eess.SPOct 11, 2026

Distinguishing Process Change, Instrument Fault and Data-Path Corruption in Streaming Telemetry: A Reference Implementation and Benchmark

Authors: Oleksandr Klymenko

Organizations: Independent Researcher, Poland

Abstract

A reading departs from what a monitoring system expects for one of three reasons: the physical process changed, the instrument is failing, or the value was corrupted between the instrument and the software. The three call for different responses and look alike in a single sample. We state the three-cause problem, prove which pairs of causes one channel cannot separate, and propose a bank of online detectors - a Kalman tracker with CUSUM and EWMA charts on its innovation, a Hampel median with generalized-ESD confirmation, a robust noise statistic with ADWIN, exact-value checks and an optional two-channel complementary filter - combined by a deterministic, inspectable attribution rule. The detectors were merged into a public algorithm library. On 2,942 injected events of thirteen fault types the method detects 96.3% (95% interval 95.7-97.0) at 0.22 false alarms per hour and attributes 91.2% (90.6-91.8) of detected events correctly from one channel and 99.0% (98.6-99.4) with a second, rate channel; from one channel only 2 of 207 detected sensor drifts are attributed to the instrument, as the problem statement predicts. Injected into recorded industrial signals, the same catalogue is detected at 80.8% and attributed correctly at 84.5%, at 3.6 false alarms per hour. On the Skoltech Anomaly Benchmark the method detects 32 of 33 experiments with a median delay of 15 s, at 46 false alarms per hour against 11 for a rolling z-score.

Figures & tables

Explore similar work

Mar 9, 2026

Towards Differentiating Between Failures and Domain Shifts in Industrial Data Streams

Anomaly and failure detection methods are crucial in identifying deviations from normal system operational conditions, which allows for actions to be taken in advance, usually preventing more serious damages. Long-lasting deviations indicate failures, while sudden, isolated changes in the data indicate anomalies. However, in many practical applications, changes in the data do not always represent abnormal system states. Such changes may be recognized incorrectly as failures, while being a normal evolution of the system, e.g. referring to characteristics of starting the processing of a new product, i.e. realizing a domain shift. Therefore, distinguishing between failures and such ''healthy'' changes in data distribution is critical to ensure the practical robustness of the system. In this paper, we propose a method that not only detects changes in the data distribution and anomalies but also allows us to distinguish between failures and normal domain shifts inherent to a given process. The proposed method consists of a modified Page-Hinkley changepoint detector for identification of the domain shift and possible failures and supervised domain-adaptation-based algorithms for fast, online anomaly detection. These two are coupled with an explainable artificial intelligence (XAI) component that aims at helping the human operator to finally differentiate between domain shifts and failures. The method is illustrated by an experiment on a data stream from the steel factory.
Aug 21, 2026

TRACE-C: Rank-Calibrated Relational Anomaly Detection for Multi-Stream Operational Telemetry

Operational telemetry can be jointly anomalous while every individual stream stays inside its familiar range. TRACE-C is an auditable strictly-prior rank-calibrated detector for aligned multi-stream telemetry: same-regime rolling median/MAD residuals feed three window channels -- a maximum normalized local sum, a Gaussian copula-form dependence contrast on robust-z residuals, and a worst standardized AR(1) innovation -- whose channel ranks are Fisher-aggregated and ranked against earlier aggregates. We evaluate six Great Britain grid streams with a January-April 2019 fit, July-December 2019 development evidence, and a 2020 hold-out frozen before inspection. TRACE-C ranks Storm Atiyah first among 2019 test windows, but a disclosed channel ablation attributes that rank to the local channel, not the copula-form channel: copula-only ranks Atiyah 59th. The short 9 August frequency event is ranked far lower by the fused detector (143) than by the temporal channel alone (40), and reconstruction baselines rank it first. In 2020 no window is selected, which is consistent with record-rule saturation rather than an uneventful year; the highest-ranked frozen window was later interpreted as Storm Ellen. Three interpretive limits carry throughout. The resulting p-values are selection quantities, not event probabilities. The copula-form channel is not a literal copula density: the method applies no probability-integral or normal-score transform. Empirical rank counts are diagnostics, not coverage or false-discovery proofs. Every table and figure in this paper is generated from committed machine-readable reports.
Sep 30, 2026

What Streaming Anomaly Detection Finds (and Misses) in Industrial Time Series

EDF relies on continuous monitoring of its power plants to detect anomalies as soon as they occur. Given the absence of a universally optimal streaming method in unsupervised settings, we compare streaming methods with state-of-the-art TSAD models deployed online on a real nuclear power plant dataset. This work also evaluates Automated Anomaly Detection in a streaming context. Results show higher consistency for online TSAD and strong robustness from ensembling strategies.