Large Language Models (LLMs) are increasingly used in medical question answering (QA) systems. While recent works aim at incrementally improving the downstream task accuracy, an empirical estimation of the models' energy consumption and the associated carbon footprints is often overlooked. In this study, we demonstrate how practitioners can estimate energy consumption and arrive at reliable emission estimates for medical QA tasks available in the OpenMedical-LLM leaderboard by investigating 13 LLMs from 3 model families ranging from 270M to 14B parameters. We discuss how one can critically interpret energy versus accuracy trade-offs for a set of models for a given task. With this work, we underline that reporting disjoint energy and accuracy metrics alone does not suffice for careful trade-off assessments, but it also demands systematic construction and interpretation of joint trade-off metrics. We envisage such studies aiding practitioners in adopting better and more efficient models for their task and helping them become active participants in building sustainable LLM pipelines.
Figures & tables
Figure 1: Example Pareto-optimal Frontier.
Model
Accuracy ( ↑ )
Energy (kWh) ( ↓ )
CO2 Emission (kg) ( ↓ )
Pre-trained
Fine-tuned
Pre-trained
Fine-tuned
Pre-trained
Fine-tuned
qwen3-0.6b
48.73 ± 3.33
49.52 ± 3.33
0.022
0.031
0.008
0.012
qwen3-1.7b
54.83 ± 3.29
62.23 ± 3.18
0.023
0.036
0.009
0.014
qwen3-4b
68.56 ± 3.08
74.21 ± 2.75
0.04
0.054
0.015
0.02
qwen3-8b
67.13 ± 3.00
76.89 ± 2.65
0.066
0.064
0.025
0.024
qwen3-14b
74.73 ± 2.74
81.03 ± 2.45
0.077
0.089
0.029
0.034
Table 1: Accuracy, Energy Consumption and CO2 Emission Results
Figure 2: Accuracy and CO2 Emissions versus Model Size
Model
Relative Gain
Relative Costs
Family
(Accuracy)
(Energy)
Qwen3
+64%
+187%
Gemma2
+34%
+95%
Gemma3
+134%
+146%
Llama3
+61%
+186%
Table 2: Comparison of relative accuracy gains versus relative energy costs
Figure 3: Interpreting Energy-Accuracy Trade-offs with Pareto-optimal frontier (left) and CIRC rating (right).
Appendix figures & tables5 assets
Supplementary material from the paper’s appendix.
Appendix
Dataset
Type
# Train
# Validation
# Test
Evaluation
Samples
Samples
Samples
Metric
MedQA
Open MCQA
10178
1272
1273
log-likelihood over
A / B / C / D
MedMCQA
Open MCQA
18000
4183
2000
log-likelihood over
A / B / C / D
PubMedQA
Closed MCQA
900
50
500
log-likelihood over
Appendix
Table 3: Datasets included in Open Medical-LLM Leaderboard
Model
Runtime
Energy
CO2 Emission
(s)
(kWh)
(kg)
qwen3-0.6b
2767.698
0.255
0.097
qwen3-1.7b
3704.089
0.353
0.134
qwen3-4b
10920.611
1.071
0.408
qwen3-8b
20619.091
1.986
0.756
qwen3-14b
27956.034
2.752
1.048
Appendix
Table 4: Estimates of energy consumption and CO2 emission for fine-tuning runs