soraia Ventura, Sean Griffin, Geraldine B. Boylan, Robert Hogan

Organizations: CergenX Ltd, Cork, Ireland · INFANT Research Centre, University College Cork, Ireland · Department of Paediatrics and Child Health, University College Cork, Ireland

Abstract

Background: Discontinuity in neonatal EEG is a critical marker of brain dysfunction but can be difficult to quantify visually. Inter-burst intervals (IBIs) are a key characteristic of discontinuity, yet their definition does not easily translate to AI detection. Objectives: To introduce low-voltage intervals (LVIs), defined exclusively by amplitude and duration, as a context-independent alternative to IBIs, develop an AI detection method for LVIs, and assess their clinical utility as a marker of brain injury. Methods: We developed a ConvNeXt model to detect LVIs and compared its performance with existing methods. We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden. Results: For training and validation, 654 hours of per-channel EEG from 123 neonates were reviewed and 51,162 LVIs were annotated. On held-out validation, ConvNeXt had an AUC of 0.996 and a Matthews correlation coefficient of 0.926. Model-reader agreement exceeded inter-reader agreement (Δκ=0.025Δκ= 0.025, 95% CI: 0.007 to 0.045, p<0.001p<0.001), attaining expert-level equivalence. On a combined dataset of 444 neonates, percentage LVI showed a strong association with EEG grades (Spearman's ρ=0.801ρ=0.801), a moderate association with HIE grades (ρ=0.384ρ=0.384), a weaker association with seizure burden (ρ=0.244ρ=0.244), and a strong seizure prediction capacity (AUC =0.872=0.872). Conclusion: AI detection of LVIs achieves expert-level equivalence, whereas quantitative features do not. Automated LVI quantification provides a robust clinical biomarker of neonatal encephalopathy associated with background EEG activity, HIE severity, and seizure risk.

Figures & tables

Appendix figures & tables11 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. U-NeXt: General-purpose event detection for neonatal EEG

    Oct 23, 2026Robert Hogan, Sean R. Mathieson, Aurel Luca +4ElectroencephalographyEEG Seizure Detection

  2. Interpretable Multimodal EEG-ECG Framework for Neonatal Seizure Prediction and Patient-Adaptive Transfer Learning

    Nov 18, 2025Sithmini Ranasingha, Agasthi Haputhanthri, Hansa Marasinghe +5EEG Seizure DetectionCross-Subject EEG Decoding

  3. Attention-Enhanced Dual-Branch ConvNeXt-BiLSTM Network for Subject-Independent EEG Seizure Detection

    Aug 25, 2026Maimuna Chowdhury, Sk. Imran HossainEEG Seizure DetectionElectroencephalography