Physical Operating-Condition-Guided Vision-Language Matching for Cavitation Diagnosis in Industrial Pipeline Systems
Authors: Yu Sha, Junqi Tao, Deyu Wang, Horst Stoecker, Domagoj Vnucec, Andreas Widlf, Kai Zhou
Organizations: School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, 518172, China · Frankfurt Institute for Advanced Studies, Frankfurt am Main, 60438, Germany · Institut für Theoretische Physik, Goethe Universität Frankfurt, Frankfurt am Main, 60314, Germany · GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, 64291, Germany · SAMSON AG, Frankfurt am Main, 60314, Germany · School of Artificial Intelligence, The Chinese University of Hong Kong, Shenzhen, 518172, China
Cavitation diagnosis in industrial pipeline systems is challenging because acoustic responses vary substantially with operating conditions, while similar time-frequency patterns may correspond to different cavitation states. To address this issue, we propose a physical operating-condition-guided vision-language matching (POC-VLM) for cavitation diagnosis. POC-VLM first constructs physical operating-condition-aware semantic descriptions by explicitly incorporating sample-specific operating variables into candidate cavitation texts. A time-frequency-conditioned text adaptation module then dynamically aligns these physical semantics with the observed acoustic response, followed by global-local vision-language matching to capture both holistic and localized discriminative patterns. In parallel, a K-nearest neighbours-based non-parametric physical operating-condition prior estimates the physical plausibility of each candidate state and is fused with the vision-language semantic evidence at the decision level. Experiments on three real-world cavitation datasets show that POC-VLM consistently outperforms representative data-driven, multimodal and domain-specific diagnostic methods. Further analyses verify the complementary roles of vision-language semantic matching and physical operating-condition priors, while demonstrating robust performance under varying sampling rates, noise levels and observation durations.
Figures & tables
Figure 1: Overall framework of the proposed POC-VLM for cavitation diagnosis. It combines vision-language semantic matching with a physical operating-condition prior through decision-level evidence fusion.
Figure 2: Schematic view of the test rack at SAMSON AG.
Physical parameters
Types
Ranges
Tolerances
Flow rate
Krohne M950
0 −180m3h−1
±0.9m3h−1
Valve stroke
Sylvac S229
0 −50mm
±0.001mm
Upstream pressure
SAMSON 6054
0 −16bar
±0.09bar
Downstream pressure
SAMSON 6054
0 −16bar
±0.09bar
Medium temperature
SAMSON 5204
-20 −150\SIUnitSymbolCelsius
±0.45\SIUnitSymbolCelsius
Valve structure noise
Vallen VS45-H
20 −450kHz
±63dB
Table 1: Detailed information of various measurement sensors.
Dataset
Operation parameters
Valve stroke ( mm )
Upstream pressure ( bar )
Temperature ( \SIUnitSymbolCelsius )
Cavitation-Short
[15, 13.5, 11.25, 7.5, 3.75, 1.5, 0.75]
[10, 9, 6, 4]
25–50
Cavitation-Long
[60, 55, 45, 30, 25, 15, 6]
[10, 6, 4]
23–52
Cavitation-Noise
15
10
32–39
Table 2: Details of three real-world cavitation datasets for valve operation with various upstream pressures.
Dataset
Training set
Testing set
Cavitation
Non
Cavitation
Non
Choked flow
Constant
Incipient
Choked flow
Constant
Incipient
Cavitation-Short
58( × 66)
75( × 66)
32( × 66)
121( × 66)
14( × 66)
18( × 66)
8( × 66)
30( × 66)
Cavitation-Long
117( × 555)
315( × 555)
55( × 555)
158( × 555)
31( × 555)
81( × 555)
9( × 555)
40( × 555)
Cavitation-Noise
32( × 555)
32( × 555)
32( × 555)
32( × 555)
8( × 555)
8( × 555)
8( × 555)
8( × 555)
Table 3: Details of the training and test sets. (⋅) denotes the number after the sliding window (a window duration of 0.06s , an overlap ratio of 0.25 and 512 CWT scales).
Types
Methods
Cavitation-Short
Cavitation-Long
Cavitation-Noise
Acc.
Pre.
Rec.
F1
Acc.
Pre.
Rec.
F1
Acc.
Pre.
Rec.
F1
Data
ResNet18
89.39
89.40
89.39
88.51
93.35
93.33
93.35
93.33
98.05
98.05
98.05
98.05
ResNet34
89.55
89.71
89.55
88.79
93.38
93.30
93.38
93.32
98.06
98.06
98.06
98.06
ResNet50
89.24
89.24
89.24
88.48
93.44
93.35
93.44
93.36
97.84
97.84
97.84
97.84
DenseNet121
90.11
90.22
90.11
89.45
93.30
93.17
93.30
93.19
98.58
98.58
98.58
98.58
DenseNet161
89.94
89.99
89.94
89.23
93.40
93.23
93.40
93.27
97.76
97.76
97.76
97.76
Table 4: Diagnostic performance comparison of different methods across real-world industrial cavitation datasets.
