eess.IVOct 30, 2026

Interpretable Multiple-Instance Learning of Glomerular Pathomics and Subtype Ratios for eGFR Classification

Authors: Tianyu Shi, Yuechen Yang, Leiyue Zhao, Daniel Reisenbüchler, Jing Jin, Thangamani Muthukumar, Kenji Ikemura, Mert R. Sabuncu, 

Organizations: Sichuan University, Chengdu, 610065, CN · Vanderbilt University, Nashville, TN, 37235, USA · Johns Hopkins University, Baltimore, MD 21218, USA · University of Regensburg, Regensburg, Bavaria 93053, DE · 

Abstract

Chronic kidney disease is characterized by structural alterations in renal tissue and progressive loss of kidney function. While glomerular subtype ratios provide a compact and clinically meaningful summary of glomerular composition, representing pathomic information using whole-slide image (WSI)-level mean values diminishes glomerulus-level heterogeneity and the contribution of less prevalent patterns. In this proof-of-concept study, we investigated whether modeling individual glomeruli using multiple-instance learning (MIL) could provide complementary information to conventional subtype ratios for estimated glomerular filtration rate (eGFR) classification. We analyzed 162 kidney-biopsy WSIs from 162 patients, categorizing renal function as eGFR < 60 or >= 60 mL/min/1.73 m^2. Quantitative size, shape, intensity, and texture features were extracted from segmented glomeruli, representing each patient as a bag of glomerular instances. An attention-based MIL model was trained to aggregate these heterogeneous pathomic profiles. We evaluated subtype ratios, pathomics, and their combination using ABMIL, with a mean-pooled multilayer perceptron baseline. In five-fold cross-validation, the subtype-ratio-only model achieved an AUC of 0.7262 +/- 0.0596. MIL using pathomics alone achieved an AUC of 0.7362 +/- 0.0788, whereas integrating pathomics with subtype ratios produced the highest mean AUC of 0.7630 +/- 0.0665. SHapley Additive exPlanations (SHAP) were used to examine individual feature contributions. These results demonstrate that MIL-based pathomics can complement established glomerular subtype ratios by capturing additional glomerulus-level information for quantitative kidney-biopsy analysis.

Figures & tables

Explore similar work

Mar 3, 2026

GloPath: An Entity-Centric Foundation Model for Glomerular Lesion Assessment and Clinicopathological Insights

Glomerular pathology is central to the diagnosis and prognosis of renal diseases, yet the heterogeneity of glomerular morphology and fine-grained lesion patterns remain challenging for current AI approaches. We present GloPath, an entity-centric foundation model trained on over one million glomeruli extracted from 14,049 renal biopsy specimens using multi-scale and multi-view self-supervised learning. GloPath addresses two major challenges in nephropathology: glomerular lesion assessment and clinicopathological insights discovery. For lesion assessment, GloPath was benchmarked across three independent cohorts on 52 tasks, including lesion recognition, grading, few-shot classification, and cross-modality diagnosis-outperforming state-of-the-art methods in 42 tasks (80.8%). In the large-scale real-world study, it achieved an ROC-AUC of 91.51% for lesion recognition, demonstrating strong robustness in routine clinical settings. For clinicopathological insights, GloPath systematically revealed statistically significant associations between glomerular morphological parameters and clinical indicators across 224 morphology-clinical variable pairs, demonstrating its capacity to connect tissue-level pathology with patient-level outcomes. Together, these results position GloPath as a scalable and interpretable platform for glomerular lesion assessment and clinicopathological discovery, representing a step toward clinically translatable AI in renal pathology.
Sep 16, 2026

Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology

Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of 0.926±0.0130.926\pm0.013. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.
Nov 15, 2025

From Classification to Cross-Modal Understanding: Leveraging Vision-Language Models for Fine-Grained Renal Pathology

Fine-grained glomerular subtyping is essential for kidney biopsy interpretation, yet it presents a harder setting than the broad organ- or disease-level recognition tasks commonly used in vision-language model (VLM) evaluation. In this task, all categories arise within the same renal microanatomic unit, and clinically meaningful subtypes often differ by subtle, overlapping, and continuum-like morphological cues. Clinically valuable labels are also scarce, making fully supervised image-only paradigms difficult to translate to practice. Although VLMs are promising for data-efficient pathology learning, it remains unclear how their cross-modal representations should be adapted and evaluated for such within-structure discrimination under realistic few-shot constraints. To our knowledge, this study establishes the first fine-grained renal pathology benchmark for few-shot VLM adaptation and systematically examines how supervision level, model design, and adaptation strategy shape both classification performance and multimodal representation structure. Beyond accuracy, AUC, and F1, we assess image-text alignment, positive-negative similarity separation, embedding geometry, and calibration (ECE), asking when performance gains reflect more reliable cross-modal understanding. Across renal pathology cohorts, additional supervision consistently improves discrimination, but reliable adaptation is not explained by alignment alone; stronger performance is associated with larger class separation, more coherent embedding organization, and better awareness of confidence-related failure modes under domain variation. Within this retrospective two-cohort evaluation, these findings move assessment beyond coarse classification and accuracy alone and provide comparative evidence to inform model selection and future translational validation. Code: https://github.com/ddrrnn123/glo-vlms