cs.CVOct 27, 2026

MRI-to-CT Translation of Spinal Images via Anatomy-Guided Pseudo-Pairing and Adversarial Diffusion

Authors: Eduardo Nieto, Ibai Genua, Davide Scorza, Karen López-Linares

Organizations: Fundación Vicomtech, Basque Research and Technology Alliance (BRTA), Donostia - San Sebastián, Spain · R&D Department, Cyber Surgery, Donostia - San Sebastián, Spain · eHealth Group, Bioengineering Area, Biogipuzkoa Health Research Institute, Donostia - San Sebastián, Spain

Abstract

Magnetic Resonance Imaging (MRI) is routinely used to diagnose spinal disorders, but surgical planning often requires Computed Tomography (CT) for better visualization of vertebral bone anatomy. Synthesizing CT from MRI could avoid additional radiation exposure and streamline preoperative assessment. We propose a three-stage framework for spine MRI-to-CT synthesis. First, an anatomy-guided vertebral matching system identifies similar sagittal MRI and CT slices using spine segmentations and aligns them through rigid registration, creating pseudo-paired data from unpaired scans. Second, these pairs train an adversarial diffusion model for MRI-to-CT translation. Third, synthesized slices are assembled into 3D volumes and refined by a network that improves inter-slice continuity and structural coherence. The framework was trained on over 10,000 unpaired sagittal MRI and CT slices and evaluated on 1,911 slices from 83 MRI volumes spanning all spinal regions. Assessment combined distribution-based measures with vertebral segmentation metrics. Compared with diffusion alone, the proposed approach increased binary 3D vertebral Dice from 0.666 to 0.739. Volumetric post-processing reduced visible discontinuities between stacked slices and improved vertebral coherence in axial and coronal views. Combining anatomy-guided pseudo-pairing, adversarial diffusion and 3D refinement improves spine MRI-to-CT synthesis. Vertebral matching primarily enhanced anatomical alignment and fidelity, while volumetric refinement improved 3D consistency. These findings support further development of MRI-derived CT-like visualization for preoperative planning, particularly to preserve fine intensity details while maintaining volumetric coherence.

Figures & tables

Explore similar work

Mar 30, 2026

MRI-to-CT synthesis using drifting models

Accurate MRI-to-CT synthesis could enable MR-only pelvic workflows by providing CT-like images with bone details while avoiding additional ionizing radiation. In this work, we investigate recently proposed drifting models for synthesizing pelvis CT images from MRI and benchmark them against convolutional neural networks (UNet, VAE), a generative adversarial network (WGAN-GP), a physics-inspired probabilistic model (PPFM), and diffusion-based methods (FastDDPM, DDIM, DDPM). Experiments are performed on two complementary datasets: Gold Atlas Male Pelvis and the SynthRAD2023 pelvis subset. Image fidelity and structural consistency are evaluated with SSIM, PSNR, and RMSE, complemented by qualitative assessment of anatomically critical regions such as cortical bone and pelvic soft-tissue interfaces. Across both datasets, the proposed drifting model achieves high SSIM and PSNR and low RMSE, surpassing strong diffusion baselines and conventional CNN-, VAE-, GAN-, and PPFM-based methods. Visual inspection shows sharper cortical bone edges, improved depiction of sacral and femoral head geometry, and reduced artifacts or over-smoothing, particularly at bone-air-soft tissue boundaries. Moreover, the drifting model attains these gains with one-step inference and inference times on the order of milliseconds, yielding a more favorable accuracy-efficiency trade-off than iterative diffusion sampling while remaining competitive in image quality. These findings suggest that drifting models are a promising direction for fast, high-quality pelvic synthetic CT generation from MRI and warrant further investigation for downstream applications such as MRI-only radiotherapy planning and PET/MR attenuation correction.
Mar 13, 2026

A Systematic Benchmark of GAN Architectures for MRI-to-CT Synthesis

The translation from Magnetic resonance imaging (MRI) to Computed tomography (CT) has been proposed as an effective solution to facilitate MRI-only clinical workflows while limiting exposure to ionizing radiation. Although numerous Generative Adversarial Network (GAN) architectures have been proposed for MRI-to-CT translation, systematic and fair comparisons across heterogeneous models remain limited. We present a comprehensive benchmark of ten GAN architectures evaluated on the SynthRAD2025 dataset across three anatomical districts (abdomen, thorax, head-and-neck). All models were trained under a unified validation protocol with identical preprocessing and optimization settings. Performance was assessed using complementary metrics capturing voxel-wise accuracy, structural fidelity, perceptual quality, and distribution-level realism, alongside an analysis of computational complexity. Supervised Paired models consistently outperformed Unpaired approaches, confirming the importance of voxel-wise supervision. Pix2Pix achieved the most balanced performance across districts while maintaining a favorable quality-to-complexity trade-off. Multi-district training improved structural robustness, whereas intra-district training maximized voxel-wise fidelity. This benchmark provides quantitative and computational guidance for model selection in MRI-only radiotherapy workflows and establishes a reproducible framework for future comparative studies. To ensure the reproducibility of our experiments we make our code public, together with the overall results, at the following link:https://github.com/arco-group/MRI_TO_CT.git
Sep 12, 2026

TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT

Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CBCT) images. Materials and Methods: In this retrospective technical study, the dataset was assembled between 2020 and 2026 from SynthRAD challenge data, four prostate cohorts, and BIC-MAC. After registration quality control, 1450 of 1800 public challenge pairs were retained; 350 were excluded for insufficient registration quality or major source/CT mismatch. The corpus also included 84 additional prostate MRI/CT and 60 external BIC-MAC MRI/CT cases. Three 5-fold model families were evaluated with image-domain, anatomy-aware, registration-based, and uncertainty metrics. Age and sex were not consistently available across public datasets. Results: The released MRI-to-CT model achieved an overall MAE of 67.49 HU, SSIM of 0.920, and PSNR of 29.28 dB. The CBCT-to-CT model achieved an overall MAE of 53.55 HU, SSIM of 0.939, and PSNR of 32.09 dB. The unified model maintained similar performance on MRI inputs (MAE, 67.68 HU) and CBCT inputs (MAE, 54.22 HU). On external BIC-MAC data, MRI-to-CT MAE was 100.91 HU without fine-tuning and 62.21 HU after fine-tuning. Conclusion: TotalSynth provides reusable MRI- and CBCT-based CT synthesis models with broad anatomical coverage, while external evaluation highlights the need for local validation and optional fine-tuning under domain shift.