cs.CVNov 5, 2026

GMD-Mamba: Lightweight 3D Medical Image Segmentation Using a Grouped Multi-Directional Mamba

Authors: Rahim Ullah, Hasan Abbas, Hazrat Ali, Syed Waqar Nabi

Organizations: School of Computing, University of Glasgow, Glasgow, United Kingdom · James Watt School of Engineering, University of Glasgow, Glasgow, United Kingdom · School of Computing, Data and Mathematical Sciences, University of Stirling, Stirling, United Kingdom

Abstract

Mamba has the capability to capture global context in linear time for 3D medical image segmentation. However, existing methods employ Mamba with full-width directional scans at every resolution, keeping the model large (64-138M parameters and high FLOPs). We propose Grouped Multi-Directional (GMD) Mamba, a lightweight network based on the GMD scan that divides input channels CC into groups GG and flattens each group in different directions in one pass. This gives multi-directional context at O(C2/G)O(C^2/G) instead of O(K⋅C2)O(K \cdot C^2), where KK is the number of scan directions. Additionally, we employ Mamba only at the deepest encoder stages, resulting in 19.2M parameters. On BraTS2023, it achieves the best average Dice of 92.0% and the lowest HD95 of 2.7 at ∼\sim1/7 the parameters of SegMamba-V2. For model validation, we also ran experiments on the MSD Spleen dataset, achieving competitive performance. The implementation details and code are publicly available at https://github.com/2802990u/GMD-Mamba.

Figures & tables

Explore similar work

May 29, 2026

BiSegMamba: Efficient Bidirectional Tri-Oriented Mamba for 3D Medical Image Segmentation

Accurate 3D medical image segmentation requires both long-range volumetric context and fine boundary preservation. CNN-based methods have limited global dependency modeling, while Transformer-based models are often computationally expensive for dense 3D inputs. Recent Mamba-based methods provide an efficient alternative, but existing volumetric designs still depend on repeated high-resolution scanning, forward-only sequential modeling, and fixed directional summation, causing high cost, scan-order bias, and suboptimal directional aggregation. We propose BiSegMamba, an efficient bidirectional tri-oriented Mamba network for 3D medical image segmentation. BiSegMamba follows a compact-to-detail design, where a progressive compacting stem (PCS) enables efficient latent-space reasoning while retaining shallow high-resolution features for reconstruction. A multi-scale spatial mixer (MSSM) captures local anatomical patterns in early stages, and the proposed bidirectional tri-oriented Ortho Mamba (Bi-ToOM) block models long-range dependencies from multiple orthogonal views using jointly processed forward and backward scan sequences. Adaptive directional fusion (ADF) learns input-dependent channel-wise weights across scan orientations, replacing fixed summation with orientation-aware fusion. Experiments on a collected carotid CTA dataset and three public benchmarks, BraTS2023, ACDC, and AMOS-CT, show that BiSegMamba generalizes well across vascular, cardiac, brain tumor, and abdominal multi-organ segmentation tasks. Compared with SegMamba-V2, BiSegMamba achieves slightly better performance on BraTS2023 and clear improvements on ACDC and the carotid dataset, while reducing computational cost by up to 77.9% FLOPs, demonstrating a strong accuracy-efficiency balance for general 3D medical image segmentation.
Sep 22, 2026

GAD-MambaUNet: Direction-Group Mamba with Gradient-Adaptive DINOv3 Distillation for Lightweight Medical Image Segmentation

In this paper, we proposed GAD-MambaUNet, a lightweight medical image segmentation network that combines efficient local modeling, direction--group state-space interaction, and training-time foundation-model supervision. To improve contextual modeling in compact segmentation networks, we introduced Direction-Group Graph Selective Scan (DG-GSS), which treated scan-direction and channel-group responses as graph nodes and enabled structured information exchange before multi-directional fusion. We further incorporated DINOv3-GAD supervision, where a frozen DINOv3 teacher provided semantic guidance during training, and Gradient-Adaptive Distillation dynamically regulated the distillation strength. GAD-MambaUNet achieves a favorable accuracy--efficiency balance compared with representative lightweight and general segmentation methods. Ablation studies further verify the effectiveness of DG-GSS and training-time DINOv3-GAD supervision. In future work, we will explore more flexible teacher--student alignment strategies and extend the proposed framework to more diverse medical segmentation scenarios, such as multi-class and multi-modal segmentation tasks.
Jul 21, 2026

DAMamba-UNet3D: A Parameter-Efficient Mamba State Space U-Net with Dynamic Adaptive Scan for 3D Medical Image Segmentation

We propose parameter-efficient SSM-based U-Net architectures for 3D medical image segmentation. Convolutional U-Nets afford O(n) local mixing per layer but lack explicit global context; transformers provide global reasoning at O(n^2) cost in sequence length nn. State-space models (SSMs), such as Mamba, offer O(n)O(n) global propagation per block. Yet, existing medical SSM segmenters rely on fixed scan patterns and large parameter budgets. Dynamic Adaptive Scan (DAS), which learns data-dependent reordering before selective scan, has not been applied to medical imaging or extended to 3D volumes. We propose DAMamba-UNet3D, a hybrid encoder-decoder that integrates tri-plane 3D-DAS blocks at encoder stages E2-E4 while retaining convolutions elsewhere (~5.3M parameters). On BraTS 2020 five-fold cross-validation, DAMamba-UNet3D achieves mean Dice 0.815+/-0.013 (full-volume per-case evaluation) at ~13x lower parameter cost than SegMamba (0.824+-0.014, ~70M). At comparable scale, DAMamba-L (~70M), a wide DAS-native variant with encoder-only DAMamba and a convolutional bottleneck, reaches 0.829+-0.012, surpassing retrained SegMamba by 0.5pt. Component ablations show that encoder-only DAS placement is critical as bottleneck and decoder SSM blocks lower Dice. Together, the results suggest that learned tri-plane DAS in a hybrid U-Net is competitive with, and under our large-scale design may improve upon, SegMamba's fixed Tri-orientated Mamba (ToM) scanning on BraTS 2020. Code: https://github.com/marafathussain/DAMamba-UNet3D.