Organizations: Medical Intelligence and Robotic Cognition (MIRoC) Lab, Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China · Chair for Computer-Aided and Medical Procedures (CAMP), Tehcnical University of Munich, Munich, Germany · Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China · Shenzhen Luohu People’s Hospital, Shenzhen, China · Department of Medical Ultrasonics, Guangdong Provincial People’s Hospital, Guangzhou, China
Objective: To develop a unified vision-language model for prompt-conditioned quantitative ultrasound measurement that addresses the mismatch between continuous measurement targets and discrete token-based numerical prediction. Methods: This article presents HAD-VLM, a hybrid autoregressive-diffusion framework that combines autoregressive text generation with continuous measurement prediction within a shared backbone. Visual prompt tuning adapts the vision encoder to ultrasound images. A diffusion process predicts a five-component representation comprising caliper endpoint coordinates and measurement length. A post-processing strategy combining the proposed coordinate-length consistency mechanism with ensemble prediction is introduced to refine measurement estimates. We evaluate four echocardiographic measurement tasks on EchoNet-LVH, with additional assessments of medical question answering and X-ray vertebral measurement. Results: HAD-VLM achieves mean absolute errors of 1.36, 2.77, 3.05, and 1.16 mm for IVSd, LVIDd, LVIDs, and LVPWd, respectively, reducing errors by 21.4-37.6% relative to the Vicuna-based autoregressive baseline. It also outperforms fine-tuned Qwen3-VL and direct MLP regression across all four tasks. Medical question answering performance is preserved on the evaluated dataset. For X-ray vertebral measurement, HAD-VLM reduces mean absolute error from 11.4 to 6.7 pixels. Conclusion: Integrating autoregressive language generation with diffusion-based continuous prediction improves quantitative medical image measurement while retaining prompt-conditioned task flexibility. Significance: HAD-VLM provides a unified approach to combining language interaction with anatomically grounded numerical prediction for quantitative medical image analysis.
Figures & tables
Fig. 1 : An illustration of the mismatch between continuous anatomical measurements and discrete token-based numerical prediction.
Fig. 2 : Overview of HAD-VLM for prompt-conditioned quantitative ultrasound measurement. The framework comprises (a) an prompt-adapted vision encoder, (b) a projector, (c) a hybrid LLM, and (d) a post-processing module. It integrates autoregressive text generation with diffusion-based continuous measurement prediction via a 5-tuple measurement representation and a coordinate-length consistency mechanism.
Fig. 3 : Illustration of the coordinate-length consistency mechanism with a threshold selection based on validation-set discrepancies.
Models
IVSd (MAD: 1.20)
LVIDd (MAD: 2.97)
LVIDs (MAD: 3.60)
LVPWd (MAD: 1.16)
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
VLM (Vicuna)
1.82
2.54
0.25
0.62
3.62
5.00
0.60
0.82
3.88
4.99
0.65
0.82
1.86
8.43
-12.55
0.15
Fine-tuned Qwen3-VL
1.68
2.44
0.32
0.60
3.71
4.87
0.60
0.79
3.82
5.01
0.64
0.81
1.47
1.95
0.28
0.57
VLM + MLP Regression
1.41
2.00
0.54
0.74
3.00
3.95
0.74
0.86
3.42
4.52
0.71
0.85
1.28
1.67
0.47
0.71
HAD-VLM (ours)
1.36
1.96
0.56
0.75
2.77
3.62
0.78
0.89
3.05
4.00
0.77
0.88
1.16
1.54
0.55
0.74
All MAE, RMSE, and MAD values are reported in mm. Bold values indicate the best reported result for each metric.
TABLE I : Quantitative comparison on four EchoNet-LVH measurement tasks, including IVSd, LVIDd, LVIDs, and LVPWd (MAE: mean absolute error; RMSE: root mean squared error; r : Pearson correlation coefficient; R2 : coefficient of determination; MAD: mean absolute deviation reflecting expert measurement variability [ 15 ] ).
Fig. 4 : Qualitative visualization of three representative prediction patterns.
Split
IVSd
LVIDd
LVIDs
LVPWd
Total
Training set
10265
10312
9859
10254
40690
Validation set
310
309
284
310
1213
Test set
1163
1170
1154
1164
4651
TABLE II : EchoNet-LVH dataset split for the measurement tasks.
Models
IVSd (MAD: 1.20)
LVIDd (MAD: 2.97)
LVIDs (MAD: 3.60)
LVPWd (MAD: 1.16)
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
MAE ↓
RMSE ↓
R2↑
r↑
w/o prompt tuning
1.93
2.80
0.11
0.41
5.07
6.64
0.26
0.58
5.60
7.40
0.22
0.54
1.58
2.08
0.18
0.48
w/o cons. w/o ens.
1.49
2.14
0.47
0.69
3.04
3.98
0.75
0.87
3.31
4.29
0.74
0.86
1.31
1.73
0.42
0.67
w/ cons. w/o ens.
1.46
2.07
0.51
0.72
2.96
3.85
0.75
0.87
3.34
4.41
0.72
0.85
1.23
1.60
0.52
0.73
HAD-VLM (ours)
1.36
1.96
0.56
0.75
2.77
3.62
0.78
0.89
3.05
4.00
0.77
0.88
1.16
1.54
0.55
0.74
w/: with, w/o: without, cons.: coordinate-length consistency, ens.: ensembling strategy. All MAE, RMSE, and MAD values are reported in mm.
TABLE III : Ablation results across four EchoNet-LVH measurement tasks: IVSd, LVIDd, LVIDs, and LVPWd. (MAE: mean absolute error; RMSE: root mean squared error; r : Pearson correlation coefficient; MAD: mean absolute deviation reflecting expert measurement variability [ 15 ] . All MAE, RMSE, and MAD values are reported in mm.)
Task
Training
MAE ↓
RMSE ↓
R2↑
r↑
IVSd
Single-task
1.44
2.01
0.54
0.74
HAD-VLM (ours)
1.36
1.96
0.56
0.75
LVIDd
Single-task
3.69
4.84
0.61
0.80
HAD-VLM (ours)
2.77
3.62
0.78
0.89
LVIDs
Single-task
3.69
4.89
0.66
0.83
HAD-VLM (ours)
3.05
4.00
0.77
0.88
TABLE IV : Comparison of single-task and multi-task training on EchoNet-LVH .
Fig. 5 : Illustration of superior endplate length measurements for the Left: (a) C4 and Right: (b) C5 vertebrae.
Models
F1 ↑
BERT P ↑
BERT R ↑
BERT F1 ↑
VLM (vicuna)
0.298
0.855
0.885
0.869
HAD-VLM (ours)
0.320
0.873
0.891
0.882
Bold values indicate the best reported result for each metric.
TABLE V : Evaluation results on the medical QA dataset [ 30 ] .
Models
Numerical prediction
Absolute errors
VLM (vicuna)
Discrete tokens
11.4 ± 93.9
HAD-VLM (ours)
Continuous diffusion
6.7 ± 5.7
Absolute errors are reported in mean ± std pixels.
Bold values indicate the best reported result.
TABLE VI : Measurement results on the CSXA -derived X-ray dataset.
Computer Aided Medical Procedures (CAMP), TU Munich, Germany · Munich Center for Machine Learning (MCML), Munich, Germany · Zhongshan Hospital, Fudan University, China +1