Types
Methods
Cavitation-Short
Cavitation-Long
Cavitation-Noise
Acc.
Pre.
Rec.
F1
Acc.
Pre.
Rec.
F1
Acc.
Pre.
Rec.
F1
Data
LiftingNet
85.29
82.75
75.89
73.95
88.43
86.31
87.97
87.05
95.86
94.62
95.84
95.20
MIPLCNet
86.57
83.38
77.71
75.00
89.14
87.06
88.18
87.55
96.57
95.78
96.61
96.18
ResNet-APReLU
86.86
84.04
77.89
75.56
90.71
88.83
90.91
89.70
97.29
96.77
97.49
97.12
LSTM-RDRN
87.71
85.42
78.50
76.72
91.14
89.36
91.55
90.32
98.71
98.40
98.53
98.46
Hybrid
HKG-ResNet34
89.71
90.54
78.02
76.74
92.44
88.55
92.21
90.16
99.06
99.06
99.06
99.06
Table 5: Diagnostic performance comparison with domain-specific methods across real-world cavitation datasets.
Figure 3: Normalized confusion matrices of PerceiverIO and POC-VLM across the three real-world cavitation datasets. (a-c) PerceiverIO on Cavitation-Short, Cavitation-Long and Cavitation-Noise, respectively. (d-f) POC-VLM on the corresponding datasets.
Model Variant
Accuracy
Precision
Recall
F1-score
w/o Vision-Language Pathway
0.9104 ± 0.0018
0.8985 ± 0.0048
0.8732 ± 0.0043
0.8800 ± 0.0050
w/o Physical Operating-Condition Prior
0.8859 ± 0.0049
0.8864 ± 0.0044
0.8243 ± 0.0049
0.8384 ± 0.0051
POC-VLM
0.9714 ± 0.0040
0.9694 ± 0.0058
0.9549 ± 0.0017
0.9608 ± 0.0038
Table 6: Ablation results of different model variants of POC-VLM on Cavitation-Short. The results are averaged over three independent runs.
Physical Prior
Textual Description
Accuracy
Precision
Recall
F1-score
✗
Static class
0.8316 ± 0.0031
0.8359 ± 0.0036
0.7248 ± 0.0032
0.7342 ± 0.0025
✗
Dynamic POC-aware
0.8859 ± 0.0049
0.8864 ± 0.0044
0.8243 ± 0.0049
0.8384 ± 0.0051
✓
Static class
0.9422 ± 0.0028
0.9232 ± 0.0027
0.9320 ± 0.0024
0.9272 ± 0.0035
✓
Dynamic POC-aware
0.9714 ± 0.0040
0.9694 ± 0.0058
0.9549 ± 0.0017
0.9608 ± 0.0038
Table 7: Ablation analysis of textual semantic representation and the physical operating-condition prior on Cavitation-Short. The results are averaged over three independent runs.
Figure 4: Ablation and sensitivity analysis of POC-VLM on Cavitation-Short. (a) Window duration, (b) window overlap ratio, (c) number of CWT scales, (d) CLIP visual patch size, (e) number of cross-attention heads and (f) number of P2Tformer layers. The results are averaged over three independent runs.
Figure 5: Analysis of physical operating conditions for POC-VLM on Cavitation-Short. (a) Combination analysis of the 255 non-empty combinations of eight physical operating-condition variables, (b) nearest-neighbour analysis and (c) physical-prior fusion weight analysis. The results are averaged over three independent runs.
Number
Physical Operating Conditions
Evaluation Metrics
Xf
Kv
h
pu
pd
Q
pv
T
Accuracy
Precision
Recall
F1-score
1
✓
0.7297
0.6341
0.6312
0.6262
2
✓
✓
0.9143
0.9248
0.8701
0.8856
3
✓
✓
✓
0.9714
0.9694
0.9549
0.9608
4
✓
✓
✓
✓
0.9714
0.9694
0.9549
0.9608
5
✓
✓
✓
✓
✓
0.9714
0.9694
0.9549
0.9608
Table 8: Best-performing physical operating-condition variable combinations for different numbers of variables on Cavitation-Short.
Figure 6: Generalization and robustness analysis of POC-VLM. (a) Sampling-rate analysis and (b) noise-level analysis on Cavitation-Short, and (c) cross-duration analysis between Cavitation-Short and Cavitation-Long. The results are averaged over three independent runs.
Fault diagnosis identifies, localizes, and explains failures in engineered and computational systems using sensor data, logs, models, and domain knowledge.
School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, 518172, China. · Frankfurt Institute for Advanced Studies, Frankfurt am Main, 60438, Germany. · Key Laboratory of Quark & Lepton Physics and Institute of Particle Physics, Central China Normal University, Wuhan, 430079, China. +4