cs.CVNov 1, 2026

Learning from high-resolution 2D images to reconstruct 3D microstructures

Authors: Wenbo Sui, Lars P. Mikkelsen, Jens W. Andreasen, Daniel Lichau, Harold Phelippeau, Philip J. Withers

Organizations: Thermo Fisher Scientific, Bordeaux, 33800, France. · DTU Energy, Technical University of Denmark, Kgs. Lyngby, 2800, Denmark. · DTU Wind, Technical University of Denmark, Roskilde, 4000, Denmark. · Henry Royce Institute, Department of Materials, University of Manchester, Manchester, M13 9PL, United Kingdom.

Abstract

High-resolution three-dimensional (3D) microstructure characterization remains difficult to undertake at scale because volumetric imaging at the required spatial resolution is expensive, time-consuming or destructive. In many settings, however, fine-resolution two-dimensional (2D) imaging and lower-resolution volumetric measurements are both readily available. We introduce a Privileged Cross-modal Relational Distillation (PCRD) framework that leverages fine-resolution 2D observations during training to improve specimen-specific 3D reconstruction from lower-resolution volumetric imaging alone. We demonstrate PCRD on pultruded carbon fiber-reinforced polymer composites, using scanning electron microscopy as the privileged modality and micro-CT as the inference input. The framework transfers spatial organization by matching similarity distributions defined around corresponding spatial anchors in the teacher and student representations, avoiding direct alignment of heterogeneous feature vectors. In 2D cross-sectional reconstruction, PCRD improves mAP by 1.66 percentage points over direct micro-CT training. Independent 3D validation against high-resolution synchrotron X-ray CT data shows close agreement in fiber volume fraction, diameter and local spacing. The PCRD reconstruction matches 89.97% of the reference fiber centerline length, compared with 75.08% for the interpolated low-resolution volume.

Figures & tables

Explore similar work

Jun 18, 2026

Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation

Generating high-resolution 3D CT volumes with fine details remains challenging due to substantial computational demands and optimization difficulties inherent to existing generative models. In this paper, we propose the Pixel-Level Residual Diffusion Transformer (PRDiT), a scalable generative framework that synthesizes high-quality 3D medical volumes directly at voxel-level. PRDiT introduces a two-stage training architecture comprising 1) a local denoiser in the form of an MLP-based blind estimator operating on overlapping 3D patches to separate low-frequency structures efficiently, and 2) a global residual diffusion transformer employing memory-efficient attention to model and refine high-frequency residuals across entire volumes. This coarse-to-fine modeling strategy simplifies optimization, enhances training stability, and effectively preserves subtle structures without the limitations of an autoencoder bottleneck. Extensive experiments conducted on the LIDC-IDRI and RAD-ChestCT datasets demonstrate that PRDiT consistently outperforms state-of-the-art models, such as HA-GAN, 3D LDM and WDM-3D, achieving significantly lower 3D FID, MMD and Wasserstein distance scores.
Mar 27, 2026

Conditional Diffusion for 3D CT Volume Reconstruction from 2D X-rays

Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited availability. Standard chest X-rays are cost-effective and widely accessible, but provide only 2D projections with limited pathological information. Reconstructing 3D CT volumes from 2D X-rays could markedly increase diagnostic accessibility, yet existing methods rely predominantly on synthetic X-ray projections, limiting clinical generalization. We propose AXON, a multi-stage diffusion-based framework that reconstructs 3D CT volumes directly from real X-rays with substantially improved fidelity over existing approaches. AXON follows a coarse-to-fine paradigm: a Brownian Bridge diffusion model first captures global anatomical structure, and a ControlNet-guided refinement stage then enhances local intensity detail and anatomical realism. To alleviate the depth ambiguity inherent in 2D-to-3D reconstruction, AXON incorporates bi-planar X-ray views, enabling more accurate spatial reasoning and structural recovery. A dedicated super-resolution module further increases the spatial resolution of the generated volumes. Experiments on public and external datasets show that AXON consistently surpasses state-of-the-art approaches while generalizing across diverse clinical distributions. At our highest-resolution bi-planar setting, AXON achieves an 11.9% improvement in PSNR and an 11.0% increase in SSIM over the strongest baseline evaluated at that resolution. In the 1283128^3 single-planar setting, it maintains a lead of 7.8% in PSNR on LIDC-IDRI, with larger margins on the external clinical dataset of 8.0% in PSNR and 16.9% in SSIM. Our code is available at https://github.com/ai-med/AXON/.
May 20, 2026

HyDAR-Pano3D: A Hybrid Disentangled Anatomical Recovery Framework for Panoramic-to-3D Reconstruction

Panoramic radiograph (PR) is fundamentally used in routine dental care, but it inherently provides only a two-dimensional (2D) projection of complex three-dimensional (3D) craniofacial anatomy. Most existing learning-based methods attempt to computationally recover this 3D information by directly regressing native cone-beam computed tomography (CBCT) volumes from PR. However, this direct mapping requires the model to simultaneously learn common anatomical structures and patient-specific morphological variations. This entangled formulation makes the ill-posed 2D-to-3D inverse problem highly ambiguous, often producing over-smoothed reconstructions with blurred anatomical boundaries. To address this, we propose HyDAR-Pano3D, a two-stage framework that reformulates PR-to-CBCT reconstruction as a disentangled anatomical recovery problem. In Stage 1, a dual-encoder network integrates radiographic features with SAM-derived semantic priors to reconstruct an arch-normalized canonical volume. In Stage 2, an Anatomical Restoration Network predicts a prior-constrained structured deformation field to map this canonical volume back to the native space, restoring individual morphological variations. Experiments on three large-scale datasets show that HyDAR-Pano3D significantly outperforms baseline methods (p<0.05p < 0.05), achieving a 25.76 dB PSNR, 85.70% SSIM, and an 83.83% overall anatomical Dice score. The synthesized volumes successfully support downstream segmentation of whole teeth (82.4% Dice) and the inferior alveolar canal (72.2% Dice), demonstrating that our disentangled approach preserves clinically relevant structures to enable robust anatomy-aware assessment when CBCT data is unavailable.