cs.CVNov 4, 2026

3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification

Authors: Yanfan Zhu, Junchao Zhu, Ruining Deng, Shilin Zhao, Yu Wang, Yaohong Wang, Yuechen Yang, Chongyu Qu, 

Organizations: Vanderbilt University, Nashville TN 37235, USA · Weill Cornell Medicine, New York, NY 10021, USA · Vanderbilt University Medical Center, Nashville TN 37232, USA · UT MD Anderson Cancer Center,TX 77030, USA

Abstract

Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.

Figures & tables

Explore similar work

Oct 30, 2026

Interpretable Multiple-Instance Learning of Glomerular Pathomics and Subtype Ratios for eGFR Classification

Chronic kidney disease is characterized by structural alterations in renal tissue and progressive loss of kidney function. While glomerular subtype ratios provide a compact and clinically meaningful summary of glomerular composition, representing pathomic information using whole-slide image (WSI)-level mean values diminishes glomerulus-level heterogeneity and the contribution of less prevalent patterns. In this proof-of-concept study, we investigated whether modeling individual glomeruli using multiple-instance learning (MIL) could provide complementary information to conventional subtype ratios for estimated glomerular filtration rate (eGFR) classification. We analyzed 162 kidney-biopsy WSIs from 162 patients, categorizing renal function as eGFR < 60 or >= 60 mL/min/1.73 m^2. Quantitative size, shape, intensity, and texture features were extracted from segmented glomeruli, representing each patient as a bag of glomerular instances. An attention-based MIL model was trained to aggregate these heterogeneous pathomic profiles. We evaluated subtype ratios, pathomics, and their combination using ABMIL, with a mean-pooled multilayer perceptron baseline. In five-fold cross-validation, the subtype-ratio-only model achieved an AUC of 0.7262 +/- 0.0596. MIL using pathomics alone achieved an AUC of 0.7362 +/- 0.0788, whereas integrating pathomics with subtype ratios produced the highest mean AUC of 0.7630 +/- 0.0665. SHapley Additive exPlanations (SHAP) were used to examine individual feature contributions. These results demonstrate that MIL-based pathomics can complement established glomerular subtype ratios by capturing additional glomerulus-level information for quantitative kidney-biopsy analysis.
Aug 4, 2026

Beyond Isotropic Assumptions: Continuity-Constrained Segmentation and GPU Morphometry for Nanoscale GBM Analysis

Confocal microscopy of optically cleared and swelled tissue resolves complex biological structures in 3D, but such acquisitions are highly anisotropic: along the under-sampled axial direction the structure can appear discontinuous, hampering reconstruction and automated quantitative analysis. The usual remedy upsamples the axial dimension to an isotropic volume before training a segmentation model, which requires dense annotations in the upsampled space, a prohibitive labeling burden. We present an end-to-end, GPU-accelerated framework that overcomes this without additional annotations. The model is trained on the native acquisition volume; random rotation of training patches leverages the well-resolved lateral plane to supply the missing axial information, and a z-axis continuity loss keeps neighboring slices consistent. We adapt both a convolutional (3D U-Net) and a transformer (SwinUNETR) backbone, aggregate overlapping patches by Gaussian consensus, and compute point-spread-function-corrected membrane thickness by ray-surface intersection on the GPU. We apply the method to the glomerular basement membrane (GBM), a thin, highly convoluted part of the kidney's filtration barrier that grows more irregular in disease. Segmentation accuracy matches inter-expert agreement. Continuity-aware training improves reconstruction smoothness and suppresses a periodic terracing artifact at minimal accuracy cost. We quantify GBM thickness across the reconstructed 3D surface and capture disease-related thickening, enabling fully automated anisotropic 3D morphometry of biological structures without dense volumetric labels or image restoration.
Sep 16, 2026

Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology

Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of 0.926±0.0130.926\pm0.013. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.