cs.CVOct 24, 2026

Tracking Is Not Sensing: Artifact-Aware Thermal Video Respiration Estimation in Head-Free Marmosets

Authors: Penghao Wang, Sen Yang, Fenghua Xie, He Wang, Xindong Song

Organizations: Institute of Automation, Chinese Academy of Sciences · School of Artificial Intelligence, University of Chinese Academy of Sciences · State Key Laboratory of Brain Cognition and Brain-inspired Intelligence Technology · Tsinghua Laboratory of Brain and Intelligence, Tsinghua University

Abstract

Continuous physiological monitoring is essential for linking behavior, internal state, and neural activity in neuroscience and translational research. In common marmosets, a key nonhuman primate model for social neuroscience, respiratory rate provides a basic readout of arousal, stress, and physiological regulation. Contact sensors can provide accurate measurements, but they add preparation burden and may interfere with head-free behavioral protocols. Thermal video offers a noncontact alternative by capturing breathing-related temperature changes around the nose and mouth. However, in head-free marmosets, these cues are weak, localized, and easily corrupted by head motion, pose changes, and fur. Here we show that this setting exposes a broader challenge in video-based physiological sensing: visually reliable tracking does not necessarily imply physiologically valid measurement. Using synchronized thermal video and contact respiration recordings, we show that marmoset respiration is recoverable from thermal video but strongly ROI-sensitive. Under head-free motion, visually plausible nasal tracking can still produce traces inconsistent with contact respiration, demonstrating that tracking is not sensing. We therefore estimate respiratory rate from learned temporal signals extracted from thermal clips and introduce Selective Temporal Attenuation Regularization (STAR). STAR selectively attenuates high-motion thermal discontinuities through local temporal imputation during training, regularizing models toward respiration-consistent dynamics while leaving inference unchanged on raw video. Across multiple deep-learning backbones, STAR improves head-free estimation, reaching 2.23 bpm MAE compared with 20.76 bpm for tracked ROI analysis.

Figures & tables

Appendix figures & tables12 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Feb 12, 2026

Thermal Imaging for Contactless Cardiorespiratory and Sudomotor Response Monitoring

Human-machine interfaces in industrial automation need sensing modules that monitor operator actions and physiological state. This is important in factories, vehicles, machinery cabins, and human-robot collaboration, where workload, stress, fatigue, or reduced attention can affect safety. RGB monitoring is limited by low light, shadows, and privacy concerns, while thermal infrared imaging captures skin temperature dynamics without visible illumination. This paper studies thermal video as a contactless computer vision modality for estimating electrodermal activity (EDA), heart rate (HR), and breathing rate (BR), with the goal of supporting adaptive human-machine interfaces and operator-state awareness. We propose a signal-processing pipeline that tracks facial regions, aggregates thermal signals, and separates slow sudomotor trends from faster cardiorespiratory components. HR is estimated using orthogonal matrix image transformation (OMIT) across multiple facial regions, while BR is estimated from nasal and cheek thermal signals using spectral peak detection. We characterize 288 ROI-method configurations against contact references with lag-tolerant metrics using 31 sessions from the public SIMULATOR STUDY 1 (SIM1) driver monitoring dataset. The best fixed EDA configuration reaches a mean absolute correlation of 0.40±0.230.40 \pm 0.23 against palm EDA, with individual sessions reaching 0.890.89. BR estimation achieves 3.1±1.13.1 \pm 1.1 bpm mean absolute error, while HR estimation yields 13.8±7.513.8 \pm 7.5 bpm MAE, limited by the 7.57.5 Hz thermal camera frame rate. The results show that thermal video provides useful respiratory and sudomotor cues, while revealing limitations caused by ROI selection, polarity changes, latency, and subject variability. These findings provide baseline design guidance for thermal computer vision as an auxiliary sensing layer in adaptive industrial HMI systems.
Jun 19, 2026

A Skin-Tone-Aware Dual-Representation Remote Photoplethysmography Framework for Contactless Respiratory Rate Estimation

Respiratory rate is a vital indicator of pulmonary and cardiovascular health, yet conventional methods for estimating respiratory rate are often intrusive due to their contact-based nature. Remote photoplethysmography offers a promising non-contact alternative and has been widely used for heart rate estimation; however, its potential for respiratory rate estimation remains underexplored. Existing methods typically adapt green and chrominance-based projections originally designed for heart rate estimation, which only partially capture respiratory dynamics. Most prior work focuses on the Eulerian representation with fixed or empirically selected RGB projections. To address these gaps, we propose a skin-tone-aware dynamic RGB signal projection that captures respiratory information. To mitigate the sensitivity of the Lagrangian representation to non-respiratory motion, we introduce a denoising network for motion-based remote photoplethysmography signals. We further design a phase-independent contrastive loss that enables Eulerian and Lagrangian representations to collaboratively learn respiratory rate information. We also introduce RR-rPPG, a respiratory-rate facial video dataset with Indian demographic representation. We evaluate the method on RR-rPPG and the publicly available COHFACE dataset, where it consistently outperforms comparison methods and achieves up to a 42.1% reduction in mean absolute error across the evaluated settings. The proposed framework demonstrates the effectiveness of jointly leveraging skin-tone-aware Eulerian and denoised Lagrangian representations for contactless respiratory rate estimation from facial videos. In addition, RR-rPPG contributes a diverse benchmark resource for future research in remote respiratory monitoring. The code and dataset will be made publicly available upon paper acceptance.
Jul 6, 2026

Video-based detection of cessation of breathing in pre-term infants using machine learning

Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control. However, reliable respiratory monitoring in the neonatal intensive care unit (NICU) remains challenging because motion artefacts, sensor displacement, and skin fragility can compromise contact-based measurements. Non-contact video monitoring offers a complementary approach that does not depend on adhesive sensors while providing additional respiratory information. We investigated whether camera-based signals can detect apnoea-related cessation of breathing (COBE) and provide complementary information to routinely acquired physiological signals. Using video and clinical recordings from 30 pre-term infants, respiratory motion was extracted from dynamically tracked torso regions to generate camera-derived time-series signals. Camera-only models were trained using residual network (ResNet) architectures, while hybrid models combined video-derived signals with impedance pneumography (IP), ECG-derived respiration (EDR), and the PPG-derived respiratory envelope. Camera-only models achieved a balanced accuracy of 76.9%, demonstrating the feasibility of non-contact COBE detection. Combining video-derived features with IP improved balanced accuracy to 90.6%, outperforming either modality alone and indicating that video provides respiratory information beyond standard physiological signals. These findings show that video-derived signals contain clinically relevant respiratory features and enhance COBE detection when combined with conventional physiological signals. This supports non-contact video as a complementary modality for automated COBE detection and highlights its potential to improve the robustness of neonatal respiratory monitoring.