cs.LGOct 22, 2026

An Agent Architecture with Tools and Memory for Selective Correction of Wrist PPG Heart Rate Estimates

Authors: Xu Wang, Shuhan Yi, Zhen Cheng

Organizations: School of Engineering, The Hong Kong University of Science and Technology, Hong Kong 999077, China · School of Biomedical Engineering, Tsinghua University, Beijing 100084, China

Abstract

Wrist photoplethysmography (PPG) heart rate estimates are vulnerable to motion artifacts, and corrections that reduce mean error can worsen individual windows. We propose an agent architecture with tools and memory around a fixed heart rate estimator. Pulse, motion, and limited historical evidence generate candidate estimates, whose predicted benefits and harms guide selection. An independent risk gate determines whether to retain, correct, or reject each output. We trained the architecture on PPG-DaLiA and tested it on Wrist Exercise, GalaxyPPG, and WildPPG with frozen weights. Across these four public datasets, mean absolute error (MAE), macro-averaged over ten estimators, decreased by up to 44.5%, with the largest reduction on GalaxyPPG. Beneficial and harmful corrections decreased and increased absolute error by more than 1 bpm, respectively. Their ten-estimator macro-averaged proportions ranged from 16.06% to 36.64% and from 1.68% to 6.77%, respectively, across the four datasets. At 60% and 80% target coverage, numerical correction on the same accepted windows contributed more to total error reduction than window selection. We implemented real-time wearable acquisition, Bluetooth reception, and smartphone deployment of a selected estimator and the framework. In backend analysis of four prototype recordings from one participant, ten-estimator macro-averaged MAE decreased from 9.09 to 4.45 bpm without additional rejection. Under the evaluated conditions, the architecture improved average accuracy while quantifying correction benefits and harms, supporting wearable heart rate analysis that considers error, correction risk, and coverage.

Explore similar work

Jun 29, 2026

Physically-Constrained Harmonic Separation for Robust Heart and Respiratory Rate Estimation from Wrist Photoplethysmography

Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.
Jul 29, 2026

PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation

Remote photoplethysmography (rPPG) enables non-contact heart-rate estimation from facial videos, but its weak physiological signal is easily corrupted by motion, illumination changes, occlusion, skin-appearance variation, and device noise. Existing rPPG methods typically rely on a single model to directly predict heart rate or recover pulse waveforms, while different strong estimators may produce conflicting yet individually plausible candidates for the same video. To resolve these conflicts, we propose PhysAgent, an inference-time multi-agent candidate-verification framework. Unlike direct prediction approaches, PhysAgent neither trains a new base rPPG model nor asks Multimodal Large Language Models (MLLMs) to output heart rate directly. In contrast, it treats outputs from multiple base estimators as physiological hypotheses to be verified and uses a lightweight 4B MLLM, Qwen3-VL-4B, to drive multi-agent reasoning over video conditions, signal reliability, and candidate disagreement. A deterministic physiological verifier checks the fusion proposal, and a reproducible numerical fusion process produces the final heart rate. Experimental results on multiple public rPPG benchmarks show that PhysAgent improves fusion stability and reliability across different datasets and source-domain settings, while avoiding the irreproducibility and physiological inconsistency of direct MLLM prediction or unconstrained ensemble fusion. The code will be released soon.
May 18, 2026

Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables

Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.