PET Quantification-Preserving Registration for Longitudinal Whole-Body PSMA PET/CT
Organizations: Helmholtz Munich · Technical University of Munich · Munich Center for Machine Learning · University Medical Center Hamburg-Eppendorf ·
Abstract
We adapt the diffeomorphic coarse-to-fine LapIRN architecture for longitudinal whole-body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method combines affine pre-registration, multi-modal deformable registration, and test-time instance optimization. We further introduce PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG), including Jacobian-based constraints, and a per-structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0% DSC and 6.17 mm HD95, with MTV and TLG errors of 3.3% and 3.3%, respectively, on our evaluation protocol. Code is available at https://github.com/koegl/psmareg.
Figures & tables
| Method | DSC (%) | HD95 (mm) | MTV error (%) | TLG error (%) | NDV (ppm) | Time (s) |
|---|---|---|---|---|---|---|
| Initial | 14.8 ∗ | 30.9 ∗ | – | – | – | – |
| Affine | 52.9 ∗ | 11.7 ∗ | 5.47 | 4.70 | – | 19.1 0.920 |
| ConvexAdam | 63.0 ∗ | 8.41 ∗ | 5.10 | 4.15 | 100 | 22.8 1.06 |
| NiftyReg | 73.3 ∗ | 7.09 ∗ | 4.46 | 8.68 ∗ | 1525 ∗ | 49.7 0.480 |
| Ours (no IO) | 76.5 | 6.65 | 3.22 | 5.08 | 0.00 | 19.5 1.02 |
| Ours (container) | 81.0 | 6.17 | 3.29 | 3.31 | 864 | 89.8 2.69 |
Medical Image Registration
Medical image registration aligns scans across time, patients, or imaging modalities to track anatomy and support diagnosis, treatment, and image-guided procedures.
See all 96 papers